Libertine A, Lyden K, Kozey-Keadle S, Freedson PS
2nd International Conference on Ambulatory Monitoring of Physical Activity and Movement, Glasgow, Scotland 24 – 27 May 2011, (p 58)
INTRODUCTION Measuring steps per day (SPD) is a practical method to evaluate physical activity (PA) in a free-living setting. Several activity monitors are available to measure SPD, however it is not known whether these devices produce similar step counts in a free-living environment. Therefore, the purpose of this study was to compare SPD recorded by three activity monitors including the ActiGraph GT3X, activPAL and Omron HJ-720-ITC. METHODS Free-living PA was monitored for 7 days in twelve moderately active subjects (age= 24.5 + 5.07 years, BMI = 23.5 + 2.09 kg?m-2) using the ActiGraph GT3X, activPAL (AP) and Omron Pedometer (PD). The ActiGraph was initialized two different ways, 1) using the low frequency extension (AGL), and 2) using the normal frequency mode (AGN). Participants wore the PD and two ActiGraph monitors on a belt around their waist and the AP was attached to the mid-thigh. Participants SPD from each monitor were determined at the end of the monitoring period. A linear mixed effects model was used to test for differences in SPD among monitors. RESULTS There were no significant differences in SPD recorded by the AGN and the PD. All other inter-monitor comparisons revealed significant differences in SPD. Mean Absolute Difference (SPD) Lower CI (SPD) Upper CI (SPD) AGL vs. AGN* 6937 5620 8254 AGL vs. AP* 6140 4836 7444 AGL vs. PD* 6711 5685 8138 AGN vs. AP* 765 -1415 -114 AP vs. PD* 765 357 1174 AGN vs. PD 22 -411 454 *Significant difference between monitors DISCUSSION The only monitors that recorded similar SPD were the AGN and the PD. The AGL recorded much higher SPD (mean difference between 6140 and 6937) compared to all other monitors. The low frequency extension (LFE) used by the AGL monitor potentially enables the device to capture low intensity steps (e.g. shuffling) that may be characteristic of free-living activity. However, it is possible the LFE also leads to misclassification of non-ambulatory low intensity acceleration (e.g. artifacts) as steps, which would inflate the mean differences. In contrast, steps accumulated in bouts lasting less than 4 sec are not captured by the filter in the PD. Similarly, the filter in the AP does not capture steps accumulated in bouts lasting less than 10 sec. Thus, researchers should be cautious in comparing SPD across studies using different monitors. Future research should include a criterion measure to determine the validity of each monitor.Libertine A, Lyden K, Kozey-Keadle S, Freedson PS Steps Per Day : A Comparison of Popular Activity Monitors 2nd International Conference on Ambulatory Monitoring of Physical Activity and Movement, Glasgow, Scotland 24 – 27 May 2011, (p 58) 2011. https://www.umass.edu/sphhs/sites/default/files/Conference%20book%20ICAMPAM2011.pdf.