Grant PM, Ryan CG, Tigbe WW, Granat MH
6th International Conference on Dietary Assessment Methods (ICDAM6) “Complementary advances in diet and physical activity assessment methodologies”, Copenhagen, Satellite meeting: Objective Measurement of Physical Activity, University of Southern Denmark,
Introduction Objective information about activity patterns and the amount of physical activity undertaken in the population is needed to provide appropriate recommendations for health programmes. However, even with recent advances in technology allowing for the use pedometery and accelerometery, accurate measurement of physical activity remains problematic. The activPAL professional physical activity monitor (PAL Technologies Ltd, Glasgow, UK), is a single unit device, requiring no calibration, that identifies in real time, episodes of walking, sitting and standing allowing the measurement of both activity and inactivity. In addition, the monitor records step number and instantaneous cadence.The studies aimed to evaluate the validity and reliability of the activPAL monitor as a measure offree?living activity. Study 1 Method Ten adults wore three activPAL monitors to carry out everyday activities. Activities were videoed and classified by three observers into sitting, standing and walking. Data from the activPAL similarly classified and compared to those of observation (criterion method). Results Inter?observer reliability [ICC (1)] was excellent (>0.97) and inter?device reliability [ICC (1)] good excellent (0.78?0.99). Agreement between activPAL and observation by the Bland?Altman method (2) was good?excellent, mean difference of ?2.0% to 0.2% (limits of ?16.1% to 12.1%). Second?by second analysis yielded a percentage agreement of 95.9% with sensitivity and predictive values 88.1% to 99.6% for different activities. Study 2 Method Step?count and cadence in 20 adults (12F, 8M) were evaluated during treadmill walking for five different speeds and outdoor walking at three self selected speeds. Trials were videoed and observation used as the criterion measure. Each participant wore four activPAL monitors. Results Inter?device reliability [ICC (1)] was ?0.99 for step?count and cadence. Agreement by Bland? Altman method (2), between the activPAL and observation, was excellent for step?count and cadence at all speeds, mean difference of 0% ? 1.0% (limits of ?2.6% to +3.2%). Conclusion The activPAL activity monitor is a valid and reliable objective measure of free?living physical activityGrant PM, Ryan CG, Tigbe WW, Granat MH Objective measurement of free-living physical activity using the activPAL monitor 6th International Conference on Dietary Assessment Methods (ICDAM6) “Complementary advances in diet and physical activity assessment methodologies”, Copenhagen, Satellite meeting: Objective Measurement of Physical Activity, University of Southern Denmark, 2006. NA.