Exploring the Relationship Between Energy Expenditure Recorded by Indirect Calorimetry and Activity Monitors with Gait Speed

Rafferty D, Dall PM, Stansfield B

2nd International Conference on Ambulatory Monitoring of Physical Activity and Movement, Glasgow, Scotland 24 – 27 May 2011, (p 67)

INTRODUCTION Energy expenditure (EE), as estimated by many accelerometer based activity monitors, is calculated on the basis that the faster the body segment that the monitor is attached to moves the greater the EE. Most validation studies of such devices have explored this relationship over a wide range of walking speeds ranging from slow to fast, and correlated EE across the speed range. This potentially masks the facts that EE for slower gait is less dependent on speed than faster gait, or that pathological gait may be slower for an equivalent EE [1,2]. METHODS Eight healthy volunteers (our aim is to recruit 20) walked around two cones 9.5m apart at five different speeds: Self selected (SS), 60%SS, 80%SS, 120%SS, 140%SS, for a duration of 5 minutes at each speed. For speeds other than SS this was controlled using a bleep at each cone to indicate the participants had achieved the desired pace. Volunteers wore the K4b2 gas analyser, the Actigraph(GX3), a uniaxial ActivPal, and a Senseware Armband (Version5.1). EE was calculated for the 4th minute for all devices at each speed. Correlation coefficients of speed with EE for each device were calculated across all speeds, at SS and above, and at speeds slower than SS. RESULTS The correlations for all speeds and for speeds at or above SS were all strong and highly significant (figure 1). However for the speeds slower than SS the correlation between K4 EE became non significant as did that of the Senseware Armband, whereas the correlations for the Actigraph and the ActivPal with speed remained strong and significant. Figure1 DISCUSSION AND CONCLUSION These results suggest that activity monitors based on accelerometers alone may not account for reduced gait speed when reporting EE. The Senseware Armband in addition to accelerometers has other integrated biosensors, which may explain why, in a similar fashion to the indirect calorimetry, the correlation of EE with speed loses significance at speeds slower than SS. Pathological gait often results in a reduction in gait speed. Previous studies involving people with MS[1] and young stroke survivors[2] have shown that although gait is slowed there is still the same energy demand. This could fail to be reflected if using EE from devices solely based on accelerometers. It is beyond the scope of this work to establish the efficacy of the Senseware Armband in patient populations REFERENCES [1] Paul et al Multiple Sclerosis 2008; 14: 954 961 [2] Platts et al Medicine & Science in Sports & Exercise. 2006; 1041-1046

NA

Rafferty D, Dall PM, Stansfield B Exploring the Relationship Between Energy Expenditure Recorded by Indirect Calorimetry and Activity Monitors with Gait Speed 2nd International Conference on Ambulatory Monitoring of Physical Activity and Movement, Glasgow, Scotland 24 – 27 May 2011, (p 67) 2011. https://www.umass.edu/sphhs/sites/default/files/Conference%20book%20ICAMPAM2011.pdf.