Southard KJ, Bai Y, Welk G, Ellingson L
ACSM 30 May – 3 June 2017, Denver; Med Sci Sport Exer 2017 May; 49 (5S) : 763
The International Physical Activity Questionnaire (IPAQ) is a validated and widely used self-report physical activity (PA) measure, however findings about validity have been somewhat equivocal. Purpose: This study evaluated the agreement of the IPAQ measure with a novel and objective activity monitoring method known as Sojourns Including Posture (SIP). The SIP method is based on the same bout detection method as the more established Sojourn method but incorporates data from the ActivPAL to provide more robust information about transitions between Sedentary and Light activity. The aim was to investigate differences between self-reported moderate (MPA), vigorous (VPA), and sedentary (SED) minutes to SIP data, to inform whether participants were able to accurately self-report PA and SED time. Methods: A sample of 93 inactive adults (53% female; 42 9.1 mean age) participated in this study. Participants received a wearable device to track PA. Post-intervention, individuals wore accelerometers for 1 week, and self-reported PA and SED via the IPAQ. Minutes of MPA, VPA, and SED from each measure were compared using Pearson correlations, equivalence testing, and Bland-Altman plots, with the SIP method as the criterion. Results: The overall Pearson correlation between the measures was low to moderate (r = 0.37, P < .05). The mean MPA via IPAQ was 96.9 87.8 minutes per day compared to 57.3 24.4 minutes per day measured by SIP. Mean VPA from the IPAQ was 8.99 6.76 minutes, while the SIP method reported 14.44 9.51 minutes. The mean SED via the IPAQ was 456.6 156.93 minutes compared to 546.13 104.42 minutes measured by SIP. Equivalence testing demonstrated that the MPA, VPA, and SED methods were not equivalent at the 10% equivalence zone. A Bland Altman plot was constructed to visualize the MPA data using 95% limits of agreement that are between -121.1 and 200.4. More data points trended below the mean of 39.65, suggesting proportional bias that self-report overestimated activity. Conclusions: This study provides some support for the use of the IPAQ, but confirms the common observation in self-report instruments with participants tending to overestimate their participation in MPA and underestimate sedentary time. The use of measurement error modeling and calibration methods may be needed to address this error in future studies.Southard KJ, Bai Y, Welk G, Ellingson L Equivalence Of Self-report And Accelerometer Measures Following A Physical Activity Intervention. ACSM 30 May – 3 June 2017, Denver; Med Sci Sport Exer 2017 May; 49 (5S) : 763 2017. http://journals.lww.com/acsm-msse/Fulltext/2017/05001/Equivalence_Of_Self_report_And_Accelerometer.2226.aspx.