Grant M, Ryan C, Tigbe W, Granat M
Biomechanics of the lower limb in health, disease and rehabilitation. Salford’s 3rd International Conference Salford, UK 5 – 7 September 2005
Introduction: In order to provide appropriate recommendations for health programmes, objective information about activity patterns and the amount of physical activity undertaken in the population is needed. The activPALTM professional (PAL Technologies Ltd) is a relatively new device designed to objectively measure the duration, frequency and intensity of physical activity throughout the day. Currently no validity or reliability data on this device exists in peer-reviewed literature. Aims and objectives: To evaluate the validity and reliability of the activPALTM physical activity monitor as a measure of free-living activity using observational analysis as the criterion measure. Method: A convenience sample of ten adults participated in this laboratory based study. Each participant performed a range of everyday tasks incorporating walking, standing and sitting/lying while wearing three activPALTM monitors on the anterior aspect of the mid thigh. Usually only one activPAL monitor is worn as in Figure 1. Figure 1. The activPAL physical activity monitor in situ. The tasks were randomly assigned and the total time for each participant ranged from 34 47 minutes. Each trial was captured on digital camera and the recordings synchronized with the activPALTM. The recordings, were visually classified by three observers and mean results compared to the activPALTM output. Time spent in the three primary postures of sitting, standing and walking were compared. Reliability was assessed using Interclass Correlation Coefficients (ICC). Validity was assessed by looking at the level of agreement between the activPAL and the video observation. Result: Interobserver reliability (ICC 3,1) was found to be excellent (>0.97) and interdevice reliability (ICC 2,1) was found to be good to excellent (0.78-0.99). The percentage agreement between the activPALTM monitor and observation was analyzed using the Bland and Altman method. The results are presented in table 1. Sitting (%) Upright (%) Standing (%) Walking (%) Mean Difference 0.19 -0.27 -1.4 -2.0 Upper limits of agreement 1.06 0.84 9.1 12.1 Lower limits of agreement -0.68 -1.38 -6.2 -16.1 Table 1: The percentage level of agreement between the activPAL and video observation. The activPAL and video observation were also compared in a second-by-second analysis using the method outlined by Bussmann et al. (1998) [1]. For the latter method percentage agreement was 95.9% with sensitivity and predictive values ranging from 88.1% to 99.6%. Disscussion: The level of agreement between the activPAL activity monitor and video observation was excellent for sitting and upright. The agreement was not as strong for standing and walking, indicated by the wider limits of agreement in table 1. One explanation for this may be that the protocol invovled a high number of short duration walks (1-2s). Such short activities are difficult to classify even for observational analysis which is considered the gold standard method in this study. Overall, the activPAL compares well to other devices which perform similar postural analysis in terms of reliability and validity [2, 3]. Conclusion: The activPALTM activity monitor is a valid and reliable objective measure of free-living physical activity.Grant M, Ryan C, Tigbe W, Granat M Validation of the activPAL activity monitor in measuring free-living physical activity Biomechanics of the lower limb in health, disease and rehabilitation. Salford’s 3rd International Conference Salford, UK 5 – 7 September 2005 2005. NA.