Winkler, EAH; Healy, GN; Chastin, SFM
3rd International Conference on Ambulatory Monitoring of Physical Activity and Movement
INTRODUCTION: Automated estimation is a low-burden method to estimate accelerometer non-wear that is essential for large-scale studies. However, no published research to date demonstrates the validity of automated estimation algorithms for activPAL data. Removing non-wear and sleep from activPAL data has required the use of self-report data or untested approaches, such as assuming the longest bout of sitting/lying each day is sleep and assuming periods of at least 60 minutes of zero acceleration are non-wear. PURPOSE: Using baseline data from a workplace sitting intervention, we compared several automated estimation algorithms with self-reported worn waking time. METHODS:Office workers (n=43) were asked to wear activPALs continuously for seven days and report their sleeping and removal times in a diary. For the referent assessment method, each bout from the activPAL events files was classified as awake (or asleep) and removed (or worn) depending on whether or not most (i.e., >=50%) of the bout fell into those classifications according to self-report. Six different automated estimations were implemented and compared with the referent assessment method: at least 60, 90, 120, 240 and 360 minutes of continuous sitting/lying and at least 60 minutes of continuous zero acceleration. Bland-Altman analysis assessed agreement in daily worn waking time and Kappa assessed agreement of the wear classification of each bout. As misclassification is most problematic for the longest bouts, Kappa was assessed with weighting for bout duration (in minutes). RESULTS:Prolonged zero acceleration classified all time as worn waking time. The smallest mean differences [95% Limits of Agreement] in daily worn waking time against the referent method were provided by 60 and 90 minutes of continuous sitting/lying (-31 [441, 379] and 41 [-350, 433] minutes, respectively). The best agreement in wear classification was provided by 90 and 120 minutes of continuous sitting/lying (Kappa [Standard Error] = 0.75 [0.03] and 0.75 [0.04], respectively). CONCLUSION: Automated estimation of worn waking time based on prolonged sitting/lying may be useful for large-scale studies employing activPALs, with 90 minutes being the most supported minimum non-wear period. The level of accuracy is acceptable and comparable to automated estimation with other accelerometer data. Wider validation in more general populations is needed. Grant funding: This study was funded by an NHMRC project grant [#1002706], with additional financial support from the Victorian Health Promotion FoundationWinkler, EAH; Healy, GN; Chastin, SFM Validity of Automated Estimation of Worn Waking Time for ActivPAL Data 3rd International Conference on Ambulatory Monitoring of Physical Activity and Movement 2013. http://www.umass.edu/sphhs/sites/default/files/ICAMPAM_Slide_Poster_Composite_6.6.pdf.