Objective and self-reported occupational sitting and standing time: validity and responsiveness

van Nassau F, Chau J, Lakerveld J, Bauman A, van der Ploeg H

ISBNPA 2015: International Society of Behavioral Nutrition and Physical Activity, Edinburgh, UK 3 – 6 June 2015 (SO8.4.8, p 242)

Purpose: Valid instruments that detect changes in occupational sitting and standing time (e.g. responsiveness to change) are essential when evaluating effects of activity-permissive workplace interventions. Therefore, this study aimed: 1) to determine the criterion validity of the ActiGraph accelerometer, Occupational Sitting and Physical Activity Questionnaire (OSPAQ) and Workforce Sitting Questionnaire (WSQ) to assess occupational sitting and standing time compared to the activPAL, and 2) to determine the responsiveness of the activPAL, ActiGraph, OSPAQ and WSQ to changes in occupational sitting and standing time following the successful introduction of a sit-stand workstation. Methods: 42 participants took part in the Stand@Work intervention trial that used a randomized controlled crossover design with a waitlist control group and rolling recruitment. Six (T0) and two weeks before (T1) they were introduced to a sit-stand workstation and three weeks thereafter (T2), participants completed the OSPAQ and WSQ and wore an ActiGraph and activPAL activity monitor. The activPAL was used as the criterion validity measure. Results: The ActiGraph showed strong validity for occupational sedentary time at T0 and T1 (Spearman rho=0.79 and 0.69), but its validity dropped substantially after introduction of the sit-stand workstation (rho=0.10). Correlations of ActiGraph occupational light intensity activity and activPAL occupational standing time varied between 0.31-0.66. The occupational sitting validity correlation of the OSPAQ and WSQ varied from 0.35-0.41 and 0.25-0.30, respectively, and between 0.06-0.68 for the OSPAQ for occupational standing time. The intervention-induced changes in occupational sitting and standing time were well detected by the activPAL, OSPAQ and WSQ (sitting only), but not by the ActiGraph, which had the lowest responsiveness to change. Conclusion: Since the workplace is regarded as a suitable setting to interrupt prolonged sitting periods, future studies aimed at determining differences in occupational sitting and standing time should contemplate the activPAL-type inclinometers as a preferred objective measure. Simple questionnaires showed sufficient validity and can be used in addition to an objective measure or by itself when objective monitoring is not possible. The hip-worn ActiGraph was unable to distinguish between occupational sitting and standing time, when using uniaxial data and traditional cut-points for sedentary time and light intensity activity.

NA

van Nassau F, Chau J, Lakerveld J, Bauman A, van der Ploeg H Objective and self-reported occupational sitting and standing time: validity and responsiveness ISBNPA 2015: International Society of Behavioral Nutrition and Physical Activity, Edinburgh, UK 3 – 6 June 2015 (SO8.4.8, p 242) 2015. https://www.isbnpa.org/files/annual_meetings/2015/06/10/16/attachments/557869344fefe.pdf.