Discordance Of Sedentary Time Reporting In Adults With Total Knee Replacement: 2665

DeVivo, Katherine Eileen; Jamieson, Scott; Yang, Chih-Hsiang; Pellegrini, Christine

Medicine & Science in Sports & Exercise

PURPOSE: The purpose of this study was to compare differences and level of agreement between adults self-reported ST and objectively measured ST. METHODS: As part of a sedentary reduction intervention for adults following knee replacement (TKR), participants ST was self-reported (screening item and SIT-Q) and objectively measured (activPAL). The screening item asked hours per day (h/d) that participants spend sitting. The SIT-Q-7d is a self-administered questionnaire that quantifies ST in the last 7 days by assessing behavior across five domains of daily life activities and calculates weekday and weekend SIT-Q scores (h/d). For 7 days, participants wore an activPAL on their thigh, the gold standard for assessing sedentary behavior, to measure ST (h/d). Paired samples t-test compared mean differences in ST between the self-reported measures and activPAL. Interclass correlation coefficient (ICC) measured the extent of agreement between self-reported and objectively measured ST. RESULTS: Participants (n = 40) were 65% female, 85% White, 65.1 ± 9.0 yrs, 34.1 ± 6.9 kg/m2 BMI. Self-reported ST via screener (9.0 ± 2.1 h/d) and ST via the SIT-Q weekend (10.3 ± 3.4 h/d) were significantly lower (p < 0.001 and p = 0.009, respectively) than activPAL ST (12.1 ± 2.2 h/d). There was no difference (p = 0.202) in ST between the SIT-Q weekday (11.3 ± 3.6 h/d) compared to activPAL. ICC between the activPAL and screener was 0.301, 95% CI -0.012 - 0.560, between the activPAL and SIT-Q weekday was 0.130, 95% CI -0.189 - 0.424, and between the activPAL and SIT-Q weekend was -0.001, 95% CI -0.312 - 0.311. CONCLUSIONS: The level of agreement in ST was low between the self-reported and objective measures in adults after TKR. The one-item screener question resulted in significantly lower estimates of ST than that measured by the activPAL. Caution is warranted on future use of this one item to obtain an accurate measure of ST in this population. If objective measures are not available, the SIT-Q would provide a closer estimate of ST.

10.1249/01.mss.0000988200.60135.f2

DeVivo, Katherine Eileen; Jamieson, Scott; Yang, Chih-Hsiang; Pellegrini, Christine Discordance Of Sedentary Time Reporting In Adults With Total Knee Replacement: 2665 Medicine & Science in Sports & Exercise 2023. https://journals.lww.com/10.1249/01.mss.0000988200.60135.f2.