Pfister, TR; Wang, Q; Kopciuk, KA; Doyle-Baker, P; McLaren, L; Matthews, CE; Courneya, KS; Friedenreich, CM
3rd International Conference on Ambulatory Monitoring of Physical Activity and Movement
INTRODUCTION: A central aspect of physical activity (PA) and sedentary behavior (SB) research is the accurate assessment of PA in the context of disease outcomes. By objectively measuring PA and SB, some of the measurement errors inherent in self-reported measures may be minimized and more accurate estimates of the association between PA and SB and health can be achieved. PURPOSE: To evaluate the convergent validity of the ActiGraph® GT3X+ (AG) and ActivPAL3™ (AP) accelerometers in a free-living sample of postmenopausal women. METHODS: Participants are from the Breast Cancer and Exercise Trial in Alberta (BETA Trial), a randomized controlled exercise intervention trial comparing the effects of a moderate (150 min/wk) versus high volume exercise (300 min/wk) intervention on biological mechanisms hypothesized to mediate the association between PA and postmenopausal breast cancer risk. Participants wore both monitors concurrently during waking hours for seven-days at the 6 month (n=208) time point, and completed a monitor wear log. AG summary measures (hrs/d) were: SB-inclinometer, SB-100cpm, and using vector magnitude counts per minute (cpm) time in moderate (2691-6166 cpm), vigorous (6167+ cpm) and light (0-2690 cpm – SB-inclinometer) activity was calculated. Total AG activity time was the sum of light, moderate, and vigorous time. AP summary measures (hrs/d) were: SB (sit/lie), upright (standing/stepping), moderate (3-5.9 METs), vigorous (6+ METs), and light activity (upright-mod-vig). Bland-Altman plots were used to measure mean differences and limits of agreement between monitors for time in SB, light, moderate and vigorous PA. RESULTS: For the AG measures of SB, SB-inclinometer values were significantly (p=0.0001) greater than SB-100cpm values. Compared to SB from the AP, SB-inclinometer values were no different (0.13 [-4.98 to 5.23] hrs/d, p=0.19) and the SB-100cpm values were lower (0.39 [-2.76 to 3.54] hrs/d, (p=<0.0001). Paired t-tests show no significant differences between AG and AP for time in light (-0.07 [-5.15 to 5.00] hrs/d; p=0.45) and moderate activity (-0.01 [-1.00 to 0.98] hrs/d; p=0.52) , but time recorded in vigorous activity by the AG was greater than AP (0.14 [-0.33 to 0.62] hrs/d, (p=<0.0001) and total activity for the AG was less than upright time for the AP (-1.32 [-6.16 to 3.52] hrs/d; p=<0.0001). CONCLUSION: The differences in reported estimates of time spent in various activity intensities from these two devices were small. For the majority of activities, the level of agreement suggests that the devices cannot be used interchangeably and if the study objectives include assessments of both PA and SB both devices may be useful.Pfister, TR; Wang, Q; Kopciuk, KA; Doyle-Baker, P; McLaren, L; Matthews, CE; Courneya, KS; Friedenreich, CM A Comparison of Two Accelerometers For Measuring Physical Activity and Sedentary Behaviour 3rd International Conference on Ambulatory Monitoring of Physical Activity and Movement 2013. http://www.umass.edu/sphhs/sites/default/files/ICAMPAM_Slide_Poster_Composite_6.6.pdf.