Accuracy Of Inclinometer Functions Of The Activpal And Actigraph GT3X+: A Focus On Physical Inactivity

Peters, BP; Kim, Y; Welk, G

ACSM Annual Meeting 2014

As objective measurement tools, accelerometry-based monitors have been broadly used in assessing physical activity in adults. Recently, an inclinometer has been incorporated into various types of activity monitors, and utilized in numerous studies to estimate time spent sitting, standing and walking. However, little is known about its accuracy for adults. PURPOSE: The purpose of the study is to examine the accuracy of inclinometer functions from the ActivPal and Actigraph GT3X+ (worn on the waist and wrist) used to assess time spent sitting, standing and walking. METHODS: A total of 37 adults (age: 18-40 yrs; male: 28) wore three activity monitors (ActivPal, GT3X+ waist, and GT3X+ wrist) while completing 15 different types of activities (8 active and 7 sedentary). The 15 activities were classified into 3 activity categories (sitting, standing, and walking) by direct observation. Minutes estimated from the inclinometers of the three monitors were directly compared to those from direct observation (criterion method) using equivalence testing, effect sizes (Cohen’s D) and mean absolute percent error (MAPE) values. RESULTS: Equivalence testing (90% confidence interval) revealed that none of the devices fell within the defined equivalence range relative to direct observation. The effect sizes with the ActivPAL were small for sitting/lying (0.06), moderate for standing (0.58) and large for walking (0.94). The waist worn GT3X+ yielded a small effect size for estimates of sitting time (0.23) but a large effect size for standing (2.96). The wrist worn GT3X+ produced large differences in estimated sitting time (2.47) and standing (3.01). The MAPEs were substantially smaller from the ActivPal (sitting/laying: 3.1%, standing: 18.23%, and walking: 18.77%) compared with the respective values from the GT3X+ waist (sitting/laying: 10.36% and standing: 226.42%) and GT3X+ wrist (sitting/laying: 83.73% and standing: 128.59%). CONCLUSIONS: The inclinometer functions used in the ActivPal to detect postures were more accurate than those in waist- and wrist-worn Actigraph GT3X+ for estimating time spent sitting, standing and walking. Future research should take this into consideration when interested in classifying activities into sitting, standing and walking.

NA

Peters, BP; Kim, Y; Welk, G Accuracy Of Inclinometer Functions Of The Activpal And Actigraph GT3X+: A Focus On Physical Inactivity ACSM Annual Meeting 2014 2014. http://acsmannualmeeting.org/educational-highlights/final-program-and-abstracts-2014/.