Practical Utility and Reliability of the activPAL Monitor for Measuring Posture in Free-Living Pre-School Children

McGowan, A; Dall, PM; Granat, MH; Young, D; Paton, JY; Reilly, JJ

2nd ICAMPAM

INTRODUCTION Behavioural components of Non-exercise activity Thermogenesis (NEAT), notably posture (time spent sitting versus standing), may be important to the development of childhood obesity. However, there is currently no evidence on the practical utility and reliability of objective methods of quantifying posture in free-living young children. The present study therefore aimed to test the practical utility and reliability of the activPAL monitor for measurement of posture (sitting time) in free-living pre-school children. METHODS A convenience sample of 20 pre-school children (age range 3.7-4.9y) was asked to wear the activPAL monitor for 24 hours a day, for 7 consecutive days. Practical utility was assessed via the number of missing/invalid data points and through questionnaire (10 questions) and parent/guardian report. Reliability was assessed by between day comparisons and study length analysis. Pair-wise comparisons by general linear model ANOVA were carried out to test for any significant differences between days. Analysis of study length was by two methods: between-day Intraclass Correlation Coefficients (ICC) and a clinical reliability analysis from 95% confidence interval (CI) ranges. POSTER Abstract s P 2 – 0 1 — P 2 – 8 8 98 RESULTS Only 6.1% of data points were missing/invalid over the study period (an average of 10.1h/child over the week). Five of the 200 questionnaire responses indicated practical utility problems- these related to length of study- 7 days and 24hours per day- and comfort of the monitor. No significant difference between any of the days was observed by pair-wise comparison (p=0.707). An ICC of ≥0.8 was defined as reliable and this level was achieved after 5 days of monitoring (95% CI: 0.80-0.99). The clinically reliable CI range was defined as 2.5 hours as this represents a clinically significant difference in sitting time. A clinically reliable CI range was achieved at a mean length of 5 days monitoring (95% CI: 4.3-5.6). DISCUSSION AND CONCLUSION This study suggests that the practical utility of the activPAL is high in free-living pre-school children, and that young children will wear the monitor overnight. Reliability for measurement of sitting time is also high so long as at least 4- 5 days are monitored.

NA

McGowan, A; Dall, PM; Granat, MH; Young, D; Paton, JY; Reilly, JJ Practical Utility and Reliability of the activPAL Monitor for Measuring Posture in Free-Living Pre-School Children 2nd ICAMPAM 2011. http://www.umass.edu/sphhs/documents/ConferencebookICAMPAM2011.pdf.