MacMillan, F; Rowe, DA; Grant, PM; Granat, MH; Mutrie, N
2nd ICAMPAM
INTRODUCTION Pedometers are popular research devices for measuring physical activity in real-life settings. Although strategies are used to avoid non-wear, little is known about the effect of non-wear on daily step counts. The purpose of this study was to investigate the effect of non-wear on pedometer estimates of physical activity, by comparing step counts from a traditionally worn pedometer (NL-1000, New Lifestyles Inc, Lee’s Summit, Missouri, USA) to step counts from a permanently-worn motion sensor (activPALTM monitor, PAL Technologies Ltd, Glasgow, Scotland). METHODS Twelve men and 25 women aged ≥ 65 yrs (M = 70 yrs, SD = 5 yrs) were instructed to wear the NL-1000 during all waking hours and were fitted with the activPAL, which was worn continuously. The NL-1000 records and stores step counts over the previous 7 days, and is worn on the waist band above the anterior midline of the thigh. The activPAL stores data for up to 8 days and is attached to the anterior surface of the thigh using a waterproof coating. By checking date recordings, we determined there were 236 overlapping days (i.e. when both monitors were worn). Outliers (steps/day < 1,000 and > 30,000; n = 14, or 3% of all data points) were removed from the analysis, leaving 225 pairs of overlapping data. Mean pedometer step counts were compared to the activPAL via one-way dependent ANOVA. The mean difference was also compared using Cohen’s d to evaluate the effect size. RESULTS Pedometer and activPAL steps were normally distributed (skewness = 0.43 and 0.59, kurtosis = -0.16 and 0.46). The ANOVA showed that mean activPAL steps (M = 8,165, SD = 3,254) were significantly higher than NL-1000 steps (M = 6,236, SD = 2,972); F(1,224) = 246.7, p < .001. Cohen’s d was 0.62, indicating a moderate-to-large effect size. Additionally, the correlation between measures (r = .83) was relatively high, indicating that participants’ relative order was similar regardless of pedometer non-wear. DISCUSSION AND CONCLUSION When worn following standard instructions regarding continuous wear, steps obtained from a waist-worn pedometer appear to grossly underestimate steps taken over a 24-hour period by approximately 2,000 steps, as measured by a permanently-fixed activity monitor. This has potentially profound implications for the use of pedometers in population surveillance and physical activity interventions. Additional strategies may be necessary for either reducing non-wear time or monitoring non-wear time, in order to obtain accurate estimates of 24-hr physical activity.MacMillan, F; Rowe, DA; Grant, PM; Granat, MH; Mutrie, N Are We Missing Steps? A Comparison of Pedometer Counts and 24-Hour Motion Sensor Counts in Older Adults 2nd ICAMPAM 2011. http://www.umass.edu/sphhs/documents/ConferencebookICAMPAM2011.pdf.