Can the ActivPAL accurately measure walking under challenging conditions in peoplewith PD?

Lamont RM, Morris ME, Woollacott MH, Brauer S

ISPGR/GAIT & Mental Function 1st Joint World Congress Trondheim, Norway 24 28 June 2012 (p 20)

BACKGROUND AND AIM: Maintaining walking ability is an important health goal for people with PD and therefore important to assess. Current methods of walking in the community are either time consuming (observation) or unreliable (self report). The ActivPAL (Pal Technologies, Glasgow, UK) is a small lightweight uniaxial accelerometer which has been used to measure stepping time, number of steps, position changes and sedentary activity in older people and people with PD. The purpose of this study was to assess the accuracy and test?retest reliability of the ActivPAL to measure time spent stepping and the number of steps taken while walking for shorter and longer durations and with a variety of walking challenges. METHODS: Walking was assessed in 62 people with PD while walking at a comfortable pace over 10 metres, for 3 minutes and 6 minutes. Ten metre and 6 minute walks were conducted with minimal distractions and while performing no other tasks. During the 3 minute walk, participants walked in a busy public area while conducting a conversation and negotiating doorways, obstacles and surface changes. Time spent stepping and number steps taken was measured using the activPAL, a stop watch (time) and manual counting (steps). Participants attended a second assessment 4?7days later where the 10 metre and 6 minute walks were repeated. RESULTS: The activPAL showed excellent accuracy when measuring time spent stepping across all three walking conditions with ICC’s ranging from r=0.92?0.99. When measuring number of steps, the activPAL was accurate across all three walking conditions being most accurate for the 6 minute walk (ICC r=0.99) and least for the 10 metre walk (ICC r= 0.88). Test retest reliability was also good with ICC’s ranging from r=0.63 to 0.76 for time and r=0.76 to 0.84 for steps. CONCLUSIONS: The activPAL is an accurate way of assessing time spent stepping and number of steps across short and longer duration walks and in a variety of environments and thus may be a promising tool for measuring volume of walking in the community. This study was supported by NHMRC project grant ID#5121170, CIA Brauer. REFERENCES: 1. Busse, M., et al. J Med Eng Tech, 2009. 33(1): p. 33?41. 2. Chastin, S., et al. Movt Dis, 2010. 25(13): p. 2114?20.

NA

Lamont RM, Morris ME, Woollacott MH, Brauer S Can the ActivPAL accurately measure walking under challenging conditions in peoplewith PD? ISPGR/GAIT & Mental Function 1st Joint World Congress Trondheim, Norway 24 28 June 2012 (p 20) 2012. http://ispgr.silkstart.com/down/eJwFwQEKgCAMAMAfbasxLX!zlCjKFDcIen13h3tPiHbel7kOB2PQql979DXIraKQhlCWLMwrRZk4Es0sG@Sy@6LUE6k=/Norway%202012_Abstracts.pdf.