Anuradha, S; Adam, O; Winkler, E; Dunstan, DW; Owen, N; Healy, GN
2011 ICAMPAM
INTRODUCTION Newer activity monitors that can provide an objective record of movement and posture, particularly incidental activity, are now available. However, little is known about the validity of these devices in assessing sedentary behaviour and light-intensity activity. We compared the accuracy of two commercially-available devices in measuring sedentary and light-intensity activity: the activPAL, a validated inclinometer; and, the ActiGraph GT3X-plus activity monitor, which includes an inclinometer as well as raw acceleration-data collection capabilities in three axes. METHODS Eighteen adults (5 men; age range 22-58 years; mean BMI 24.8kg.m-2 [SD 4.7]) were fitted with an activPAL and three GT3X-plus monitors, one each on their hip, dominant wrist and dominant ankle. They completed three office-based tasks (five minutes each of typing, listening to a presentation, talking on telephone) while sitting and while standing, and walked within the premises at their normal walking pace for five minutes. They were also required to sit still, stand still and walk on a treadmill at 3.2 and 5.4 kph (two minutes each). Agreement of the inclinometer function of the activPAL and GT3X-plus devices with the experimental protocol was calculated using the Kappa statistic (K); 95% confidence intervals were obtained using cluster bootstrap method. Acceleration data were compared for sitting, standing and walking. RESULTS Agreement was very high for the activPAL for sitting (K=0.99, 95% CI: 0.97, 1.00), standing (K=0.98, 95% CI: 0.96, 1.00) and walking (K=0.99, 95% CI: 0.99, 1.00). Agreement was modest for the GT3X-plus when worn on the hip, wrist, and ankle, for sitting (K=0.30, 95% CI: 0.15; 0.45, K=0.26, 95% CI: 0.20, 0.32; K=0.48, 95% CI:0.32, 0.63) and for standing/walking (K=0.37, 95% CI: 0.26; 0.49, K=0. 32, 95% CI: 0.27, 0.37; K=0.48, 95% CI:0.32, 0.63). Counts in each axis and vector magnitude units (VMU) were all significantly higher (p<0.05) for walking than for sitting or standing. Significant differences (p<0.05) between sitting and standing were only noted for axis 1 and axis 2 (hip position) and for axis 2 and VMU (ankle position).Anuradha, S; Adam, O; Winkler, E; Dunstan, DW; Owen, N; Healy, GN Comparison of activPAL and GT 3X-plus in Distinguishing Sitting, Standing and Walking in Typical Office-Based Activities 2011 ICAMPAM 2011. http://www.umass.edu/sphhs/documents/ConferencebookICAMPAM2011.pdf.