Validity of Activity Monitors for Measuring Steps in an Inpatient Rehabilitation Population

Treacy D, Hassett L, Schurr K, Chagpar S, Sherrington C

9th World Congress on Active Ageing, Melbourne 28 June – 1 July 2016; J Aging Phys Activ 2016 24 (S) : S104

Introduction: While studies have shown activity monitors to be accurate in measuring step counts within healthy populations, several studies have identified the need for further validation studies to be performed in slower walking populations such as expected within an inpatient rehabilitation setting. Our research questions were: (1) What is the criterion validity of various activity monitors in measuring step counts in an in-patient rehabilitation population? (2) What gait parameters influence the accuracy of these activity monitors? Methods: 166 rehabilitation inpatients, with an average (SD, range) age of 80 (11, 26 98) were recruited from the Bankstown General Rehabilitation Unit and Stroke Unit, Australia. Each participant wore 16 activity monitors (six different models) simultaneously while completing a six-minute walk test (6MWT). Garmin vivofit and the Fitbit Charge were worn on both wrists; standard piezoelectric pedometers (G-Sensor Accelerometer) were worn on each hip; Fitbit Ones were worn on both hips and also on both ankles; ActiGraph GT3X+ accelerometers were worn on both hips; ActivPALs were worn on both thighs; StepWatch Activity Monitors were worn on both ankles. A manual step count of the number of steps taken was recorded during the 6MWT. Gait parameters were assessed using the GAITRite portable gait analysis system. Results: The StepWatch (ICC2, 1 = 0.98, 95% CI 0.98 0.99), Fitbit One on the ankle (ICC2,1 = 0.92, 95% CI 0.77 0.96), and the ActivPAL (ICC2,1 = 0.78, 95% CI 0.23 0.91) all showed excellent agreement with the manual step count. All other devices showed poor agreement with the manual step count. Percentage agreement was closest for StepWatch steps compared to the manual count (mean 98%, SD 12%). All devices were less accurate at slower gait speeds and shorter strides, but the StepWatch and the Fitbit One used on the ankle maintained the best accuracy overall. Conclusion: The StepWatch showed the highest accuracy and closest agreement with the manual count of all the devices assessed in this study. The Fitbit One used on the ankle showed high agreement with the manual count and provides immediate feedback to the patient.

NA

Treacy D, Hassett L, Schurr K, Chagpar S, Sherrington C Validity of Activity Monitors for Measuring Steps in an Inpatient Rehabilitation Population 9th World Congress on Active Ageing, Melbourne 28 June – 1 July 2016; J Aging Phys Activ 2016 24 (S) : S104 2016. http://wcaa2016.com.au/.