Validity and user friendliness of three activity monitors

Berendsen, BAJ; Annegarn, J; Hendriks, MRC; Schaper, NC; Willems, P; Plasqui, G; Meijer, K; Savelberg, HHCM

2011 ICAMPAM

INTRODUCTION Health is associated with the amount of daily physical activity. The required amount, frequency and intensity of physical activity still is a matter of debate. Accelerometry can be used to assess human physical activity objectively. In measuring average daily activity it is important to discriminate between standing and sedentary time, because of the increased energy use associated with standing [1]. Recently, it has been suggested that the patterns of sedentary behaviour are strong predictors of future health outcome [2]. A validated and easy to use activity monitor is needed to investigate the relationship between sedentary and standing time and health. Therefore the aim is to compare the validity and user-friendliness of three commercially available activity monitors. METHODS User friendliness was evaluated in 14 participants who wore the accelerometers for at least 45 minutes up to 6 days with questions regarding wearing comfort and preference. Five participants performed a standardized protocol that consisted of sedentary (sitting and lying), standing and walking on the treadmill. Subjects wore three activity monitors simultaneously: 1) CAM (Maastricht Instruments) 2) ActiGraphGT3X and 3) ActivPAL3. The CAM and ActiGraphGT3X were worn in an elastic belt around the thigh and trunk respectively. The ActivPAL3 was taped to the skin at the thigh. Validity of the monitors is expressed as mean±SD percentage of correctly classified seconds. Correlations between accelerometer intensity and walking speed on the treadmill were assessed to determine how accurate monitors reflected subject’s movement intensity. RESULTS Sedentary and standing time was correctly classified in 99.7±0.5% and 96.0±5.5% of CAM-data; in 36.3±20.1% and 90.0±10.6% of ActiGraphGT3X-data; and in 100.0±0.0% and 100.0±0.0% of ActivPAL3-data. Correlations between the different intensity measures of the accelerometers and the walking speed on the treadmill were high (CAM: 0.979; ActiGraphGT3X: 0.910; ActivPAL3: 0.897 (all p=0.000)). Eight participants preferred the ActiGraphGT3X and six participants preferred the ActivPAL. In four participants the CAM resulted in an adverse reaction (skin irritation).

NA

Berendsen, BAJ; Annegarn, J; Hendriks, MRC; Schaper, NC; Willems, P; Plasqui, G; Meijer, K; Savelberg, HHCM Validity and user friendliness of three activity monitors 2011 ICAMPAM 2011. http://www.umass.edu/sphhs/documents/ConferencebookICAMPAM2011.pdf.