Kim, Y; Welk, GJ
ACSM Annual Meeting 2014
Objective monitoring tools have been widely used in estimating energy expenditure (EE). However, little is known about the relative validity of different activity monitors to estimate the energy cost of different intensities of physical activity (PA). PURPOSE: The purpose of this study was to examine relative validity of the Core Armband (CA), activPAL (AP) and Actigraph (AG) for estimating EE of sedentary, light PA (LPA), moderate PA (MPA) and vigorous PA (VPA) compared to measured values from a portable indirect calorimetry system (Oxycon Mobile; OM) in adults. METHODS: A total of 37 adults (18 – 40 yrs old; 24% male) each completed a battery of 15 activities over an 89 minute time period while wearing the CA, AP and AG and being monitored with the OM system. The protocol included various activities designed to capture sedentary tasks as well as LPA, MPA, and VPA – each was performed for 5 minutes with a 1 minute rest period. Equivalence testing and mean absolute percent error (MAPE) were used to evaluate the validity of the 3 monitors for estimating the EE cost of activities classified as Sedentary (1-1.5 MET), LPA (1.5-3.0 MET), MPA (3-6 MET) and VPA (6+ MET) by the OM system. RESULTS: The 90% confidence interval (CI) for estimated METs from the CA (3.71- 3.90) fell within the equivalence zone (EZ) established from the OM data (3.22-3.94). However, the CI values demonstrated consistent underestimation for the AP (2.47- 2.66), AG with vertical axis (3.09-3.68) and AG with vector magnitude (2.82-3.01). None of the monitors produced accurate estimates of EE for the sedentary and light activities based on examination of separate EZ values for these intensities. The CA produced equivalent estimates for MPA (90%CI =3.94 – 4.37) and VPA (90%CI = 9.24 – 9.66) relative to the EZ ranges from the OM (MPA: 3.90 – 4.77; VPA: 8.15 – 9.96). The AP produced the smallest MAPE values for sedentary (22%) and LPA (28%) compared to the other monitors (sedentary: ranges from 37% to 113%; LPA: ranges from 54% to 59%) but the CA had the smallest MAPEs for MPA (20%) and VPA (14%) compared to the other methods (MPA: ranges from 24% to 30%; VPA: ranges from 21% to 48%). CONCLUSION: CA outperformed the other monitors in estimating EE, particularly for moderate and vigorous intensity. However, the AP yielded the smallest amount of errors for sedentary and light intensity activity.Kim, Y; Welk, GJ Accuracy Of Activity Monitors For Estimating The Energy Expenditure Of Different Intensity Activities ACSM Annual Meeting 2014 2014. http://acsmannualmeeting.org/educational-highlights/final-program-and-abstracts-2014/.