Reliability And Validity Of Subjective And Objective Instruments For Measuring Sedentary Behaviour In Older Adults

Farias, NA; Brown, WJ; Peeters, G

3rd International Conference on Ambulatory Monitoring of Physical Activity and Movement

INTRODUCTION: Objective measurement has strengths in terms of validity when compared with self-report, but self-report is more practical for measuring sedentary behaviour (SB) in large-scale studies. Self-report can also provide contextual information about SB and use of time, which are useful when trying to interpret behaviours. However, little is known about the validity and reliability of objective and subjective measurement of sedentary behaviour in older adults. PURPOSE: To assess the reliability and validity of three instruments for measuring SB in older adults. METHODS: 41 community-dwelling older adults (14/27 male/female, 74.5±7.6 years) were visited twice. ActivPAL3TM (AP) and ActiGraph GT3X+ (AG) were worn during 7 consecutive days. A vector magnitude cut-point of <70 counts/15 seconds was applied for defining AG-measured SB. At the end of follow-up, participants completed (1) a single question (SQ) for sitting time on a usual weekday, weekend day and the last day of monitoring time, and (2) a computer-delivered 24-hour recall (24R) for the last two days of monitoring time. To assess reliability, the SQ and 24R were repeated at the end of the second visit and intraclass correlation (ICC) and standard error of measurement (SEM) were calculated. Validity for the three instruments was examined with Pearson’s correlation and Bland Altman plots with AP as the reference standard. RESULTS: For the SQ on an average day, weekday, weekend day and the last day, the ICC ranged from 0.64 to 0.79, with SEM ranging from 1.03 to 1.42 hr/day. ICC for 24R was 0.89 for the last monitoring day and 0.72 for the second last day with SEM of 0.47 and 1.18 hr/day, respectively. The SQ showed poor correlation with AP (r= 0.093 to 0.333), with a mean difference of -3.53 hr/day (SD=2.33). In contrast, 24R showed moderate correlation with AP for both the last day (r=0.437, p=0.037), and the second last (r=0.620, p=0.008), with mean differences of 1.47 (SD 2.51) hr/day (last monitoring day) and 0.82 (SD 2.22) (second last day). Correlation was strong between AG and AP (0.81, p<0.001), the mean difference was -0.013 hr/day (SD 0.16), however, the limits of agreement were wide: -2.00 to 1.97 hr/day. CONCLUSION: When using self-report instruments the 24R is more valid for measuring time spent in SB in older adults than the SQ, which considerably underestimates time spent in SB in older people. AG with a vector magnitude <70 counts/15 seconds is a valid method for measuring SB in populations, but individual variation was high. Additional analyses will be done to examine whether pattern recognition improves the validity of AG measurement in older adults.

NA

Farias, NA; Brown, WJ; Peeters, G Reliability And Validity Of Subjective And Objective Instruments For Measuring Sedentary Behaviour In Older Adults 3rd International Conference on Ambulatory Monitoring of Physical Activity and Movement 2013. http://www.umass.edu/sphhs/sites/default/files/ICAMPAM_Slide_Poster_Composite_6.6.pdf.