Tag: Validation

  • Validating the Longitudinal Assessment of Sedentary Behavior in a Randomized Controlled Trial via a Deep-Learning Algorithm

    Morales, Jasmine; Zablocki, Rong W.; Hartman, Sheri J.; Kumar, Arun; Kumar, Animesh; Carlson, Jordan A.; Greenwood-Hickman, Mikael Anne; Hibbing, Paul R.; Staudenmayer, John; Di, Chongzhi; Zou, Jingjing; Nguyen, Steve; LaCroix, Andrea Z.; Dillon, Lindsay; Ryu, Howon; Shao, Lucy; Shi, Weiwei; Tuz-Zahra, Fatima; Natarajan, Loki

    Journal for the Measurement of Physical Behaviour

    Background: Sedentary behavior (SB) is a risk factor for cardiometabolic disease. Existing cut points of hip-worn accelerometers to quantify SB underestimate sedentary bout durations by ignoring posture. To address this, we previously developed Convolutional Neural Network Hip Accelerometer Posture (CHAP), a deep-learning algorithm that predicts sitting and breaks from sitting. In this study, we applied CHAP to a randomized controlled trial to externally validate its accuracy for classifying sitting versus nonsitting and estimating intervention-related changes in SB.

    Methods: CHAP was applied to 30-Hz triaxial hip-worn ActiGraph-GT3X+ (AG) accelerometer data from free-living postmenopausal women who are overweight (≥55 years) in the Rise for Health RCT (n = 406). CHAP-predicted SB accuracy (e.g., sensitivity) and daily pattern metrics (e.g., total sedentary time) were compared with a ground-truth device activPAL (AP) and standard cut-point method (AG100) at two timepoints for intervention arms—Healthy Living (control), Reduce Sitting, and Increase Transitions.

    Results: CHAP’s SB accuracy metrics were above 84.8%. Mean (standard error, p values) intervention effect estimates (mean change, intervention minus controls) from generalized estimating equation models for (a) total sedentary time were AP 65.1 min/day (16.2, p < .001), CHAP 38.2 min/day (15.4, p = .013), and AG100 0.28 min/day (13.9, p = .98; Reduce Sitting); (b) breaks from SB were AP 22/day (4.3, p < .001), CHAP 4/day (1.5, p = .003), and AG100 <1/day (2.1, p = .860; Increase Transitions).

    Conclusions: This study validated CHAP on an independent cohort. CHAP exhibited high prediction accuracy, and although less sensitive than AP, CHAP detected changes in SB more effectively than AG100. Thus, CHAP could make a strong contribution to SB intervention research.

    10.1123/jmpb.2025-0086

    Morales, Jasmine; Zablocki, Rong W.; Hartman, Sheri J.; Kumar, Arun; Kumar, Animesh; Carlson, Jordan A.; Greenwood-Hickman, Mikael Anne; Hibbing, Paul R.; Staudenmayer, John; Di, Chongzhi; Zou, Jingjing; Nguyen, Steve; LaCroix, Andrea Z.; Dillon, Lindsay; Ryu, Howon; Shao, Lucy; Shi, Weiwei; Tuz-Zahra, Fatima; Natarajan, Loki Validating the Longitudinal Assessment of Sedentary Behavior in a Randomized Controlled Trial via a Deep-Learning Algorithm Journal for the Measurement of Physical Behaviour 2026. https://journals.humankinetics.com/view/journals/jmpb/9/1/article-jmpb.2025-0086.xml.

  • Robust Assessment of Free-Living Physical Behaviors and Activity Intensity Using Dual-Wearable Multitask Learning: Development and Evaluation Study From the Multicenter WEALTH Project

    Sigcha, Luis; Swenne, Annika; Hayes, Grainne; Kuhnova, Jitka; Cimler, Richard; Elavsky, Steriani; Vetrovsky, Tomas; Kamedjie, Léopold Fezeu; Bouchan, Jérôme; Oppert, Jean-Michel; Harrington, Janas; Cardon, Greet; Hebestreit, Antje; Donnelly, Alan; Ven, Pepijn Van de; Buck, Christoph; Consortium, Wealth

    JMIR mHealth and uHealth

    Background: Accurate assessment of physical behaviors (PBs) and activity intensity is essential for public health research and digital health monitoring. Wearable accelerometers combined with machine learning (ML) or deep learning (DL) enable objective behavior assessment, but most existing models are trained on laboratory data, limiting generalizability to free-living conditions.

    Objective: This study aimed to develop and evaluate multitask ML and DL models for PB classification across 7 categories (sitting, standing, walking, running, sports, cycling, and lying) and activity intensity categories (AIC) across 3 levels (sedentary, light, and moderate-to-vigorous physical activity) using thigh-worn (activPAL) and waist-worn (ActiGraph) wearable accelerometers. A second objective was to compare model-derived estimates of daily time spent in PB and AIC across single- and dual-sensor (activPAL + ActiGraph) configurations, and to evaluate agreement between the best-performing model and corresponding estimates obtained from the proprietary activPAL classification of real-world everyday activities (CREA) algorithm using free-living data collected over a 9-day monitoring period.

    Methods: Data were obtained from 590 adults in the multicenter WEALTH study (627 recruited) and included up to 9 days of concurrent activPAL and ActiGraph free-living recordings. Sparse accelerometer-labeled data were obtained using ecological momentary assessment and refined by retaining instances with ≥75% agreement with the CREA algorithm. Resulting labeled data of 583 participants were used to develop ML models for single-sensor (activPAL or ActiGraph) and combined (dual-sensor) configurations. A random forest (RF) model using engineered features and a multihead convolutional neural network (MH-CNN) were trained within a multitask learning framework to jointly predict PB (task 1) and AIC (task 2) using a subject-independent hold-out split. The test subset (n=87) was used to estimate daily time spent in PB and AIC over 9 days, which were compared with CREA-derived estimates using Pearson coefficients and intraclass correlation coefficients (ICCs).

    Results: The dual-sensor configuration consistently outperformed single-sensor models. For PB classification, the MH-CNN achieved the highest performance (-score=0.750). For AIC, the RF model performed best (-score=0.741). Dual-sensor free-living estimates showed epidemiologically plausible distributions across the 24-hour period, including sitting 37% (538/1440 min), lying 34% (496/1440 min), walking 9% (131/1440 min), and moderate-to-vigorous physical activity (MVPA) 2% (31/1440 min). Agreement with CREA was strongest for standing, walking, and cycling (≥0.86; ICC ≥0.72), while lying showed modest reliability (ICC=0.48). For AIC, agreement was highest for light physical activity (LPA) and MVPA (ICC 0.72‐0.75).

    Conclusions: Multitask models combining thigh- and waist-worn accelerometers provide consistent estimates of PB and AIC under free-living conditions. The dual-sensor approach yielded more stable and epidemiologically coherent estimates than single-sensor methods, supporting its potential for large-scale population monitoring and mobile health apps.

    International Registered Report Identifier (IRRID): RR2-10.2196/preprints.70186

    10.2196/94302

    Sigcha, Luis; Swenne, Annika; Hayes, Grainne; Kuhnova, Jitka; Cimler, Richard; Elavsky, Steriani; Vetrovsky, Tomas; Kamedjie, Léopold Fezeu; Bouchan, Jérôme; Oppert, Jean-Michel; Harrington, Janas; Cardon, Greet; Hebestreit, Antje; Donnelly, Alan; Ven, Pepijn Van de; Buck, Christoph; Consortium, Wealth Robust Assessment of Free-Living Physical Behaviors and Activity Intensity Using Dual-Wearable Multitask Learning: Development and Evaluation Study From the Multicenter WEALTH Project JMIR mHealth and uHealth 2026. https://mhealth.jmir.org/2026/1/e94302.

  • Influence of Minimum-Duration Processing Settings on activPAL-Derived Sit-to-Stand Transitions and Sedentary Behavior Metrics in Free-Living Chronic Stroke Survivors: An Exploratory Pilot Study

    August 2026

    Shibuya, Mitsutaka; Harada, Kazuhiro; Uguisu, Haruo; Hirashima, Kenichi

    Cureus

    Background and objective: The activPAL monitor (PAL Technologies, Glasgow, UK) is widely used to assess posture, stepping activity, sit-to-stand transitions, and sedentary behavior. However, estimates derived from the same activPAL recording may vary according to the minimum-duration settings applied during data processing. Such processing-related differences may affect the interpretation of daily sit-to-stand frequency and sedentary interruption patterns. This exploratory pilot study examined whether processing identical free-living activPAL recordings using 2-second and 10-second minimum-duration settings produced different sit-tostand, stepping, standing, and sedentary behavior outputs in chronic stroke survivors. Methods: This study was an exploratory secondary analysis of free-living activPAL data from 12 chronic stroke survivors who were able to perform sit-to-stand transfers independently. Each raw activPAL4 recording was processed twice using PALbatch, the manufacturer-provided batch-processing software for activPAL data. In the 2-second condition, both the minimum upright period and the minimum non-upright period were set to 2 seconds. In the 10-second condition, both parameters were set to 10 seconds. The 10-second condition represented the default PALbatch setting, and all other processing settings were held constant between conditions. The primary outcome was the daily number of sit-to-stand transitions. Secondary outcomes were step count, stepping time, standing time, total sedentary time, and sedentary bout metrics. Participant-level averages across valid recording days were compared using the paired Wilcoxon signed-rank test. Secondary analyses were exploratory and were not adjusted for multiple comparisons. Results: Daily sit-to-stand counts were higher in the 2-second condition than in the 10-second condition (52.8 ± 32.1 vs. 46.4 ± 28.2 transitions/day; mean paired difference, 6.4 transitions/day; p = 0.004). The number of sedentary bouts shorter than 30 minutes was also higher in the 2-second condition (p = 0.004). Differences in step count, stepping time, and standing time were small. Total sedentary time differed by 2.4 min/day (p = 0.035), whereas sedentary bouts lasting 30 minutes or longer showed little difference between conditions. Conclusions: In this available-case sample, minimum-duration processing settings were primarily associated with differences in daily sit-to-stand counts and the number of short sedentary bouts. Differences in steppingrelated outcomes, total sedentary time, and prolonged sedentary bout metrics were small. Because no direct observation or video-based criterion measure was available, the findings do not indicate which setting was more accurate. Instead, they show that processing settings can influence the operational definition and interpretation of activPAL-derived sit-to-stand and sedentary interruption outcomes. Researchers should report these settings explicitly and apply consistent processing rules when comparing groups, measurement occasions, or studies.

    10.7759/cureus.113847

    Shibuya, Mitsutaka; Harada, Kazuhiro; Uguisu, Haruo; Hirashima, Kenichi Influence of Minimum-Duration Processing Settings on activPAL-Derived Sit-to-Stand Transitions and Sedentary Behavior Metrics in Free-Living Chronic Stroke Survivors: An Exploratory Pilot Study Cureus 2026. https://www.cureus.com/articles/502041-influence-of-minimum-duration-processing-settings-on-activpal-derived-sit-to-stand-transitions-and-sedentary-behavior-metrics-in-free-living-chronic-stroke-survivors-an-exploratory-pilot-study.

  • Validation of within-person associations with coverage and momentary EMA self-reports using an objective standard (physical activity)

    July 2026

    Stone, Arthur A.; Toledo, Meynard; Schneider, Stefan; Smyth, Joshua M.; Junghaenel, Doerte U.; Goldstein, Sarah; Pomeroy, Olivia

    Scientific Reports

    Ecological momentary assessment (EMA) is a useful tool for assessing peoples’ experiences, behaviors, and environments in everyday life. EMA is considered a standard for self-reporting, because its short reporting periods and multiple assessments in everyday life offers reduced recall bias and increased ecological validity. In this study we tested how well within-person EMA measurements of levels of physical activity (prompt-level data) match objective reports of activity from accelerometry. We looked at two kinds of validity: duration of EMA recall (5 m; 120 m) and type of physical activity response scale (verbal response scales [VRS]; numerical duration scales). Concurrent criterion validity was tested by examining level differences and with correlations of EMA with accelerometry. Construct validity was assessed by examining whether the correlations between EMA and non-physical activity variables aligned with correlations between accelerometry and those same variables. Participants (N = 315) wore a thigh accelerometer and completed EMA five times per day for 7-days. We observed that EMA estimates of activity levels were very different compared with accelerometry levels, especially for active behavior, where EMA yielded much higher levels of active behavior than accelerometry (the first type of concurrent criterion validity). We found moderate within-person correlations between EMA and accelerometry (second type of concurrent criterion validity). However, some study factors moderated the concordance: coverage EMA had slightly stronger associations than near-momentary EMA and sedentary behavior was more accurately reported than high physical activity levels. Construct validity analyses showed that EMA self-reports could be used in place of accelerometry data. With the caveat that physical activity was greatly overestimated by EMA, findings largely support the utility of EMA for analyzing within-person associations with other coverage and near-momentary variables, although they suggest some forms of EMA may be somewhat less optimal.

    10.1038/s41598-026-61581-9

    Stone, Arthur A.; Toledo, Meynard; Schneider, Stefan; Smyth, Joshua M.; Junghaenel, Doerte U.; Goldstein, Sarah; Pomeroy, Olivia Validation of within-person associations with coverage and momentary EMA self-reports using an objective standard (physical activity) Scientific Reports 2026. https://www.nature.com/articles/s41598-026-61581-9.

  • How Many Days Do We Need? Defining Reliable ActivPAL Monitoring Protocols for Distinct Movement Behaviors in Office Workers

    Espin, Ander; Júdice, Pedro B.

    Scandinavian Journal of Medicine & Science in Sports

    Although device-measured data provide more reliable estimates of movement behaviors than self-report questionnaires, device-monitoring protocols are often demanding in terms of time, logistics, and costs. Identifying the minimum monitoring duration to obtain reliable data is therefore essential, yet evidence for ActivPAL devices remains limited. The objective of this study was to determine the minimum number of days required to reliably estimate movement behaviors using ActivPAL. As a secondary aim, we examined how different combinations of weekdays and weekend days influence reliability. A total of 106 monitoring periods of six consecutive days from adult office workers were analyzed, corresponding to 636 monitored days or 15 264 h collected. Taking the 6-day period as reference, the reliability of shorter monitoring durations (1–5 days) was assessed. Relative and absolute reliability were confirmed when an intraclass correlation coefficient ≥ 0.85 and a coefficient of variation < 10% were achieved, respectively. Movement behaviors assessed included stepping time, standing time, sedentary time, sitting time, primary lying time, step count, and sit-to-stand transitions. Based on these criteria, two monitoring days were sufficient to achieve both relative and absolute reliability for sit-to-stand transitions, while 3 days were sufficient for sedentary time, sitting time, and primary lying time. Four days were required to achieve comparable reliability for stepping time, standing time, and step count. Overall, monitoring periods that combined weekdays and weekend days tended to demonstrate higher reliability than those including only weekdays or weekend days. These findings may guide optimization of ActivPAL monitoring protocols, reducing participant and researcher burden while maintaining reliable movement behavior estimates.

    10.1111/sms.70344

    Espin, Ander; Júdice, Pedro B. How Many Days Do We Need? Defining Reliable ActivPAL Monitoring Protocols for Distinct Movement Behaviors in Office Workers Scandinavian Journal of Medicine & Science in Sports 2026. https://onlinelibrary.wiley.com/doi/abs/10.1111/sms.70344.

  • Validation of the ACT24 Physical Activity Instrument in Women Undergoing Chemotherapy

    Bertram, Jessica; Goh, Hui-Ting; Trudelle-Jackson, Elaine

    Rehabilitation Oncology

    Background: While physical activity during chemotherapy is recognized as a vital component of overall health and well-being, there is a lack of ideal measures that can accurately and efficiently measure physical activity. The purposes of this study were to (1) validate the Activities Completed over Time in 24 Hours (ACT24) instrument and (2) evaluate participant use and acceptability of the ACT24 for women undergoing active chemotherapy for the treatment of breast cancer.

    Methods: Twenty-two women receiving chemotherapy wore an activPAL device for 7 days and completed 3 ACT24 previous day recalls. Criterion validity was assessed using correlation coefficients, paired t tests, and Bland–Altman plots from data collected on matched days for the ACT24 and activPAL. Outcomes of interest included MET-hrs/day, active time, and sedentary time. Acceptability was assessed using the System Usability Scale and Experience survey.

    Results: The correlations between the ACT24 and activPAL were significant for MET-hrs/day (ρ = 0.80, P <.001), active time (ρ = 0.70, P <.001), and sedentary time (ρ = 0.67, P <.001); and there were no significant differences in measures obtained with the ACT24 and activPAL for all outcomes (P ranged from 0.222 to 0.706). For usability, the ACT24 exceeded the mean cutoff score of usability on the System Usability Scale, indicating acceptable usability of the measure.

    Conclusion: The ACT24 is a valid and acceptable tool to quantify physical activity levels in this population. The instrument is a standardized physical activity measure that measures all activity, regardless of type or intensity, which may be ideal for women undergoing chemotherapy.

    10.1097/01.REO.0000000000000413

    Bertram, Jessica; Goh, Hui-Ting; Trudelle-Jackson, Elaine Validation of the ACT24 Physical Activity Instrument in Women Undergoing Chemotherapy Rehabilitation Oncology 2026. https://www.ovid.com/jnls/rehabonc/fulltext/10.1097/01.reo.0000000000000413~validation-of-the-act24-physical-activity-instrument-in.

  • Comparison of activPAL and ActiGraph measured moderate to vigorous physical activity in people with COPD

    Son, Jung Yoen; Webster, Katelyn E; Marriot, Deanna; Tucker, She’Lon; Larson, Janet L

    Physiological Measurement

    Objective: ActiGraph accelerometers are commonly used to assess moderate-to-vigorous physical activity (MVPA), but there are concerns about missing data due to compliance issues with hip-worn devices. ActivPAL devices are worn 24 hours/day on the anterior thigh, minimizing missing data, but activPAL software does not directly estimate MVPA. This study aimed to evaluate the agreement between MVPA derived from activPAL (using five methods) and ActiGraph data (using two methods) among individuals with chronic obstructive pulmonary disease (COPD).

    Approach: In this secondary analysis, 148 inactive adults aged ≥50 years with COPD wore an activPAL3 on the thigh and an ActiGraph GT9X on the hip concurrently for 7 days. MVPA was estimated from activPAL using five methods: 1) metabolic equivalents, 2) ≥75 steps/min, 3) ≥100 steps/min, 4) vector magnitude (VM) counts, and 5) vertical-axis counts, and from ActiGraph using Freedson VM3 (2011) and Evenson (2023) VM cut-points, 60s epochs, and normal filters. We assessed agreement between activPAL and ActiGraph MVPA using concordance correlation coefficients (CCCs), two one-sided t-tests (TOST), and Bland-Altman plots.

    Main results: Compared with ActiGraph MVPA using Freedson VM3, CCCs ranged from 0.51 to 0.53 across activPAL methods, except for ≥100 steps/min (CCC=0.42); four of five activPAL methods were equivalent at a ±8 min/day equivalence margin. Compared with ActiGraph MVPA using Evenson, CCCs ranged from 0.20 to 0.25 across activPAL methods, and no activPAL method was equivalent.

    Significance: ActivPAL MVPA showed moderate group-level agreement and equivalence when compared to ActiGraph MVPA using Freedson VM3. Findings suggest activPAL may estimate group-level MVPA in this population, though further research is needed to validate this approach for individual-level MVPA.

    10.1088/1361-6579/ae87f1

    Son, Jung Yoen; Webster, Katelyn E; Marriot, Deanna; Tucker, She’Lon; Larson, Janet L Comparison of activPAL and ActiGraph measured moderate to vigorous physical activity in people with COPD Physiological Measurement 2026. http://iopscience.iop.org/article/10.1088/1361-6579/ae87f1.

  • Evaluating Open-Source Wrist-Worn Accelerometer Models for Sedentary Time Detection Against Thigh-Worn Accelerometer Data

    Acquah, Aidan; Broomberg, Katya; Dunstan, David W.; Healy, Genevieve N.; Davies, Melanie J.; Edwardson, Charlotte L.; Doherty, Aiden; Maylor, Benjamin D.

    Preprint

    Objective: Wrist-worn accelerometers are common in large-scale epidemiological studies, but their ability to measure sedentary behaviour in free-living environments is unknown. We therefore aimed to evaluate the accuracy of openly-available methods to infer sedentary time from wrist-worn accelerometers.

    Methods: We analysed data from 662 working-age adults in the SMART Work & Life study (20-70 years; mean age 45 years; 72% female) who concurrently wore wrist- and thigh-worn accelerometers for up to eight free-living days. Reference measurements of sedentary time were derived from the thigh accelerometer data using proprietary algorithms. Wrist accelerometer data were processed using widely used, publicly available activity recognition models. Performance was evaluated at 30-second epochs to generate per-participant metrics, alongside comparisons of mean daily sedentary time, mean daily number of prolonged sedentary bouts (≥ 30 minutes) and proportion of sedentary time in prolonged bouts. Model performance was examined across subgroups defined by age, sex, body mass index, season, recruitment centre, and in sensitivity analyses restricted to daytime hours (08:00–22:00).

    Results: The best performing machine learning model (Actinet) accurately classified sedentary time from wrist-worn accelerometer data with a mean per-participant accuracy of 0.87 and F1 score of 0.85. Cut point-based approaches demonstrated lower accuracy of 0.80 (F1 score of 0.79). The ActiNet machine learning model showed strong agreement in daily sedentary time, daily number of prolonged sedentary bouts and proportion of sedentary time in prolonged bouts, all within 10% of the free-living thigh reference. Findings were consistent across subgroups and in analyses restricted to daytime hours.

    Conclusion: Wrist-worn accelerometers can provide accurate measurements of sedentary behaviour in free-living settings, when assessed using current machine learning models, particularly ActiNet. This work provides confidence in future epidemiological research to examine sedentary behaviour patterns from wrist-worn accelerometers and their associations with health outcomes.

    10.64898/2026.06.30.26356834

    Acquah, Aidan; Broomberg, Katya; Dunstan, David W.; Healy, Genevieve N.; Davies, Melanie J.; Edwardson, Charlotte L.; Doherty, Aiden; Maylor, Benjamin D. Evaluating Open-Source Wrist-Worn Accelerometer Models for Sedentary Time Detection Against Thigh-Worn Accelerometer Data NA 2026. https://www.medrxiv.org/content/10.64898/2026.06.30.26356834v1.

  • Validity of the PROMIS ability to participate in social roles and activities measure in older adult health assessment

    Houck, Jeff; Johnson, Christen; Raudsepp, Theresa; Zablotny, Cindy

    Advances in Patient-Reported Outcomes

    Objective: The International Classification of Function is often used in older adult clinical assessments. Well recognized is the high value, and difficulty, of assessing participation in social roles. The PROMIS Ability to Participate in Social Roles (APSR) measure may augment assessments enhancing our understanding of older adults’ participation in social roles. The purpose of this study was to examine whether the APSR diverges with other clinical measures suggesting it is measuring a separate construct adding new information to the clinical assessment.

    Methods: A sample of convenience of older adults (n = 89) was recruited and administered clinical assessments that include physical capacity and performance tests, activity data (e.g. wearable accelerometer), and other PROMIS physical health (physical function (PF), pain interference (PI) and fatigue) and mental health (General Self-Efficacy and Depression) measures. Analysis focused on 1) Whether these measures were correlated with the APSR measure; And, 2) whether APSR measure discriminated older adults at risk for falls, decreased mobility, hospitalization and mortality. Spearman Rho values from < 0.7 were classified as divergent. A combination of t-tests and receiver operator curve analysis was used to assess the ability of the APSR to discriminate groups.

    Results: The results showed 1) Significant weak correlations, suggesting divergence (<0.7), between the APSR measure and physical capacity and performance tests; 2) No correlations of activity data variables with the APSR measure: And 3) weak and moderate correlations of PROMIS physical health measures with the APSR measure were considered divergent (<0.7). The APSR measure showed medium to large effect sizes for discriminating older adults at risk for falls, decreased mobility, hospitalization mortality.

    Conclusion: The APSR measure was sufficiently uncorrelated with clinical tests and other PROMIS measures to offer unique information regarding an older adult’s participation in social roles.

    Impact statement: This data encourages clinical measurement of social participation in older adults. The self-reported PROMIS APSR measure was supported as a potential measure of perceived social participation that augments current clinical assessments.

    10.1016/j.apro.2026.100331

    Houck, Jeff; Johnson, Christen; Raudsepp, Theresa; Zablotny, Cindy Validity of the PROMIS ability to participate in social roles and activities measure in older adult health assessment Advances in Patient-Reported Outcomes 2026. https://www.sciencedirect.com/science/article/pii/S3050696426000169.

  • Ubiquitous Non-Wearable Sensor for Human Sedentary Behavior Monitoring and Characterization

    Ye, Anjia; Maiti, Ananda; Schmidt, Matthew; Pedersen, Scott J.

    Sensors

    Occupational sedentary behavior presents a public health risk, yet current interventions often rely on subjective self-reports or context-blind prompts. This study validates a privacy-preserving, edge-computing time-of-flight (ToF) sensor that detects postural states and quantifies therapeutic exercise gestures in real time. The dual-sensor architecture distinguishes between sitting, standing, and absence, while capturing rapid sit-to-stand repetitions suitable for active-break interventions. In this paper, a laboratory study (N = 7) evaluated the system against ground truth comprising activPAL3 accelerometry and video analysis. Across 378 postural events, the sensor achieved high temporal fidelity (mean absolute error < 1.6 s) and 100% sensitivity in counting exercise repetitions. The system differentiated workstation occupancy from physical absence. These findings demonstrate that ToF sensing matches the accuracy of video analysis without privacy concerns while offering the contextual awareness required for just-in-time, adaptive workplace interventions.

    10.3390/s26082468

    Ye, Anjia; Maiti, Ananda; Schmidt, Matthew; Pedersen, Scott J. Ubiquitous Non-Wearable Sensor for Human Sedentary Behavior Monitoring and Characterization Sensors 2026. https://www.mdpi.com/1424-8220/26/8/2468.

  • Criterion validity of the International Physical Activity Questionnaire Short Form against activPAL in overweight and obese adults: a cross-sectional study

    Yang, Jundi; Chen, Wei; Li, Wanyang; Fong, Daniel Yee Tak; Ho, Mandy

    BMJ Open

    Objectives: To evaluate the criterion validity and test–retest reliability of the Chinese version International Physical Activity Questionnaire-Short Form (cIPAQ-SF) for assessing sedentary behaviour and physical activity (PA) in overweight and obese Chinese adults, using activPAL as the reference.

    Methods: A cross-sectional study was conducted at a Clinical Nutrition Clinic in China. Participants completed the cIPAQ-SF before and after wearing an activPAL for 7 consecutive days. Criterion validity was assessed using Pearson’s/Spearman’s correlation coefficients and Bland-Altman plots for sitting time (hours/day), moderate, vigorous and moderate-to-vigorous PA (MVPA) (min/week). Sensitivity and specificity evaluated the IPAQ-SF’s accuracy in identifying those not engaging in any PA and those not meeting the PA recommendation (MVPA ≥150 min/week). Test–retest reliability was assessed using intraclass correlation (ICC).

    Results: Among 80 participants (age 33.9±7.3 years; body mass index 29.1±4.5 kg/m²), the IPAQ-SF demonstrated moderate criterion validity for sitting time (r=0.577 on weekdays, r=0.444 on weekends) and MVPA (ρ=0.451) compared with activPAL. It underestimated sitting time by 3.5 hours/day on weekdays and 2.9 hours/day on weekends. The cIPAQ-SF showed moderate-to-high sensitivity for correctly identifying individuals who were not engaging in any PA (53.6%–85.7%) or not meeting PA recommendations (93.8%), but its specificity was low to moderate (47.8%–73.7%) for PA engagement and meeting guidelines (55.2%). Test–retest reliability was moderate for sitting time (ICC=0.549–0.614) and poor to moderate for PA levels (ICC=0.453–0.592).

    Conclusion: The IPAQ-SF demonstrates moderate validity and reliability in assessing sedentary behaviour and insufficient PA among overweight and obese Chinese adults. It can be used to identify physically inactive individuals for targeted interventions and monitor changes in sedentary behaviour.

    10.1136/bmjopen-2025-101626

    Yang, Jundi; Chen, Wei; Li, Wanyang; Fong, Daniel Yee Tak; Ho, Mandy Criterion validity of the International Physical Activity Questionnaire Short Form against activPAL in overweight and obese adults: a cross-sectional study BMJ Open 2026. https://bmjopen.bmj.com/content/16/2/e101626.abstract.

  • Three Body-Worn Accelerometers in the French NutriNet-Santé Cohort: Feasibility and Acceptability Study

    Soumaré, Abdouramane; Fezeu, Léopold K.; Bouchan, Jérôme; Delestre, Fabienne; Bellicha, Alice; Cardon, Greet; Donnelly, Alan; Hebestreit, Antje; Touvier, Mathilde; Oppert, Jean-Michel; Vanhelst, Jérémy

    JMIR Formative Research

    Background: Accurate assessment of physical activity (PA) in large population-based cohorts remains a major methodological challenge. Self-reported questionnaires, although commonly used due to low cost and simplicity, are prone to recall and social desirability biases, causing misclassification and weakened associations with health outcomes. Body-worn accelerometers provide more objective and reliable measurements, but their acceptability and feasibility in large-scale epidemiological studies must be carefully evaluated to ensure compliance, data quality, and scalability.

    Objective: The primary objective was to assess the acceptability of using 3 body-worn accelerometer devices (Fitbit, ActivPAL, and ActiGraph) among healthy middle-aged adults participating in the NutriNet-Santé cohort. The secondary objective was to assess the feasibility of these devices in terms of wear-time compliance under free-living conditions.

    Methods: This is an ancillary study of the European WEALTH (WEarable sensor Assessment of physicaL and eaTing beHaviors) project that was conducted between 2023 and 2024 in a subsample of participants of the NutriNet-Santé surveillance in France. This sample included 126 healthy participants (62 men), with a mean age of 46.3 (SD 11.3) years. Participants wore simultaneously 3 body-worn accelerometer devices (Fitbit [wrist], ActivPAL [thigh], and ActiGraph [waist]) for 7 consecutive days. After the wear period, participants completed a specific 22-item web-based questionnaire, regarding their acceptability of using each device. This questionnaire was based on the Technology Acceptance Model, which identifies perceived usefulness and ease of use as key determinants of technology acceptance. Items were rated on a 5-point Likert scale (1=strongly disagree to 5=strongly agree). Feasibility was assessed based on the accelerometer wear time data reported in a log diary by participants. A valid day was defined as ≥600 minutes per day of wear time, and a valid week as at least 4 of such days. Acceptability scores were compared between devices using ANOVA, and feasibility outcomes were compared using Kruskal-Wallis tests.

    Results: The acceptability assessment based on the questionnaire revealed significant differences among the 3 devices (P<.001). The Fitbit achieved the highest acceptability score (mean 80.5/100, SD 8.13) across most criteria such as comfort, ease of use, and social acceptability, while the ActiGraph received the lowest score (mean 71.7, SD 8.68), mainly due to challenges with stability and interference during PA. In terms of feasibility, the 3 accelerometers demonstrated high compliance, with the ActivPAL recording the highest daily wear time, followed by the Fitbit and the ActiGraph (P<.001).

    Conclusions: Results from our study showed that the Fitbit watch appears as the most accepted device for measuring PA in free-living conditions in the NutriNet-Santé study. The large-scale use of such a device must now be evaluated in terms of logistics, cost, and data privacy.

    10.2196/76167

    Soumaré, Abdouramane; Fezeu, Léopold K.; Bouchan, Jérôme; Delestre, Fabienne; Bellicha, Alice; Cardon, Greet; Donnelly, Alan; Hebestreit, Antje; Touvier, Mathilde; Oppert, Jean-Michel; Vanhelst, Jérémy Three Body-Worn Accelerometers in the French NutriNet-Santé Cohort: Feasibility and Acceptability Study JMIR Formative Research 2025. https://formative.jmir.org/2025/1/e76167.

  • A scalable step count-based predictor of biological age: development and validation of MoveIt! Age in community-dwelling adults and geriatric rehabilitation inpatients

    Lu, Jessica K.; Wang, Weilan; Guan, Lihuan; van der Velde, Jeroen; Hoeks, Joris; Schrauwen, Patrick; Salomons, Gajja S.; Houtkooper, Riekelt H.; Maier, Andrea B.; Janssens, Georges E.

    GeroScience

    Measuring biological age typically requires invasive and costly procedures. To address this, the MoveIt! Age Score was developed: a simple, scalable, and interpretable aging clock that predicts biological age using only wearable-derived steps data. MoveIt! Age was trained on steps data from the United States National Health and Nutrition Examination Survey (NHANES), using chronological age, maximum step count, and step count variability to predict PhenoAge, a blood biochemistry biological age score. MoveIt! Age performance was evaluated in two independent cohorts: Mitochondria and Muscle Health in Elderly (MitoHealth; N = 55; healthy young adults or older adults from the Netherlands) and Restoring Health of Acutely Unwell Adults (RESORT; N = 145; geriatric rehabilitation inpatients from Australia). In RESORT, MoveIt! Age was assessed and compared to SenoClock-BloodAge and PhenoAge (hematological aging clocks). Delta age was the predicted biological age minus chronological age. In the NHANES testing dataset, MoveIt! Age demonstrated high predictive accuracy of chronological age (r = 0.97, RMSE = 5.4 years) and was more significantly associated with mortality than PhenoAge. In MitoHealth, delta MoveIt! Age showed differences between young adults and older adults who were normal, healthy, or health-impaired, with MoveIt! Age more significantly associated with muscle NAD+ levels (r = −0.37, p = 0.023) than chronological age (p = 0.416). Delta MoveIt! Age associated more strongly than other clocks with physical function outcomes, including frailty, handgrip strength, and functional performance. These findings support MoveIt! Age as a practical tool to gain insights into biological age in both clinical and community settings.

    10.1007/s11357-025-01999-7

    Lu, Jessica K.; Wang, Weilan; Guan, Lihuan; van der Velde, Jeroen; Hoeks, Joris; Schrauwen, Patrick; Salomons, Gajja S.; Houtkooper, Riekelt H.; Maier, Andrea B.; Janssens, Georges E. A scalable step count-based predictor of biological age: development and validation of MoveIt! Age in community-dwelling adults and geriatric rehabilitation inpatients GeroScience 2025. https://doi.org/10.1007/s11357-025-01999-7.

  • Feasibility of 24-hour physical behavior monitoring with thigh-worn accelerometers after childhood cancer – the Swiss Childhood Cancer Survivor Study (SCCSS) – Activity

    Nigg, C.; Mohr, D.; Schindera, C.; Brack, E.; Kuehni, C. E.

    Pre-print

    Background: A healthy lifestyle, including sufficient physical activity, limited sedentary behavior, and adequate sleep (24-hour physical behaviors) can mitigate late effect risks for childhood cancer survivors (CCS). Most research on 24-hour physical behaviors has been questionnaire-based, while device-based assessment is lacking. Here, we assess the feasibility of 24-hour physical behavior monitoring using thigh-worn accelerometers in an age-diverse CCS population.

    Methods: SCCSS-Activity is nested in the Swiss Childhood Cancer Survivor Study (SCCSS), a nation-wide questionnaire-based cohort study. As part of the 2024/2025 mailing, we asked participants if they are willing to participate in an accelerometer-based sub-study. Participants wore an activPAL4® accelerometer continuously for eight days. We investigated feasibility using the following indicators: recruitment rate, acceptability and suitability of contact procedures and measurement scheduling, accelerometer return and adherence, summary reports, and overall impression. We analyzed quantitative data descriptively and conducted semi-structured interviews with nine participants.

    Results: Of 367 CCS returning the baseline questionnaire (median: 14 years [IQR: 10-21]; 50% female), 157 (43%) expressed interest in the accelerometer study, 100 were enrolled as of June 2025, and 90 wore and returned the accelerometer, with all except two containing valid data. Participants wore the device for a median of seven days (IQR 7–8). Interview results indicated high acceptability and minimal burden.

    Conclusion: Twenty-four-hour physical behavior assessment using thigh-worn accelerometers is feasible and well accepted among pediatric, adolescent, and adult CCS. This holds promise for future research to better understand and intervene on physical behaviors and to understand their compositional impact on CCS’ health.

    Highlights: Thigh-worn accelerometry is feasible to assess 24-hour physical behaviors in survivors43% of eligible survivors expressed interest in accelerometer participation98% of participants provided valid accelerometry dataMailing-based recruitment and return procedures were effective and acceptableSurvivors reported low burden and high acceptability of study participation

    10.1101/2025.10.04.25337334

    Nigg, C.; Mohr, D.; Schindera, C.; Brack, E.; Kuehni, C. E. Feasibility of 24-hour physical behavior monitoring with thigh-worn accelerometers after childhood cancer – the Swiss Childhood Cancer Survivor Study (SCCSS) – Activity 2025. https://www.medrxiv.org/content/10.1101/2025.10.04.25337334v1.

  • Thigh-worn sensor for measuring initial and final contact during gait in a mobility impaired population: A validation study

    Johnson, Thomas; Kuntapun, Janeesata; Childs, Craig; Kerr, Andy

    JMIR Biomedical Engineering

    Background: Measuring free-living gait with wearable sensors has great potential in supporting personalised rehabilitation. There are challenges meeting the accuracy levels of laboratory-based measurements in detecting initial and final contact, particularly in impaired populations.

    Objective:To test the criterion validity of a novel temporal gait measurement technique, combining the ActivPAL 4+ (PAL Technologies, Glasgow, UK) and the Teager-Kaiser Energy Operator, to measure stance phase duration in chronic stroke survivors through comparison with the Evoke cluster marker system (Vicon, Oxford, UK).

    Methods:Stroke participants (n=13, mean age = 59 years  14, time since stroke = 1.5 years  0.5) were assessed using the ACTIVPAL 4+ and a motion capture system. Two 10m walk tests were measured, while wearing two ActivPAL 4+ (located on anterior of both thighs) and clusters on the pelvis and ankles from the motion capture system. The Teager-Kaiser Energy Operator signal processing technique was used to extract the stance durations of the ActivPAL 4+, compared with a previously validated method.

    Results:There was a good agreement (bias: 0.03s, limits of agreement: -0.22 to 0.28s) between the ACTIVPAL 4+ and motion capture system despite a slight underestimation (mean stance time: 0.850s vs. motion capture system: 0.881s).

    Conclusions:Findings suggest the ACTIVPAL 4+, combined with Teager-Kaiser Energy Operator technique, provides valid stance time measurements when compared to laboratory-based systems, supporting its use in free-living gait analysis and feedback during rehabilitation. Limitations include laboratory-only validation and a small population of chronic stroke patients. Future work should explore free-living gait in a larger sample.

    10.2196/80308

    Johnson, Thomas; Kuntapun, Janeesata; Childs, Craig; Kerr, Andy Thigh-worn sensor for measuring initial and final contact during gait in a mobility impaired population: A validation study JMIR Biomedical Engineering 2025. 10.2196/80308.

  • Seeking to improve criterion and construct validity of retrospective self-reports of physical activity with brief reporting periods and quantitative response scales

    Stone, Arthur A.; Toledo, Meynard; Schneider, Stefan; Smyth, Joshua; Junghaenel, Doerte U.; Goldstein, Sarah; Pomeroy, Olivia

    Scientific Reports

    Self-reported information is central to many scientific fields and achieving high levels of validity for these data is paramount. Concerns have been voiced about the validity of retrospective self-reports because of possible distortion of recall by memory failures and cognitive heuristics. In this study we test two techniques with the potential to improve self-report validity: the use of brief reporting periods (near-momentary reports) and of quantitative response scales (duration in minutes). To evaluate validity, a set of self-reported physical activity outcomes were compared with objectively assessed physical activities. A total of 258 community-dwelling adults self-reported their momentary physical activity 5 times per day and wore accelerometers throughout 7 days; they also provided end-of-week assessments of physical activity. Regarding criterion validity, all self-reports indicated lower duration of sedentary behavior, however, momentary reports were closer in magnitude to accelerometry than were 1-week recall reports. All self-reports indicated greater duration of physical activity than accelerometry. Correlations between self-reports and accelerometry data were low to modest for momentary and retrospective reports; they were also low for reporting with quantitative versus relativistic, Verbal Response Scales, with the exception of momentary reports of sedentary duration (r = .61). Regarding construct validity, associations between most demographic variables and self-reports did not replicate those observed for accelerometry-based measures; in some cases, these associations showed opposite directions, indicating poor validity. In sum, apart from two criterion validity analyses showing higher validity for momentary reporting (compared with recall), the results did not support the hypotheses that the use of brief reporting periods and quantitative response scales improved validity over 7-day reporting and Verbal Response Scales, respectively. Particularly concerning was the poor performance of all methods in tests of construct validity.

    10.1038/s41598-025-16741-8

    Stone, Arthur A.; Toledo, Meynard; Schneider, Stefan; Smyth, Joshua; Junghaenel, Doerte U.; Goldstein, Sarah; Pomeroy, Olivia Seeking to improve criterion and construct validity of retrospective self-reports of physical activity with brief reporting periods and quantitative response scales Scientific Reports 2025. https://www.nature.com/articles/s41598-025-16741-8.

  • Enhancing Physical Activity Assessment In A French Large Cohort: Feasibility And Acceptability Of Wearable Accelerometers: 1686

    Vanhelst, Jérémy; Soumaré, Abdouramane; Bouchan, Jérôme; Bellicha, Alice; Touvier, Mathilde; Fezeu, Léopold; Oppert, Jean-Michel

    Medicine & Science in Sports & Exercise

    PURPOSE: The aim of this study was to assess the feasibility and acceptability of using three commercially available accelerometer devices in a subsample of the NutriNet Santé cohort. METHODS: Participants wore three accelerometers (FitBit®, ActivPal®, ActiGraph®) for seven consecutive days. Feasibility was assessed based on the accelerometer wear time data reported in a log dairy by participants. After the 7-day wear period, participants completed an online specific questionnaire with 19 items, regarding their acceptance of using each accelerometer. This questionnaire was developed based on the Technology Acceptance Model (TAM), which identifies the determinants of technology acceptance: perceived usefulness and perceived ease of use. A 5-point Likert scale was used on each item to express the level of agreement, ranging from 1 (strongly disagree) to 5 (strongly agree). RESULTS: From this ancillary study, 126 participants (62 men, 64 women), aged 46,3 ± 11,3 years were included. In terms of feasibility, all three accelerometers showed a high level of compliance with significant differences observed among them (p < 0.0001). The ActivPal® recorded the highest daily wear time (Median: 1440 minutes; 25th-95th centiles :1440 - 1440) followed by the FitBit® watch (Median: 1440 minutes; 25th-95th centiles :1421 - 1440) and the ActiGraph® (Median: 930 minutes; 25th-95th centiles :855 - 1020) (p < 0.0001). All participants validated their week of PA assessment (i.e at least 4 valid days), resulting in 1,049 valid days (person×days) for the ActivPal®, 1,046 (person×days) for the FitBit® watch, and 1,006 (person×days) for the ActiGraph®. The acceptability assessment based on the questionnaire showed that the FitBit® received the highest acceptability score (80,5 ± 8,13) and the ActiGraph® the lowest score (71,7 ± 8,68), although all three devices achieved an overall satisfactory score (p < 0.0001). CONCLUSIONS: Results from our study showed that the FitBit® watch is the most suitable device for measuring PA in free-living conditions in the NutriNet-Santé study. The large-scale use of such a device must now be evaluated in terms of logistics, cost, and data privacy.

    10.1249/01.mss.0001159160.44787.d5

    Vanhelst, Jérémy; Soumaré, Abdouramane; Bouchan, Jérôme; Bellicha, Alice; Touvier, Mathilde; Fezeu, Léopold; Oppert, Jean-Michel Enhancing Physical Activity Assessment In A French Large Cohort: Feasibility And Acceptability Of Wearable Accelerometers: 1686 Medicine & Science in Sports & Exercise 2025. https://journals.lww.com/acsm-msse/fulltext/2025/10001/enhancing_physical_activity_assessment_in_a_french.1176.aspx.

  • Comparison of Web-based Previous-Day Recalls and ActivPAL for Measuring Screen-based Sedentary Behavior by Segments of Day and Bouts in Chinese Young Males

    Zheng, Chen; Wong, Stephen Heung-Sang; Huang, Wendy Yajun

    Advanced Exercise and Health Science

    Background: The increase in screen-based sedentary behavior (SSB) has become a public concern. Several health outcomes have been found to be related to SSB, and their relationships with different types of SSB activities and duration of SSB bouts are different. This study aims to compare the SSB assessed through previous-day recall (PDR) with sedentary time (ST) measured through activPAL.

    Methods: Participants comprised 100 Chinese males aged 18–35 years, who wore an activPAL and completed web-based PDRs for seven consecutive days. Pearson’s correlations (r), intraclass correlations (ICC), and Bland–Altman plots were analyzed by day type (weekday, and weekend), segment of day (working time and leisure time), and duration of bouts (≥ 15, ≥ 30, and ≥ 60min).

    Results: The PDR assessed daily SSB was moderately correlated with activPAL assessed ST (r=0.35, 95% confidence interval: 0.27, 0.42). The correlations between two methods (both r and ICC values) were higher on weekends than on weekdays, and during leisure time than during working time. Low, but significant, correlations were found for sedentary bouts of ≥ 15min and ≥ 30min. Bland-Altman plots revealed −4.3h/day of mean difference (95% limits of agreement: −11.0, 2.6) between PDR assessed daily SSB and activPAL measured ST.

    Conclusions: In summary, there was a fair agreement between the SSB and ST. This Web-based PDR could be used as an easy and accurate tool to assess SSB, and SSB by day type, segment of day, and duration of bouts in young Chinese men.

    10.1016/j.aehs.2025.08.002

    Zheng, Chen; Wong, Stephen Heung-Sang; Huang, Wendy Yajun Comparison of Web-based Previous-Day Recalls and ActivPAL for Measuring Screen-based Sedentary Behavior by Segments of Day and Bouts in Chinese Young Males Advanced Exercise and Health Science 2025. https://www.sciencedirect.com/science/article/pii/S2950273X25000475.

  • Repeatability of Inertial Measurements of Spinal Posture in Daily Life

    Riddick, Ryan; Alshehri, Mansour Abdullah; Hodges, Paul

    Sensors

    Posture, physical activity, and sleep have been shown to be linked to many health issues but are difficult to assess in laboratories, especially in terms of long-term patterns. Worn on the body, inertial measurement units (IMUs) measure motion and have shown promise for longitudinal measurements of these phenomena, but the repeatability of their measurements in daily life has not been extensively characterized. This study assessed the repeatability of measures of spine posture and movement in a set of standardized tasks in the lab versus those performed at home using IMUs. We also evaluated issues that impact data quality for real-world measurements. The results showed moderate repeatability in the range of spinal motion assessed during the tasks (ICC = 0.67). In contrast, the absolute angles of the spine (such as the starting posture) were more variable and more difficult to estimate. The estimation of the reference posture was identified as a key factor. Five methods to estimate the reference posture were compared, and the use of a composite set of standardized tasks performed best (ICC = 0.72 ± 0.17). Additional studies and cross-validation with other sensors are needed to draw stronger conclusions about the optimal methodology. For measurements of daily life over 2 days, magnetic interference had a major impact on the data quality, affecting 43% of all data analyzed. Metrics were developed to assess data quality and strategies are proposed to improve repeatability in future work.

    10.3390/s25165011

    Riddick, Ryan; Alshehri, Mansour Abdullah; Hodges, Paul Repeatability of Inertial Measurements of Spinal Posture in Daily Life Sensors 2025. https://www.mdpi.com/1424-8220/25/16/5011.

  • From Verbal Reports to Personalized Activity Trackers: Understanding the Challenges of Ground Truth Data Collection with Older Adults in the Wild

    Khayami, Hossein; Wang, Lining; Kim, Young-Ho; Lee, Bongshin; Conroy, David E.; Lazar, Amanda; Choe, Eun Kyoung; Kacorri, Hernisa

    Proc. ACM Interact. Mob. Wearable Ubiquitous Technol.

    Tracking activities holds great potential to improve the well-being of older adults, yet the accuracy of activity trackers for this demographic remains in question. Evaluating this accuracy requires ground-truth data directly from older adults, which has largely been gathered in controlled laboratory settings or labeled by researchers. Moreover, considering the diversity in older adults’ activity engagement and tracking preferences, personalized activity tracking appears necessary. We demonstrate that older adults can benefit from personalized activity trackers by showing that cadence thresholds for stepping intensities vary within this group. However, collecting ground-truth data from older adults in real-world settings poses unique challenges. This paper examines two sources of ground-truth labels for the smartwatch Inertial Measurement Unit (IMU) data collected with older adults. Using verbal self-reports and a thigh-worn activity tracker, we assess their viability as ground-truth sources in natural settings. Additionally, we evaluate the costs and benefits of triangulating these sources as a ground-truth proxy. Our findings reveal two main costs: data shrinkage and notable effort from both contributors and data stewards. Simultaneously, we observe improved data quality and a greater ability to identify error sources when evaluating a trained model.

    10.1145/3731749

    Khayami, Hossein; Wang, Lining; Kim, Young-Ho; Lee, Bongshin; Conroy, David E.; Lazar, Amanda; Choe, Eun Kyoung; Kacorri, Hernisa From Verbal Reports to Personalized Activity Trackers: Understanding the Challenges of Ground Truth Data Collection with Older Adults in the Wild Proc. ACM Interact. Mob. Wearable Ubiquitous Technol. 2025. https://dl.acm.org/doi/10.1145/3731749.

  • Comparing the Accuracy of Different Wearable Activity Monitors in Patients With Lung Cancer and Providing Initial Recommendations: Protocol for a Pilot Validation Study

    Benzo, Roberto M.; Singh, Rujul; Presley, Carolyn J.; Tetrick, Macy K.; Chaplow, Zachary L.; Hery, Chloe M.; Yu, Jane; Washington, Peter; Penedo, Frank J.; Paskett, Electra D.; Lugade, Vipul; Fortune, Emma

    JMIR Research Protocols

    Background: Wearable activity monitors (WAMs) provide insights into physical activity (PA) and are widely used in behavioral interventions and cancer survivorship research. However, validation studies of wearable devices in populations with cancer are scarce, and existing studies using activity monitors in patients with cancer lack standardization. This gap is particularly significant in patients with lung cancer (LC), who often experience unique mobility challenges and gait impairments that may affect device accuracy. This study addresses this gap by validating the Fitbit Charge 6, ActiGraph LEAP, and activPAL3 micro in patients with LC in both laboratory and free-living conditions and developing a standardized framework for assessing wearable devices in populations with cancer and impaired mobility.

    Objective: This study aims to validate and compare the accuracy of consumer-grade (Fitbit Charge 6) and research-grade (activPAL3 micro and ActiGraph LEAP) WAMs in patients with LC under both laboratory and free-living conditions. Moreover, this protocol aims to establish standardized procedures that can be adapted for validating current and future generations of wearable devices while accounting for disease-specific factors that may impact measurement accuracy.

    Methods: In total, 15 adults diagnosed with LC (stages 1-4) will participate in laboratory and free-living protocols, wearing Fitbit Charge 6, activPAL3 micro, and ActiGraph LEAP devices simultaneously. The laboratory protocol will consist of a series of structured activities, including variable-time walking trials, sitting and standing tests, posture changes, and gait speed assessments. Activities will be video recorded for validation. In the free-living protocol, participants will wear the devices continuously for 7 days except during water-based activities. WAM-based outcome measures will include step count; time spent at light, moderate, and vigorous PA intensity levels; posture; and posture changes (only the activPAL3 micro measured posture). Validated survey instruments will be administered both before and after WAM data collection to control for potential confounding factors that may influence movement patterns and device accuracy. Laboratory-based validity measures will compare WAM data to video-recorded observations. Sensitivity, specificity, positive predictive value, and agreement will also be determined. Free-living agreement between devices will be assessed using Bland-Altman plots, intraclass correlation analysis, and 95% limits of agreement.

    Results: Data collection is ongoing, with 11 participants enrolled and 7 (64%) having completed both in-laboratory and free-living protocols. On average, enrolled participants are aged 63.0 (SD 7.8; range 50.0-73.0) years, with 8 (73%) participants being women. Participant enrollment is expected to conclude in mid-2025, and initial findings are expected to be disseminated by the end of 2025.

    Conclusions: This is the first study that validates WAM accuracy for populations with LC while providing comprehensive recommendations for future validation studies. This study will provide critical insights into the accuracy and reliability of WAMs for assessing PA in LC survivors, which are essential for interpreting clinical research and informing future interventions.

    10.2196/70472

    Benzo, Roberto M.; Singh, Rujul; Presley, Carolyn J.; Tetrick, Macy K.; Chaplow, Zachary L.; Hery, Chloe M.; Yu, Jane; Washington, Peter; Penedo, Frank J.; Paskett, Electra D.; Lugade, Vipul; Fortune, Emma Comparing the Accuracy of Different Wearable Activity Monitors in Patients With Lung Cancer and Providing Initial Recommendations: Protocol for a Pilot Validation Study JMIR Research Protocols 2025. https://www.researchprotocols.org/2025/1/e70472.

  • A smartphone application to measure walking cadence before major abdominal surgery in older adults.

    Rubin, Daniel Steven; Straczkiewicz, Marcin; Yamamoto, Emi; Madariaga, Maria Lucia L.; Ferguson, Mark; Brach, Jennifer S.; Glynn, Nancy W.; Lee, Sang Mee; Danilovich, Margaret; Huisingh-Scheetz, Megan

    Digital Biomarkers

    Background: Preoperative physical functional assessments (i.e., assessments that measure capability to perform physical activity) are integral to estimate perioperative risk for older adults. However, these assessments are not routinely performed in-clinic prior to surgery. Walking cadence, or the number of steps walked in a specified amount of time (i.e., steps/min), measures activity intensity and may be able to identify high-risk patients prior to surgery. Smartphones can measure walking characteristics and guide patients through remote functional assessments. Here we assess feasibility, acceptability and accuracy of Walk Test, a smartphone application designed to measure walking cadence.

    Methods: We performed a prospective cohort study of older adults prior to abdominal surgery and enrolled them remotely to perform at-home usual and fast-paced walks with subsequent validation in-clinic. Each walk (usual and fast-paced) was 2-minutes in duration. Feasibility was assessed if 80% of patients could perform all study procedures, acceptability was measured using the Post-Study Survey Usability Questionnaire (PSSUQ); accuracy of our approach was assessed with Lin’s Concordance Coefficient (CCC). activPAL thigh worn accelerometer worn during the in-clinic walk served as a gold standard comparison. We used the CCC to compare the at-home and in-clinic walks as performed by Walk Test.

    Results: We enrolled 41 participants (mean age 69±5 years, 26 (63%) female); 88% (36/41) successfully completed entire study protocol including independent installation of the application, walk tests (at-home and in-clinic) and questionnaires. Median (IQR) overall score of PSSUQ was 1 (1, 1) indicating strong acceptability and usability. The Lin’s CCC between the in-clinic activPAL and Walk Test for usual pace walk was 0.97 (95% CI: 0.96, 0.99, p <0.001) and for fast pact walks 0.96 (95% CI: 0.93, 0.98, p <0.001). The CCC between the at-home and in-clinic walks for usual pace walks was 0.70 (95% CI: 0.53, 0.86) and for fast-pace walks was 0.46 (95% CI: 0.21, 0.72).

    Conclusion: We successfully demonstrated the feasibility, acceptability and accuracy of Walk Test to measure walking cadence. Future work is needed to standardize walk test performance at-home to ensure consistency between in-clinic and at-home measures.

    10.1159/000545982

    Rubin, Daniel Steven; Straczkiewicz, Marcin; Yamamoto, Emi; Madariaga, Maria Lucia L.; Ferguson, Mark; Brach, Jennifer S.; Glynn, Nancy W.; Lee, Sang Mee; Danilovich, Margaret; Huisingh-Scheetz, Megan A smartphone application to measure walking cadence before major abdominal surgery in older adults. Digital Biomarkers 2025. https://doi.org/10.1159/000545982.

  • Criterion and Construct Validity of the Pocket-Worn RISE Device to Assess Movement Behaviour in Community-Dwelling People with Stroke

    January 2025

    Biemans, Camille F. M.; van der Heiden, Laura; Veenhof, Cindy; Verschuren, Olaf W.; Visser-Meily, Johanna M. A.; Pisters, Martijn F.; Hartman, Yvonne A. W.

    Sensors

    Accurate monitoring of physical activity (PA) and sedentary behaviour (SB) is crucial for tailoring interventions aimed at improving movement behaviour. This study evaluated the validity of the pocket-worn RISE device for measuring movement behaviour in community-dwelling patients with stroke. Criterion validity was assessed in a laboratory setting using video recordings. Construct validity was assessed in a free-living setting using the thigh-affixed ActivPAL. In the laboratory setting (25 participants, 66 ± 11.8 years), the RISE device showed good criterion validity for SB and PA. In the free-living setting (19 participants, 73 ± 10.2 years), the RISE device showed good construct validity for SB and PA, though further improvements could enhance the accuracy of individual-level measurements of moderate to vigorous physical activity (MVPA) and prolonged sedentary bouts. The mean absolute percentage error and mean percentage error were below the predefined 20% threshold for SB and PA. Intraclass correlation coefficients (ICCs) for SB and PA showed good reliability, but ICC ranges for prolonged sedentary bouts and MVPA were too broad to draw firm conclusions. These findings indicate the RISE device is well-suited for measuring SB and PA in free-living conditions. With real-time feedback, app compatibility, and pocket-wear convenience, the RISE device shows potential for behavioural interventions targeting movement behaviour in stroke and other chronic conditions.

    10.3390/s25113308

    Biemans, Camille F. M.; van der Heiden, Laura; Veenhof, Cindy; Verschuren, Olaf W.; Visser-Meily, Johanna M. A.; Pisters, Martijn F.; Hartman, Yvonne A. W. Criterion and Construct Validity of the Pocket-Worn RISE Device to Assess Movement Behaviour in Community-Dwelling People with Stroke Sensors 2025. https://www.mdpi.com/1424-8220/25/11/3308.

  • Relationship between step count and the Timed Up and Go and L-test of Functional Mobility among adults with transtibial amputation

    Leister, Kyle R.; Barreira, Tiago V.

    Archives of Physical Medicine and Rehabilitation

    Objective: To explore the relationship between daily steps measured by the activPAL 3 and Fitbit Inspire 3 accelerometers and performance on the Timed Up and Go test (TUG) and L Test of Functional Mobility (L test) in adults with transtibial amputation.

    Design: Observational design.

    Setting: Six outpatient prosthetic clinics located in the United States and the participant’s home environment.

    Participants: Adults (n=96) with unilateral transtibial amputation.

    Interventions: Not applicable.

    Main Outcome Measures: Each participant wore the activPAL and Fitbit concurrently for 7 days. Pearson correlation was used to assess the relationship between daily steps from each device and TUG and L test completion times. Regression was employed to control for sex, body mass index, age, and type 2 diabetes status.

    Results: Moderate negative correlations were observed between daily steps recorded by the activPAL and TUG (r=−.52) and L test (r=−.51) times. Moderate negative correlations were also found between daily steps from the Fitbit Inspire 3 and TUG (r=−.55) and L test (r=−.56) times. These relationships remained statistically significant with minimal influence by the included covariates.

    Conclusions: Participants who performed well on the TUG and L test tend to have higher daily step counts, highlighting a meaningful association between clinical mobility performance and free-living physical activity. This finding provides evidence that TUG and L test completion times may reflect both functional capacity in a clinical setting and real-world ambulatory behavior. Although step counts and clinical performance measures are not interchangeable, together they offer complementary insights that can enhance the evaluation and monitoring of mobility in individuals with transtibial amputation.

    10.1016/j.apmr.2025.04.007

    Leister, Kyle R.; Barreira, Tiago V. Relationship between step count and the Timed Up and Go and L-test of Functional Mobility among adults with transtibial amputation Archives of Physical Medicine and Rehabilitation 2025. https://www.sciencedirect.com/science/article/pii/S0003999325006562.

  • Wearable technology for mobility measurement in orthopedics and traumatology: a comparison of commercially available systems

    45731

    Keppler, A. M.; Zaccaria, R.; Weigert, M.; Keppler, L.; Böcker, W.; Neuerburg, C.; Schniepp, R.; Fürmetz, J.

    Archives of Orthopaedic and Trauma Surgery

    Background: Wearable activity sensors offer valuable insights into physical activity and are increasingly used in clinical and rehabilitation settings. However, most are designed for healthy individuals, necessitating a thorough evaluation of their applicability for pathological gait patterns. This study aims to assess the accuracy of commercially available wearables in measuring gait patterns among patients with lower limb injuries compared to healthy individuals. Methods: A prospective cohort study enrolled 40 participants divided into four groups: Group A (younger patients with lower limb injuries with age 75y). Mobility was assessed in real-world scenarios using four wearable devices (Apple Watch Series 4, Fitbit Charge 3, ActivPal 4, and StappOne Insoles V1.0) across three gait speeds in a gait laboratory, with GAITrite mats and video as gold standards. Results: Accuracy varied significantly between devices. The accelerometer-based wearables (Apple Watch Series 4, Fitbit Charge 3 and ActivPal 4™) underestimated cumulative step count compared to pressure-based Stappone v1. 0, especially for slow and restricted gait patterns (Groups C and D). Relative Difference of Wearables Measurements to the true numbers of steps (Group C: AW -21.83%, FB -28.99%, AP -20.00% versus SO 0.00% – Group D: AW -8.51%, FB -14.29%, AP -20.00% versus SO 4.55%). Zero measurements occurred frequently with wrist-worn devices, highlighting their limitations in detecting slow or restricted movements. In contrast, pressure-based StappOne Insoles demonstrated superior accuracy, with minimal deviations across all groups and gait speeds. The inaccuracy was exacerbated by factors such as the use of mobility aids, partial weight-bearing, and postoperative restrictions, which altered arm and leg movements. Conclusions: Accelerometer-based wearables require algorithmic improvements to address the challenges of slow and pathological gait patterns. The frequent occurrence of zero measurements with wrist-worn devices underscores their limited utility in clinical populations. Practical challenges, such as altered movement patterns due to mobility aids and partial weight-bearing, further limit their accuracy. Pressure-based systems, while accurate, face practicality issues for daily use. These findings emphasize the need for tailored wearable technologies for orthopedic and trauma patients.

    10.1007/s00402-025-05803-1

    Keppler, A. M.; Zaccaria, R.; Weigert, M.; Keppler, L.; Böcker, W.; Neuerburg, C.; Schniepp, R.; Fürmetz, J. Wearable technology for mobility measurement in orthopedics and traumatology: a comparison of commercially available systems Archives of Orthopaedic and Trauma Surgery 2025. https://doi.org/10.1007/s00402-025-05803-1.

  • Comparative Validity of Two Thigh-Worn Activity Monitors in Free-Living Conditions

    45701

    Duhamahoro, Jimmy; Lamoureux, Nicholas R.; Hibbing, Paul R.; Taylor, Matthew A.; Welk, Gregory J.

    Journal for the Measurement of Physical Behaviour

    Background: There is considerable interest in evaluating 24-hr activity cycles; however, the ideal tools for doing so have yet to be identified. Monitor-based approaches are widely endorsed for capturing movement, but novel methods are needed to assess the context of physical behaviors. This study evaluated the validity of two thigh-worn devices in assessing physical behaviors during a 24-hr period. Methods: 21 participants concurrently wore Move 4 and activPAL 3 microdevices on the thigh for a full day and then completed the Activities Completed over Time in 24 Hours recall survey. Equivalence tests (with activPAL as a reference) and mean absolute percent error were utilized to assess device agreement (at the minute and day levels) for energy expenditure (METs), steps, and time in different physical behaviors (moderate-to-vigorous physical activity, light physical activity, sedentary, and sleep). The Activities Completed over Time in 24 Hours data were used to evaluate the agreement in specific contexts. Findings: Devices had good agreement across 24-hr behaviors and for steps and METs at both day and minute levels. Estimates from the Move 4 were equivalent to activPAL for moderate-to-vigorous physical activity, sedentary, and steps, whereas METs, light physical activity, and sleep behaviors were not equivalent. The mean absolute percent error for METs in commonly reported activities ranged from 11.31% (watching television) to 20.88% (weightlifting). Conclusion: There was moderate-to-high convergent validity between Move 4 and activPAL in profiling 24-hr physical behaviors. The study highlights the value of combining device-based and report-based measures to evaluate physical behaviors over a 24-hr period. However, more research with larger and more diverse samples is warranted.

    10.1123/jmpb.2024-0034

    Duhamahoro, Jimmy; Lamoureux, Nicholas R.; Hibbing, Paul R.; Taylor, Matthew A.; Welk, Gregory J. Comparative Validity of Two Thigh-Worn Activity Monitors in Free-Living Conditions Journal for the Measurement of Physical Behaviour 2025. https://journals.humankinetics.com/view/journals/jmpb/8/1/article-jmpb.2024-0034.xml.

  • Real-time Sitting Correction Using Arduino-Based Ultrasonic Sensor at the Workplace

    Jameel, Huda Farooq

    Journal of Techniques

    People who work from home or in offices typically sit at a computer for most of their workday, often sitting with bad posture. Therefore, the decision was made to develop chairs to find a solution for the medical problems that arise from sitting for long periods during work. The intended audience for the chair includes office workers, students, and homemakers. Gamers who spend a lot of time sitting in their chairs could benefit from the technology. This research aims to solve the problem of unhealthy sitting. The hardware configuration includes a DC motor, power supply, microcontroller, ultrasonic sensor, buzzer, and a chair. The software configuration uses Arduino software to evaluate the system’s overall accuracy. Four categorization models are used: true positive, false positive, true negative, and false negative. The system development process has been exceptionally successful, achieving a total accuracy of approximately 97.434%. For future work, it is expected to increase the accuracy of the system with an IR sensor and speaker to alert the user.

    10.51173/jt.v6i4.1823

    Jameel, H. F. Real-Time Sitting Correction Using Arduino-Based Ultrasonic Sensor at the Workplace. Journal of Techniques 2024, 6 (4), 19–26. https://doi.org/10.51173/jt.v6i4.1823.

  • To Identify and Compare ActivPAL Objectively Measured Activity Levels With Self‐Reported Activity From the International Physical Activity Questionnaire in Older Adults With Intellectual Disability

    Lynch, Louise; McCarron, Mary; McCallion, Philip; Burke, Eilish

    Journal of Applied Research in Intellectual Disabilities

    Background: The positive impact of physical activity on health is widely known. A comparison between activPAL objective measures and International Physical Activity Questionnaire short form (IPAQ‐SF) self‐reported activity levels was completed with older adults with intellectual disability. Understanding differences between the two methodologies will better support the interpretations of findings and recommendations.

    Methods: ActivPAL measures including intensity, time and type were considered for 72 participants. Similarly, the IPAQ‐determined measures were investigated. Implications of different numbers of activPAL valid days were considered. Comparisons between the activPAL and IPAQ‐SF scores were examined using multiple correlation coefficients.

    Results: Low to moderate agreement was found between the activPAL and IPAQ‐SF using Spearman’s Rho and Pearson’s correlation coefficients.

    Conclusions: The IPAQ‐SF may not be the optimal tool for the accurate determination of activity levels in this population.

    10.1111/jar.13327

    Lynch, L.; McCarron, M.; McCallion, P.; Burke, E. To Identify and Compare ActivPAL Objectively Measured Activity Levels With Self‐Reported Activity From the International Physical Activity Questionnaire in Older Adults With Intellectual Disability. J Appl Res Intellect Disabil 2025, 38 (1), e13327. https://doi.org/10.1111/jar.13327.

  • Time in Bed Comparisons Between Two Automated Algorithms Applied to activPAL Data and Observations in a Polysomnography Lab

    Plekhanova, Tatiana; Maylor, Ben; Rowlands, Alex V.; Yates, Tom; Hall, Andrew P.; Davies, Melanie J.; Edwardson, Charlotte L.

    Journal for the Measurement of Physical Behaviour

    Objective: This study compared estimates of time in bed (TIB) and TIB start and end from two algorithms applied to activPAL data with observations of TIB in a polysomnography (PSG) lab.

    Methods: Twenty-five healthy volunteers (age: 32.4 ± 7.4 years, body mass index: 25.2 ± 3.7 kg/m2) wore a thigh-worn activPAL accelerometer during one-night laboratory-based PSG assessment. TIB and TIB start and end estimates were generated using automated algorithms within Processing PAL and PAL Technologies (PAL Batch software, version 8) applications. Agreement was determined using pairwise 95% equivalence tests (±10% equivalence zone), mean percentage absolute error, intraclass correlation coefficients (ICCs), and 95% limits of agreement.

    Results: The results for the algorithms were similar. TIB start and end were within the proposed ±10% equivalence zone of the PSG-lab observations, but TIB was not when using either algorithm. Mean percentage absolute errors for both algorithms were approximately 10%, 3%, and 1% for TIB and TIB start and end, respectively. Reliability between both algorithms and PSG lab was poor for TIB (ICC ≥ .39) and TIB start (ICC ≥ .38) and good for TIB end (ICC ≥ .81). Both algorithms recorded more TIB by about 42 ± 60 min and detected earlier TIB start and later TIB end by about 18 ± 62 and 14 ± 9 min, respectively, compared with PSG. Negative fixed biases (PSG–activPAL) were observed for TIB and TIB end from both algorithms (p < .05). For both algorithms, 95% limits of agreement were ±120 min for TIB and ±125 min for TIB start. Removing two outliers improved the agreement between both algorithms and PSG-lab observations.

    Conclusions: Processing PAL and PAL Technologies algorithms recorded more TIB by ∼40 min compared with PSG-lab TIB. Researchers should be aware of this discrepancy when using these algorithms and utilize predefined quality control protocols to enhance data quality. Future studies should continue refining these algorithms.

    10.1123/jmpb.2024-0023

    Plekhanova, T.; Maylor, B.; Rowlands, A. V.; Yates, T.; Hall, A. P.; Davies, M. J.; Edwardson, C. L. Time in Bed Comparisons Between Two Automated Algorithms Applied to activPAL Data and Observations in a Polysomnography Lab. Journal for the Measurement of Physical Behaviour 2024. https://doi.org/10.1123/jmpb.2024-0023.

  • A Treadmill-Based Evaluation of the Validity of the ActivPAL4 for Detecting Steps in Walking and Running in Healthy Adults

    Choi, Jordan; Hon, Sereen; Redpath, Louise; Wu, Chi Chian; Stansfield, Ben

    Journal for the Measurement of Physical Behaviour

    Objective: To accurately characterize people’s physical activity validated measurement devices must be used. The activPAL4 physical activity monitor allows measurement of stepping. A systematic approach was taken to validate the monitor for walking and running, across the walk to run transition.

    Methods: A cross-sectional sample of healthy young adults completed an incremental treadmill-based protocol (speeds 3.0–11.8 km/hr in 0.4 km/hr increments; 0.83–3.28 m/s). A video-based reference standard was used to evaluate the accuracy of the activPAL4 (thigh-mounted activity monitor) in detecting steps with mean percentage error, mean absolute percentage error, and agreement calculated. A linear regression modeled mean percentage error using sex, body mass index, height, cadence, and step length.

    Results: Thirty-six participants (25.6 ± 3.7 years, 18 M/18 F) transitioned from walking to running between 1.61 and 2.28 m/s. Mean percentage error between activPAL4 and video-based step count within speeds ranged from 1.6% to 4.3% for walking and 1.1% to 20.5% for running. Overall, walking step detection was good (mean absolute percentage error 3.1%), but steps were undercounted by the activPAL4 during running (mean absolute percentage error 14.5%). Regression modeling indicated that in walking for males activPAL4 undercounted by 2.85%, for females 1.79%. In running, for males activPAL4 undercounted steps by 13.3%, for females 15.6%. Sex and body mass index explained only a small amount of variance( ηp2<0.34). Cadence was the most important predictor of percentage error in running ( ηp2=.322) contributing to an adjusted R2 of .391.

    Conclusion: The activPAL4 measures walking steps well across the range of walking speeds from 0.83 to 1.94 m/s. Running steps were undercounted by the activPAL4 in relation to video-based observation between 10% and 20% between 1.83 and 3.28 m/s.

    10.1123/jmpb.2024-0024

    Conneely, M.; Sullivan, K. O.; Ryan, C.; Clifford, A.; Coote, S.; Eshghimanesh, Z.; Sullivan, V. O.; Robinson, K.; Shiely, F.; Glynn, L.; Woods, C.; Harmon, D.; Macken, P.; Meaney, R.; Phelan, M.; Centre, P. and P. I. P. of A. R.; McCreesh, K. Community-Based Exercise (ComEx Pain) for Older Adults with Chronic Musculoskeletal Pain: A Protocol for a Randomised Controlled Feasibility Trial. HRB Open Research November 15, 2024. https://doi.org/10.12688/hrbopenres.13981.1.