An exploration of the activPAL activity monitor in measurement of sedentary and physical activity patterns in people with mild to moderate Parkinson s disease: A validation study

Donnelly B

SPARC Conference 26 October 2016, Edinburgh; Abstract 33, p 76

Background Parkinson s disease (PD) is a neurodegenerative disorder that affects approximately 127000 people in the UK. People with PD (pwPD) often demonstrate sedentary behaviour (SB), however, physical activity (PA) has neuroprotective properties and can modify the progression of symptoms. Measurement of PA and SB may facilitate individually-tailored interventions and accelerometry has been suggested as a practical and objective measurement tool. Aim This study aims to investigate the validity of the activPAL accelerometer in measuring PA and SB in pwPD with direct observation as the criterion measure. Methods This study was part of on-going research being undertaken by the project supervisors, Dr Jane Hislop and Dr Gill Baer. Ethical approval for this study was obtained from the Queen Margaret University, Divisional Research Ethics Committee. Eight men and two women (mean age 69 7.3) with PD (median Hoehn and Yahr 1.5, IQR 12) were recruited from a local Parkinson s UK group. All subjects were videoed while they undertook a series of structured and free-living activities while wearing an ActivPAL accelerometer. The time spent in different postures was classified. This was aligned and compared with the activPAL output data. Results The activPAL has a low percentage error for SB (9.11% and 3.37%) and a higher percentage error for PA (-15.1% and -19.63%). There was no statistically significant correlation between the activPAL and observation during controlled activities (r=0.68, p=0.03 and r=0.55, p=0.098), however, high correlation during free-living section (r=0.94, p<0.001 and r=0.99, p<0.001). Wide limits of agreement (LOA) (range-112.6s 106s) were demonstrated between the activPAL and observation throughout the whole test. Discussion This is the first study to examine the criterion validity of the activPAL accelerometer in measuring PA and SB in pwPD. It is suggested that the activPAL overestimates SB and underestimates PA. Correlation analysis suggested very high correlation between variables in free-living section and low correlation during controlled activities. However, the method of Bland and Altman is required to demonstrate differences between variables and is the preferred technique to establish validity. Wide LOA between the activPAL and observation for both PA and SB suggests a minimum of 8.7% of the mean test-time (7.45min) was inaccurately recorded. Reallocating 30 minutes of SB to PA a day could result in an improvement in PD symptoms, therefore, wide LOA could be considered unacceptable. However, a sample size of greater than 50 is recommended, otherwise the LOA may be artificially widened. The small sample size has resulted in the study having low statistical power and reduced external generalisability. A laboratory-based setting introduced an element of control in to the free-living ADL section and the module became semi-constrained. The mean completion time of 7.45 minutes could be considered excessive and not representative of daily life. Further research could be conducted using a body-worn camera to establish the validity in pwPD in a life-like environment Conclusion Further research is warranted to validate the activPAL before its use in practice.

10.1186/s12877-021-02083-3

Donnelly B An exploration of the activPAL activity monitor in measurement of sedentary and physical activity patterns in people with mild to moderate Parkinson s disease: A validation study SPARC Conference 26 October 2016, Edinburgh; Abstract 33, p 76 2016. NA.