Physical activity monitoring in healthy adults

Moorhead, A; Liddle, D; Hurley-Osing, D; Hager-Ross, C; Sundelin, G; Baxter, D; McDonough, S

World Congress of Physiotherapy

PURPOSE: Physical activity is beneficial for health and well-being and is commonly measured using a range of physical activity monitors. The aim of this study was to determine the validity and reliability of the activPAL™ activity monitor to measure physical activity in a laboratorybased setting. RELEVANCE: There is currently no universally accepted benchmarking for measuring physical activity in patients with chronic conditions such as low back pain. Therefore the use of activity monitors will more accurately reflect exercise adherence and patterns of activity in clinical populations. PARTICIPANTS: Twenty-four healthy participants (12 males; 12 females) were recruited (age 25.5±2.2; BMI 21.8±2.2). Ethical approval was obtained from the School of Health Sciences Filter Committee, University of Ulster, U.K. METHODS: In an experimental laboratory based study, the participants participated on two occasions, one week apart. The participants worn the activPAL™ on their thigh and conducted a defined and timed (2 minutes) set of activities. The activities were as follows: sitting at a computer; lying on a treatment bench; walking/jogging on a treadmill at 3.2, 4.5 (with and without incline), 8 km/h; cycling on an exercise bike at 45, 60, 75 rpm; walking at normal pace and controlled speed on flat ground; and stair walking. The concurrent validity was tested by comparing the time for each defined activity, e.g. lying/sitting, as recorded by the activPAL™ with those periods of activity measured by an independent observer at the time of recording and afterwards via video recording. An independent observer recorded the number of steps to compare with those recorded by the activPAL™. ANALYSIS: Data was analyzed using the Statistical Package for the Social Sciences version 11.0 (SPSS, Chicago, IL, USA). Descriptive statistics was conducted for the demographic data and each of the variables. T-tests were used to examine the differences between the variables. The reliability of the activPAL™ was tested using the limits of agreement test. RESULTS: The number of steps for each activity recorded by the activPAL™, observer and video recording were not significantly different expect for jogging on the treadmill at 8.0 km/h (P = 0.000) and walking on a treadmill with and without incline at 4.5 km/h (P = 0.000). The time spent sitting/lying and walking recorded by the activPAL™ did not differ significantly from the video recording. The inter-monitor reliability was excellent for the activPAL™, as there were no significant differences between the two occasions. From the limits of agreement, the activPAL™ records the same activity on two separate occasions within the ranges of −5.19 to 5.05, 95% of the time. CONCLUSIONS: The activPAL™ is valid and reliable in measuring physical activity in healthy participants within a laboratory-based setting. However, further studies are required to test this monitor in patients in free-living environments to confirm the clinical and research utility of this device. IMPLICATIONS: This study will be used to design studies to test this monitor in low back pain patients and thus may lead to better management of low back pain.

NA

Moorhead, A; Liddle, D; Hurley-Osing, D; Hager-Ross, C; Sundelin, G; Baxter, D; McDonough, S Physical activity monitoring in healthy adults World Congress of Physiotherapy 2007. NA.