Comparison Of Two Accelerometers For The Measurement Of Energy Expenditure In Females During Walking

Harrington, D; Donnelly, A

13th Annual Congress of the European College of Sport Science

Objective and valid measures of Physical Activity (PA) are important for quantifying free living PA levels in different populations (Rowlands & Eston, 2007). One non-invasive method of estimating PA is collection of data from recording accelerometers, which allow several days of continuous measurement. Data from accelerometers can be used to estimate energy expenditure in activities such as walking. The aim of the study was to compare the effectiveness of two accelerometers, the ActivPAL Professional physical activity logger (PAL Technologies Ltd, Glasgow, Scotland) and the Actigraph accelerometer (LLC, Pensacola, Florida) in predicting Energy Expenditure (EE) during walking. The study was approved by the University of Limerick Research Ethics Committee, and volunteers completed informed consent documents prior to participation. Seventeen females aged 23 (SD 2) yrs walked for 7 minutes at each of 5 speeds (3.2, 4.8, 5.6, 6.4 and 7 km per hour) on a treadmill whilst simultaneously wearing the ActivPAL and the Actigraph accelerometers. Oxygen consumption and other variables were recorded for the last 2 minutes at each walking speed by expired gas analysis. Step counts were recorded every 15 seconds by the accelerometers and also by analysis of video recordings. Additionally, accelerometry counts were sampled by both accelerometers for each 15 second epoch. Step count agreement (r-value) between ActivPAL and Actigraph was 0.954. Correlations between ActivPAL steps and Actigraph steps with manual steps count were 0.988 and 0.953 respectively. When comparing energy expenditure (kilojoules per minute) with the two accelerometer step counts, the agreement was 0.594 and 0.552 for the ActivPAL and Actigraph respectively. Adjusting the energy expenditure for body weight increased the agreement to 0.632 and 0.581 for the ActivPAL and Actigraph respectively. On comparing metabolic equivalent to step count of the two accelerometers, correlations of 0.543 and 0.528 for the ActivPAL and Actigraph respectively were seen. Comparing heart rate at each speed to step count revealed correlations of 0.727 and 0.685 for the ActivPAL and the Actigraph respectively. However, accelerometry counts correlated more closely with EE. Both accelerometers accurately measured step count, though the Actigraph tended to underestimate counts at low speeds. Relatively low correlations between accelerometry and measured EE indicate that accelerometry can at best only approximate EE with the ActivPAL outperforming the Actigraph in all analyses. However, raw acceleration data may provide a better predictor of EE since it is more sensitive to small changes in intensity.

NA

Harrington, D; Donnelly, A Comparison Of Two Accelerometers For The Measurement Of Energy Expenditure In Females During Walking 13th Annual Congress of the European College of Sport Science 2008. NA.