Validation of a novel pocket-based device to measure and provide feedback on physical activity and sedentary behaviour

Gill J, Hawari N, Maxwell D

ISBNPA 2015: International Society of Behavioral Nutrition and Physical Activity, Edinburgh, UK 3 – 6 June 2015 (P1.187, p 424)

Purpose: Time spent sitting is a risk factor for a range of cardiometabolic diseases independent of time spent in physical activity. Thus, interventions to reduce sitting are likely to reduce cardiometabolic disease risk. The most effective intervention tool for increasing physical activity is the pedometer, which enables individuals to self-monitor their physical activity level, set physical activity targets and provide real-time feedback of progress towards their goal. However no device equivalent to the pedometer is currently available for the self-monitoring of sitting behaviour, so development of a new device is required to address this need. We are developing a novel pocket-based accelerometer, called the sitFIT, which measures both sitting time and physical activity, and has a screen to provide real-time feedback on both sitting behaviour and number of steps taken. The purpose of the present study is to validate the sitFIT device for the measurement of sitting behaviour and physical activity. Methods: The validation was conducted in two parts. In part 1, 40 participants wore accelerometers in left and right pockets, while sitting, standing and walking at speeds from 1 to 8 km/h on a treadmill. Expired air was collected throughout to measure oxygen uptake (and thus energy expenditure), and participants were videoed to enable direct observation of stepping rate. Vector magnitude accelerations were measured at each intensity and related to walking speed and oxygen uptake. In part 2, 8 participants wore prototype sitFIT devices in their left and right pockets, and activPAL accelerometers on both thighs, for up to 7 days. A novel algorithm to determine sitting, standing and stepping for pocket placement will be developed, and agreement between the pocket and (gold-standard) thigh position for activity behaviours in the free-living setting will be compared. Results: Initial analysis of the treadmill data shows very strong relationships between vector magnitude accelerations and walking speed/oxygen uptake (r2 = >0.96). Conclusions: Our preliminary data confirm the viability of the pocket placement for measurement of walking speed and energy expenditure of stepping activities. Further analysis will determine the viability of the pocket position for the measurement of time spent sitting.

NA

Gill J, Hawari N, Maxwell D Validation of a novel pocket-based device to measure and provide feedback on physical activity and sedentary behaviour ISBNPA 2015: International Society of Behavioral Nutrition and Physical Activity, Edinburgh, UK 3 – 6 June 2015 (P1.187, p 424) 2015. https://www.isbnpa.org/files/annual_meetings/2015/06/10/16/attachments/557869344fefe.pdf.