O’Dwyer C, Coote S
16th International WCPT Congress, Amsterdam Netherlands 20 – 23 June 2011. Physiotherapy 97 (S1) : eS18 – eS1415
Purpose: To determine the criterion validity of the Senswear Armband (SWA) and ActivPAL (AP) activity monitors as a measure of physical activity (steps and energy expenditure) in persons with Multiple Sclerosis (PwMS). Relevance: Research has found that PwMS are significantly less physically active than healthy individuals (Motl et al. 2005). The majority of physical activity (PA) research has utilised subjective measurement tools which have notable associated limitations. Accelerometry based activity monitors are thought to provide the optimal objective PA measurement tool. However, no research to date has examined the criterion validity of any such device in PwMS. Participants: 30 subjects with MS and 15 healthy control subjects were recruited through the MS Society and via campus-wide email. Subjects with MS mobilised either independently or with the assistance of one stick (MSA) or with bilateral aids or a walking frame (MSB). Subjects were excluded if they were currently experiencing a worsening of symptoms due to a relapse. Methods: The Oxycon Mobile indirect calorimetry unit was the criterion method of mesuring energy expenditure with the proprietary algorithms used to estimate steps and METs. Subjects were fitted with the AP on the mid-thigh, the SWA over the triceps and a facemask attached to the Oxycon Mobile unit. Subjects performed nine ADL activities as follows: dressing, walking, watching television, washing dishes, reading, stair climbing, writing/typing, dusting and folding laundry. Each activity lasted 10 minutes with the exception of stair-climbing which was 5 minute duration. The entire procedure was video recorded and steps taken were manually counted (criterion method). Analysis: Intra-class correlation coefficients and Bland and Altman analysis was used to determine the level of agreement between methods. The percentage error between methods was also calculated. Results: The SWA demonstrated a smaller percentage error (range 0.94% to -29.39%) across groups for step count than the AP (range -31.93% to -34.5%). The mean difference from manual step count for the SWA was 20 steps for the control group, 397 steps for MSA and 320 steps for MSB, as against 695 steps for the control group, 545 steps and 376 steps for the MSA and MSB groups respectively with the AP. The SWA had ICC’s of 0.5-0.63 compared to 0.1-0.16 for the AP for METs and a notably smaller mean difference also. Conclusions: The SWA is better than the ActivPAL for measuring both steps and energy expenditure during combined upper and lower limb ADL’s when using the proprietary algorithms. The validity of the SWA for step count is negatively affected by gait impairment. The AP is a poor estimate of energy expenditure in PwMS. Implications: Future PA research in MS should use the SWA as these results suggest it is a valid estimate of steps and energy expenditure in PwMS. Future research should incorporate PA as an outcome measure in intervention studies examining the effects of exercise interventions in MS.O’Dwyer C, Coote S Validity Of The Sensewear Armband and activPAL Activity Monitors in Multiple Sclerosis 16th International WCPT Congress, Amsterdam Netherlands 20 – 23 June 2011. Physiotherapy 97 (S1) : eS18 – eS1415 2011. http://linkinghub.elsevier.com/retrieve/pii/S0031940611000691.