Tag: ICAMPAM

  • Free-Living Brisk Walking After Lower Limb Amputation: Functional Profiles Of Those Who Do And Do Not Achieve ≥100 Steps/Min

    Kline, Paul

    ICAMPAM 2026

    Objective: To compare functional mobility, self-reported mobility, and daily step counts between people with lower-limb amputation (LLA) who achieved brisk walking cadence during free-living activity and those who did not. Methods: Sixteen adults with unilateral LLA participated (11 male, age 56 ± 13 years; 12 transtibial, 4 transfemoral). Physical function was assessed using gait speed, dual-task gait speed, Timed Up-and-Go (TUG), and the Two-Minute Walk Test. Self-reported mobility was measured with the Activities-specific Balance Confidence Scale. Daily step counts were collected using thigh-mounted accelerometry over 10–14 days (activPAL4). Participants were classified based on whether they accumulated at least one minute of brisk walking (≥100 steps/min). Brisk-walking duration was derived from 1-minute stepping epochs by calculating average cadence for each walking minute. Independent t-tests compared characteristics between groups. Results: Six participants did not achieve any brisk walking. Among the ten who did, mean brisk-walking time was 4 ± 5 minutes/day. The brisk-walking group demonstrated significantly faster TUG times (9.1 ± 1.4 vs 10.9 ± 1.1 s, p = 0.02). No between-group differences were observed in age, body mass index, time since amputation, comorbidity count, self-reported mobility, or total daily steps. Conclusions: Individuals with LLA who achieved brisk cadence were largely similar to those who did not across demographic, functional, and activity measures. Although TUG performance differed, both groups averaged times below thresholds associated with poor mobility. These findings suggest that behavioral strategies encouraging higher walking cadences rather than additional rehabilitation targeting physical capacity may help people with LLA engage in more brisk walking during daily life.

    Kline, Paul Free-Living Brisk Walking After Lower Limb Amputation: Functional Profiles Of Those Who Do And Do Not Achieve ≥100 Steps/Min NA 2026. NA.

  • Physical Activity And Sedentary Behavior Profiles During Objectively Measured Smartphone Use In University Students

    Schmidt, Michael; Boudreaux, Benjamin D.; Frederick, Ginny M; O’Connor, Patrick; Evans, Ellen

    ICAMPAM 2026

    Objective: To examine differences in device measured sedentary [SED], light intensity PA [LPA], and moderate-vigorous intensity PA [MVPA] behavior during bouts with or without smartphone screen time [SST]. Methods: University students (n=104, 20.2±1.7y, 66% female) simultaneously wore a 1) ActiGraph GT9X on the wrist, 2) activPAL3 on the thigh, and 3) ActiGraph GT3X on the hip for 7-10 days to capture 24-hr sleep, SED and LPA/MVPA, respectively. SST was passively recorded in 5-minute epochs using the RescueTime application over the same period. Epochs in which 4+ min of SST occurred were classified as SST bouts, while epochs with 0 min of SST were classified as non-SST bouts. Partial bouts of SST (0.1-3.9 min) were excluded from this analysis. Activity behaviors were summed across all SST and non-SST bouts for each day and converted to percent time spent in each behavior and averaged for participants with at least two weekdays and one weekend day of device/SST data. Paired t-tests assessed the statistical significance of differences in activity behaviors during SST and non-SST and whether differences varied on weekdays vs. weekend days or by sex. Results: SST was mostly comprised (mean±SD) of SED (80.7±10.3%), with limited LPA (16.4±8.7%) and low MVPA (2.0±2.4%). Significantly more activity occurred during non-SST [SED (61.4±11.3%), LPA (32.8±10.4%), MVPA (5.9±4.0%), all p<.0001]. Differences during SST vs. non-SST were larger on weekend days for all measures, but only significantly so for LPA (p=.04). Reductions in MVPA during SST were significantly greater (p=.003) in males (-5.4±4.0%) than in females (-3.1±3.4%) but differences in SED and LPA were similar across sex. Conclusions: A comparison of device measured PA patterns during SST and non-SST bouts found a 20% higher proportion of time in SED, and substantially lower LPA and MVPA, during SST bouts. Larger adverse differences in some PA behaviors during SST were observed on weekend days and in males.

    Schmidt, Michael; Boudreaux, Benjamin D.; Frederick, Ginny M; O’Connor, Patrick; Evans, Ellen Physical Activity And Sedentary Behavior Profiles During Objectively Measured Smartphone Use In University Students NA 2026. NA.

  • Evaluating Open-Source Wrist-Worn Accelerometer Models For Sedentary Time Classification Against Thigh-Worn Accelerometer Data

    Acquah, Aidan; Broomberg, Katya; Healy, Genevieve; Dunstan, David; Edwardson, Charlotte; Doherty, Aiden; Davies, Melanie; Maylor, Benjamin

    ICAMPAM 2026

    Prolonged sedentary time is associated with adverse health outcomes, and wearable devices can provide useful insights into these associations. While accelerometers worn on the thigh provide a widely accepted reference standard for sedentary time, wrist-worn devices, despite poorer activity classification accuracy, remain substantially more popular than thigh-worn devices, allowing for easier scalability for large-scale population studies. This study aimed to evaluate the ability of open-source, activity recognition models, deployed on wrist-worn accelerometer data, to classify sedentary time, with thigh-worn data as the reference standard. We analysed data from the SMART Work and Life dataset, comprising over 700 working-age adults, aged 20 – 70 years (mean age 45 years; 72% female), who concurrently wore wrist-worn Axivity AX3, and thigh-worn activPAL accelerometers, under free-living for up to 8 days. Sedentary time from the activPAL was identified using PAL Technologies proprietary algorithm. Axivity data were processed using several widely used cutpoint-based and machine learning models. Model performance was assessed at 30-second epochs against the thigh-derived reference labels. Machine learning approaches outperformed all cutpoint-based methods explored, with OxWearables’ ActiNet and Accelerometer models achieving the best performance. Per participant accuracy was 0.87 ± 0.05 and 0.84 ± 0.05, with F1 scores of 0.84 ± 0.11 and 0.81 ± 0.11, respectively. The Actimetric Trost random forest model achieved intermediate accuracy (0.73 ± 0.06), outperforming the cutpoint-based models, each with accuracy of 0.72 ± 0.07. These findings demonstrate that wrist-worn accelerometers, when combined with machine learning models, can accurately identify sedentary time with performance approaching that of thigh-worn devices. However, further research is required to reduce classification errors and improve model generalisability across diverse populations.

    Acquah, Aidan; Broomberg, Katya; Healy, Genevieve; Dunstan, David; Edwardson, Charlotte; Doherty, Aiden; Davies, Melanie; Maylor, Benjamin Evaluating Open-Source Wrist-Worn Accelerometer Models For Sedentary Time Classification Against Thigh-Worn Accelerometer Data NA 2026. NA.

  • Towards Harmonised Accelerometer-Derived Physical Activity: A Comparative Study Across Wrist, Thigh, And Hip Wear Locations

    Zisou, Charliaos; Maylor, Benjamin; Acquah, Aidan; Rowlands, Alex; Healy, Genevieve; Dunstan, David; Davies, Melanie; Yates, Tom; Edwardson, Charlotte; Straker, Leon; McVeigh, Joanne; Hopewell, Jemma; Doherty, Aiden

    ICAMPAM 2026

    Background: Wearable devices are widely used in epidemiological studies, but differences in wear locations make data harmonisation and pooling in international consortia challenging. We aimed to 1) assess the agreement of movement behaviours derived from wrist, thigh, and hip-worn accelerometers in free-living adults, and 2) derive regression equations to enable harmonisation across wear locations. Methods: Raw accelerometer data were analysed from two free-living adult datasets; the SMART Work and Life (SWAL) study included UK office workers who wore wrist and thigh accelerometers (Axivity AX3 and activPAL3) for eight days, and the Raine Generation 1 study included Australian adults who wore wrist and hip accelerometers (ActiGraph GT3X) for eight days. Wrist, thigh, and hip data were processed using OxWearables software, PALbatch, and ActiLife, respectively, to extract different aspects of movement behaviour. Consistency across wear locations was assessed using intraclass correlation coefficients (ICCs), and standardised major-axis regression was used to derive harmonisation equations. Results: Analyses included valid data from 690 SWAL participants (mean age 44.7 years; 72% women) and 930 Raine participants (mean age 56.7 years; 57% women). Wrist and thigh-worn measures showed moderate-to-good consistency, with ICCs ranging from 0.64 for sedentary time to 0.89 for step count. Wrist and hip consistency ranged from 0.59 for overall activity to 0.86 for peak 1-min cadence, while sedentary time showed poor consistency (ICC 0.36). Restricting analyses to waking hours (8am-10pm) did not materially affect most measures, but substantially improved wrist-hip sedentary time agreement (ICC 0.72). Conclusion: Movement behaviours derived from wrist, thigh, and hip locations show moderate-to-strong correlations. These findings support the development of location-agnostic processing approaches to improve harmonisation and pooling of accelerometer data across studies.

    Zisou, Charliaos; Maylor, Benjamin; Acquah, Aidan; Rowlands, Alex; Healy, Genevieve; Dunstan, David; Davies, Melanie; Yates, Tom; Edwardson, Charlotte; Straker, Leon; McVeigh, Joanne; Hopewell, Jemma; Doherty, Aiden Towards Harmonised Accelerometer-Derived Physical Activity: A Comparative Study Across Wrist, Thigh, And Hip Wear Locations NA NA. NA.

  • Evaluating Device Agreement Between Actigraph And Activpal: Systematic Bias And Sex Differences In Steps, Sedentary Time, And Moderate-To-Vigorous Physical Activity

    Hargens, Trent; Morrow, Emma; Harkin, Ainsley; Cawley, Makayla; Edwards, Elizabeth

    ICAMPAM 2026

    OBJECTIVE: The 2018 Physical Activity Guidelines Advisory Committee called for additional research examining agreement between devices used to assess physical activity and sedentary behavior. The ActiGraph (AG) and ActivPAL (AP) are two accelerometers frequently employed in research; however, whether sex influences agreement between these devices has not been thoroughly investigated. METHODS: A total of 76 adults [48 women, 28 men, aged 18 – 65 yr (36 ± 15 yr)] wore the AG and AP concurrently for 4 – 9 days. The AG was positioned on the right hip and the AP on the right thigh. Bland-Altman analyses in all subjects were used to assess systematic bias and limits of agreement between AG and AP. Intraclass correlation coefficients (ICC), mean differences (MD), and mean absolute percentage error (MAPE) values were calculated by sex. Sex differences in device agreement were evaluated using independent sample t-tests on mean values and Welch’s t-tests on participant level bias (mean differences) and error magnitude (MAPE). RESULTS: Bland-Altman analyses showed AG underestimated steps (~850/day), overestimated sedentary time (~70 min/day), and demonstrated poor agreement for MVPA. Step counts and sedentary time differed significantly between devices in both sexes (P<0.001), while MVPA differences reached significance in women only. ICC values indicated excellent agreement for steps (0.91 – 0.96), good agreement for sedentary time (0.84 – 0.88), and moderate agreement for MVPA (0.63 – 0.74). Welch’s t-tests on participant level bias and MAPE showed no significant sex differences in device agreement. CONCLUSIONS: The AG and AP demonstrated consistent bias by underestimating steps, overestimating sedentary time, and showing poor agreement for MVPA, but overall agreement was strong for steps, moderate for sedentary time, and did not differ significantly by sex.

    Hargens, Trent; Morrow, Emma; Harkin, Ainsley; Cawley, Makayla; Edwards, Elizabeth Evaluating Device Agreement Between Actigraph And Activpal: Systematic Bias And Sex Differences In Steps, Sedentary Time, And Moderate-To-Vigorous Physical Activity NA 2026. NA.

  • Translating Lab-Based Mobility Measures Into Free-Living Physical Behavior In Chronic Post-Stroke Adults With Aphasia

    Mendoza, Albert; Thompson, Christian; Ghafury, Ferdaus; Cooper, Stephanie; Leyvas, Jade; Gravier, Michelle; Sasadeusz, Kaitlyn; Pitsch, Erica; Halabi, Cathra; Ivanova, Maria

    ICAMPAM 2026

    Laboratory-based assessments are commonly used to characterize mobility and aerobic capacity after stroke, but their relevance to everyday movement in adults with aphasia is unclear. Purpose: To examine associations between laboratory-based measures of functional capacity and aerobic fitness and free-living physical behavior in adults with chronic post-stroke aphasia. Methods: Thirteen chronic post-stroke adults with aphasia completed laboratory assessments of lower-body functional capacity and aerobic fitness, along with 7 consecutive days of free-living monitoring using a thigh-worn activPAL4 pro (on most active leg). Average Western Aphasia Battery–Aphasia Quotient score – was 80.5 ± 10.7, with scores ranging from 63.1 (moderate) to 93.3 (mild). Valid wear days were defined as ≥10 h/day. Participants provided an average of 6.4 valid days with 23 h 56 min/day of wear, yielding 1,986 h of free-living data. Free-living outcomes included daily stepping volume, cadence-defined walking behavior, sit-to-stand transitions, and peak 30-min cadence. Spearman correlations quantified associations between laboratory measures and free-living physical behavior. Results: Peak 30-min cadence was strongly related to time spent walking at higher cadences (ρ = 0.65–0.85). Brisk 10-m gait speed was moderately associated with daily step count and peak 30-min cadence (|ρ| ≈ 0.64–0.65). Chair-stand performance showed minimal association with daily sit-to-stand transitions (ρ ≈ 0.05). Maximal aerobic capacity showed a modest association with daily sit-to-stand transitions (ρ ≈ 0.50) but weak associations with overall stepping volume (|ρ| ≤ 0.10). Conclusion: Commonly used laboratory measures of functional capacity and aerobic fitness show limited correspondence with habitual free-living physical behavior in chronic post-stroke adults with aphasia. Significance: These baseline findings highlight the importance of pairing laboratory assessments with device-based measures of daily behavior to improve translational inference and intervention targeting.

    Mendoza, Albert; Thompson, Christian; Ghafury, Ferdaus; Cooper, Stephanie; Leyvas, Jade; Gravier, Michelle; Sasadeusz, Kaitlyn; Pitsch, Erica; Halabi, Cathra; Ivanova, Maria Translating Lab-Based Mobility Measures Into Free-Living Physical Behavior In Chronic Post-Stroke Adults With Aphasia NA 2026. NA.

  • Accelerometer-Derived Activity Responses To Exercise Snacks In Type 2 Diabetes: Secondary Analyses Of Acute And Chronic Randomized Trials

    Sandilands, Roderick; Marcotte-Chénard, Alexis; Babir, Fiona J.; McCarthy, Seth F.; Maylor, Benjamin; Ahmadi, Matthew; Mulkewich, Noah; D’Amico, Angelina; Stamatakis, Emmanuel; Islam, Hashim; Gibala, Martin J.; Little, Jonathan

    ICAMPAM 2026

    Objective: Exercise snacks (ExSnacks) are a practical strategy to increase vigorous physical activity (VPA), yet their effects on accelerometer-derived activity metrics in people with type 2 diabetes (T2D) is unclear. Methods: This work integrated two randomized crossover studies (Studies 1 and 2), and a 12-week parallel-arm randomized controlled trial (Study 3). Studies 1 and 2 tested the acute effects of ExSnacks (n=32; 57±11 years) or low-intensity stretching exercise (LOW) (n=36; 58±10 years) versus no exercise. Participants completed two days with prescribed 4×1-minute bouts distributed across the day and two days without exercise. Study 3 compared the same ExSnacks (n=32; 57±11 years) with LOW (n=39, 58±10 years) prescription performed by participants unsupervised at home or work aiming for ≥20 bouts/week. Thigh-worn activPAL4 accelerometers were used throughout Studies 1 and 2, and for ≥4 days at baseline and Week 11 in Study 3, with raw accelerometer data processed using GGIR. Effect estimates presented as % difference [95% CI] except for the intensity gradient (IG; difference at Week 11 [95% CI]) were derived using linear mixed models in Studies 1 and 2 and using constrained baseline longitudinal data analysis using linear mixed models in Study 3 to minimize variance at baseline. Results: In Study 1, ExSnacks increased IG (-0.10 [-0.01, -0.18], P=0.041), raised acceleration intensity across the most active 1-60 minutes (all P<0.05), reduced time in the 0-50mg acceleration bin (-20 [-30, -9], P=0.002), and increased time in bins 50-100, 250-300, 300-350, 350-400, and >400mg (all P<0.05 versus no exercise). In Study 2, LOW did not differ from no exercise (all P>0.05). In Study 3, ExSnacks increased acceleration intensity in the most active 1–5 minutes (P<0.05) and time in the >400mg bin (66 [29, 102], P<0.001) at Week 11 versus LOW. Conclusions: Exercise snacks may be a viable method to increase vigorous activity intensity and volume in individuals with T2D. This work was funded by Diabetes Canada.

    Sandilands, Roderick; Marcotte-Chénard, Alexis; Babir, Fiona J.; McCarthy, Seth F.; Maylor, Benjamin; Ahmadi, Matthew; Mulkewich, Noah; D’Amico, Angelina; Stamatakis, Emmanuel; Islam, Hashim; Gibala, Martin J.; Little, Jonathan Accelerometer-Derived Activity Responses To Exercise Snacks In Type 2 Diabetes: Secondary Analyses Of Acute And Chronic Randomized Trials NA 2026. NA.