Tang, KT; Stansfield, BW; Simpson, D; Maxwell, D; Spence, WD
1st International Conference on Ambulatory Monitoring of Physical Activity and Movement
INTRODUCTION Observations and gait analysis may be carried out in a laboratory environment to determine gait quality [1];and questionnaires may be used to find amputees’ daily activity levels. However, information obtained from questionnaires could be subjective and therefore daily activity monitoring with a worn device would be preferable with elimination of recall bias [2]. Two devices based on the activPAL™ (PAL Technologies Ltd, Glasgow, UK), were designed to monitor trans-tibial amputees’ prosthetic wearing times and activity levels in a free-living environment. The aim of this study was to evaluate the two devices, the pressure monitor and force monitor and to develop an algorithm, which would automatically detect static (with and without prosthesis) and dynamic events with associated step counts. METHODS For the first study 8 subjects, aged 47-71, with mature unilateral trans-tibial amputations were included. The pressure monitor was attached to the suction valve of the socket to record socket pressure. For the second study 5 unilateral trans-tibial amputees, aged 47-65 years, participated. The force monitor was designed with a force sensitive resistor (FSR) (Flexiforce, Tekscan, USA) used as the sensing element placed at the stump/socket interface. In both studies, the subjects were asked to don their prosthesis and performed activities such as sitting, standing, walking, stairs climbing and sitting without the prosthesis, whilst being video recorded. An algorithm was written using Matlab (Mathworks Ltd.) to analyze the signals automatically to allow posture classification and step count. RESULTS Figure 1 shows an example of the pressure profile recorded using the pressure monitor for one of the amputees. Certain features of the pressure profiles were consistent across all of the subjects. A signal analysis code was implemented and the following results achieved: 90.8%, 92.3%, 91.6% and 95.6% accuracy for static events without prosthesis (doffed state), static events with prosthesis (sit or stand), dynamic events and step counts respectively. Force data also showed repeatable patterns. Threshold levels for upright and non-upright activities could be distinguished in each subject and cyclical signals could be identified within the upright events. When the prosthesis was not being worn, zero interface pressure was recorded. A signal analysis code was implemented and the following results were found: 95.0%, 92.8%, 90.1%, 98.7, 94.3% for the accuracy of doffed state, sitting, standing, walking and step counts respectively. DISCUSSION Both suction socket pressures (socket pressure measurement) and interface pressures (force monitor) contained repeatable signal components that could be interpreted as activity. This allowed the automatic detection of static and dynamic events. The signals were reproducible across all subjects. The interface pressure measurement using the force monitor allowed more complete determination of posture. CONCLUSIONS This study demonstrated that both the interface and socket pressures could be used to reliably quantify static and dynamic events and step detection for trans-tibial amputees using suction sockets.Tang, KT; Stansfield, BW; Simpson, D; Maxwell, D; Spence, WD Monitoring Of Daily Activity Levels And Prosthetic Wearing Times In Transtibial Amputees Using Suction Sockets 1st International Conference on Ambulatory Monitoring of Physical Activity and Movement 2008. http://www.umass.edu/sphhs/documents/ConferencebookICAMPAM2008.pdf.