Comparison Of International Physical Activity Questionnaire (ipaq) With Inclinometry (activpal) For Measuring Sitting Time

Chastin, SFM; Culhane, B; Dall, P

3rd International Conference on Ambulatory Monitoring of Physical Activity and Movement

INTRODUCTION: Too much time spent sitting has been identified as a public health risk, independent of a lack of physical activity. While objective measures of sitting time and sedentary behaviour are becoming more widely used, self reported measures of sitting time are still the most pragmatic and frequently used solution for population surveillance. The International Physical Activity Questionnaire (IPAQ) is a widely used self reported measure, and includes items assessing sitting time. These items were deemed approximately as valid and reliable as sitting time measured objectively with an Actigraph. However, it is accepted that using the Actigraph as a criterion measure does not provide a true measure of sitting, and it has recently been recognised that inclinometers such as activPAL offer a more valid and accurate objective measure of sitting time. PURPOSE: To compare the accuracy of the IPAQ sitting time item against a robust objective measure of sitting time (activPAL). METHODS:A convenience sample of volunteers (N=80; 25 to 62 years old) were recruited from the general population of Glasgow. They wore an activPAL activity monitor continuously for 7 days. At the end of this period the participants completed the IPAQ sitting items detailing the time spent in sitting during week and weekend days. The activPAL data were processed to identify sitting periods and total sitting time over the same periods for each individual. IPAQ and activPAL data were compared using intraclass correlation coefficients (ICC), Pearson correlation and Bland Altman analysis for sitting time over the total week, week days and weekend periods. RESULTS: Correlation between IPAQ and the criterion objective measure is very low (total week ICC=0.11, week days ICC=0.16, weekend ICC=0.28) and no statistically significant linear correlations were found. The Bland Altman revealed that sitting time was consistently underestimated by IPAQ. This error was systematic across the range of objectively measured sitting time for the total week (mean = 3.39 h/day, CI [0.56 6.21]) and for the weekend (mean = 4.64 h/day, CI[1.24 8.03]). For week days the mean difference was 3.43 h/day (CI [0.62 6.25]), but showed a trend, inversely proportional to the amount of sitting suggesting that the error is relative to the total amount of time spent sitting.CONCLUSION: The sitting items of IPAQ are a poor measure of sitting time in terms of accuracy. They underestimated true sitting time, which suggests that population surveys based on IPAQ might also be underestimating the prevalence of sitting time. However due to the systematic nature of the error it might be possible to develop corrections for the IPAQ items.

NA

Chastin, SFM; Culhane, B; Dall, P Comparison Of International Physical Activity Questionnaire (ipaq) With Inclinometry (activpal) For Measuring Sitting Time 3rd International Conference on Ambulatory Monitoring of Physical Activity and Movement 2013. http://www.umass.edu/sphhs/sites/default/files/ICAMPAM_Slide_Poster_Composite_6.6.pdf.