van der Linden M, Rowe P, Nutton R
Knee Arthroplasty: Engineering Functionality, The Royal College of Surgeons, London, UK 7 – 9 April 2005
Introduction A number of studies of the effects of knee arthroplasty have confirmed that the removal of pain leads to improved quality of life and greater general mobility eg [1]. However, in a recent study Myles et al [2] measured the functional range of movement of the knee before and after total knee arthroplasty (TKA) and compared this with 20 age-matched normal subjects. Post-TKA the knee excursion of the patients during 11 functional activities was only slightly improved compared to pre surgery levels and the patients exhibited an average of 26% less knee joint excursion compared to the normal subject group. The Zimmer NexGen Legacy Flex implant is designed to provide a maximum passive range of movement of the knee of 155 ?. Yamazaki et al [3] reported that the use of a Hy-Flex knee implant, another high-flexion implant, increased passive range of motion one year after surgery to 122?, but did not report knee excursion during functional activities or impact on quality of life or patient satisfaction. This study is aimed to answer the following questions: Does the use of the high flexion implant produce significantly better passive ranges of motion (non weight bearing) measured on a couch than those obtained with the standard implant? Does the use of the high flexion implant produce significantly better functional knee excursion values than those obtained with the standard implant? Is there a relationship between functional knee excursion values and (non weight bearing) knee ranges of motion? Is there a relationship between functional knee excursion values and other impairments such as pain or muscle strength? Is there a relationship between functional knee excursion values and quality of life or patient satisfaction? Methods subjects Eighty subjects with osteoarthritis undergoing a TKA will be recruited. Forty will be randomly assigned to either the high flexion or standard implant group. For comparison, 40 healthy age matched control subjects will also be recruited. Outcome measurements The primary outcome measurement is the knee motion during functional daily activities such as sitting down and getting up from a chair, getting in and out of a bath, walking on a slope and flat surface and stair ascent and descent. The patients are also asked to flex their knee as far as possible by placing one leg on a stool (weight bearing flexion). Other outcome measurements are maximum non-weight bearing knee flexion, knee extensor and flexor strength, the American Knee Score, WOMAC, SF36 and pain VAS. Apart from these standard outcomes, we also collect data on physical mobility over 24 hours using an activity monitoring device (ActivPAL) and questionnaires on pain belief and pain coping strategies using the Tampa scale for kinesiophobia [4], Coping Strategies Questionnaire [5] and Helplessness subscale of the Rheumatology Attitudes Index [6]. Results So far twelve patients and 26 control subjects have been tested. Table 1shows the subject physical examination characteristics and table 2 the knee motion during the activities in daily life. The total amount of time spent stepping as a percentage of the whole day and measured by the ActivPAL is also included in this table. Table 1 Mean and standard deviation of physical examination characteristics Patients Controls Affected Contra-lateral Age (yrs) 71 (6.9) 68 (6.2) BMI (kg/m2) 31.5(5.1)* 25.3(3.7) Walking speed (m/s) 0.91(0.17) 1.25(0.11) Knee flexion (non weight bearing) 102 (12)* 110 (12) 136 (6) Knee extensor strength (N/kg) 1.59(0.70)* 2.10(0.63) 3.27(1.18) Knee flexor strength (N/kg) 1.04(0.30)* 1.18(0.41) 1.67(0.50) * significant different between affected leg/patients and controls p<0.05 significant different between affected and contra-lateral leg p<0.05 Table 2 Mean and standard deviation of the functional parameters Patients Controls Affected Contra-lateral Knee flexion (weight bearing) 94(11)* 102(15) 135(12) In of bath 83(20)* 95(17) 124(27) Out of bath 90(18)* 94(19) 126(28) Stair ascent 72(15)* 78(12) 102(10) Stair descent 59(24)* 77(13) 97(7) Slope ascent 49(10)* 53(8) 65(6) Slope descent 51(14)* 55(8) 70(5) % time spent stepping 12.5(6.0)* 20.0(7.9) * significant different between affected leg/patients and controls p<0.001 significant different between affected and contra-lateral leg p<0.05 The correlation coefficients between the outcome measurements showed clinically important relationships (r>0.6) between the knee muscle strength and range of knee motion in stair ascent, slope ascent and descent, and getting in and out of a bath, the amount of time spent stepping , the physical function score of the SF36 and the Tampa and helplessness questionnaires. Weight bearing knee flexion correlated with the range of motion during sitting down and getting up from a chair, getting in and out of a bath, slope ascent and descent and the physical component of the SF36. On the contrary, non-weight bearing knee flexion only correlated with the time spent sitting as measured with the activPAL and weight bearing flexion, but with none of the functional activities. Discussion Preliminary results confirm the findings of Myles et al [2] that patients use less range of motion during daily activities. It was also shown that Physical Mobility is significantly reduced in patients waiting for a knee replacement surgery. Another important preliminary result is that physical examination parameters such as knee muscle strength and maximum weight bearing knee flexion correlate better with functional knee range of motion than the conventional non-weight bearing knee flexion measured on the plinth.van der Linden M, Rowe P, Nutton R Randomised Comparative Trial to Compare the Functional Outcome in the Standard Nexgen Legacy Knee Replacement to the Nexgen Legacy Flex Knee Replacement: Preliminary Results Knee Arthroplasty: Engineering Functionality, The Royal College of Surgeons, London, UK 7 – 9 April 2005 2005. NA.