Rowlands, AV; Hurst, TL; Olds, TS; Eston, RG; Gomersall, SJ; Langford, J
3rd International Conference on Ambulatory Monitoring of Physical Activity and Movement
BACKGROUND: There is a need for an unobtrusive, objective method that enables the assessment of sedentary behaviour, physical activity and sleep concurrently in free-living individuals. PURPOSE: The aims of the present study were: a) to determine whether a wrist worn accelerometer can provide valid measures of sedentary time, activity and sleep and b) to explore a novel method for the analysis, identification and visual presentation of sedentary behaviours, the Sedentary Sphere. METHODS: Thirteen adults (age (mean±SD) 34.5±13.2 y) wore a GENEActiv on their wrist and an ActivPAL on their thigh for 24 h. The next day they completed the Multimedia Activity Recall for Children & Adults (MARCA), a computerised use of time instrument. Posture was determined from the GENEActiv and ActivPAL data. Time classified as sleep, sedentary, and moderate-to-vigorous activity (MVPA) was determined from the GENEActiv and the MARCA. GENEActiv data were plotted on the Sedentary Sphere. RESULTS: Sitting time, determined by the GENEActiv (995±128 min), correlated positively with and did not differ significantly from ActivPAL sitting time (1015±99 min), (r = 0.85, p < 0.001). Intra-individual classification agreement across 15 s epochs was 83.9±7.6% (mean kappa = 0.63 ± 0.29). Time classified as sleep and MVPA by the GENEActiv correlated with the corresponding time reported in the MARCA (r=0.71, r=0.70, p < 0.05, respectively). Intra-individual sleep classification agreement between the GENEActiv and MARCA for 5 min periods was 89.8±5.5% (mean kappa = 0.77±0.42). GENEActiv acceleration data were plotted in 3 dimensional space. When sedentary, gravity provided the primary signal allowing wrist elevation (latitude) and rotation (longitude) to be determined. Periods of consecutive points formed distinct clusters which could be differentiated by their position and distribution. These clusters corresponded to specific behaviours with the sedentary behaviours distributed on the surface of a sphere of radius 1g determined by gravity within the signal. Where behaviours included significant levels of acceleration (i.e. they were active and non-sedentary) the clusters were differentiated by points that departed substantially from the surface of the sphere. CONCLUSION: The wrist-worn GENEActiv is an unobtrusive device that can simultaneously assess physical activity, sedentary behaviour and sleep. Concurrent validity with accepted measures of each outcome is good. The Sedentary Sphere can be used to classify sedentary behaviours; location on the surface of the sphere is indicative of posture and movement away from the surface represents the amount of energy of a movement.Rowlands, AV; Hurst, TL; Olds, TS; Eston, RG; Gomersall, SJ; Langford, J Assessment Of Sedentary Behaviours, Activity And Sleep With A Wrist-worn Accelerometer; Introducing The Sedentary Sphere 3rd International Conference on Ambulatory Monitoring of Physical Activity and Movement 2013. http://www.umass.edu/sphhs/sites/default/files/ICAMPAM_Slide_Poster_Composite_6.6.pdf.