Ellingson L, Schwabacher I, Meyer J, Kim Y, Welk G, Cook D
Society of Behavioral Medicine Annual Meeting, Washington 30 March – 2 April 2016; Ann Behav Med (2016) 50 (Suppl 1) : S76
Accurate assessment of both physical activity and sedentary behaviors is crucial to understand the health consequences of movement patterns as well as to track changes over time and in response to interventions. PURPOSE: To examine the criterion validity of two machine-learning methods for processing activity monitor data in relation to a portable metabolic analyzer (OM; Oxycon Mobile) and direct observation. METHODS: Fortynine adults (ages 18-40) each performed 15 activities in 5-minute bouts ranging from sedentary to vigorous intensity in a laboratory setting while wearing the ActiGraph (AG) and activPAL (AP) monitors and the OM. Estimates of energy expenditure (EE) and intensity categorization were obtained from the OM and the Compendium of Physical Activity and compared with those obtained from the AG processed with Lyden s Sojourns 3-axis method (SOJ) and our new Sojourns Including Posture (SIP) method integrating output fromthe AG and AP. Categorization accuracy and estimates of EE were compared to criterion measures (Compendium, OM) using confusion matrices, comparisons of log transformed mean absolute error (MAE), and Bland Altman plots. RESULTS: Using the Compendium as the criterion, the SIP method had an overall percent agreement of 0.79 [95% CI 0.75, 0.82] compared to SOJ at 0.56 [95% CI 0.52, 0.59]. The sensitivity of the SOJ method for light intensity activity was particularly low at 0.17, compared to SIP at 0.73, with SOJ misclassifying light intensity as sedentary 57% of the time. Compared to OM, estimates of EE from SIP were superior to SOJ with smaller MAE for light (0.21 vs. 0.27), moderate (0.33 vs. 0.42) and vigorous (0.16 vs. 0.36) intensities. Bland Altman plots showed good agreement between OM and both SIP and SOJ, with small biases for light and vigorous intensities. CONCLUSIONS: Both SOJ and SIP are comparable to criterion measures. However, the SIP method was superior to SOJ, particularly for differentiating between light intensity and sedentary activities. Thus, SIP is recommended for research in which accuracy of measurement across the full range of activity intensities is paramount.Ellingson L, Schwabacher I, Meyer J, Kim Y, Welk G, Cook D Integration of data from ActiGraph and activPAL monitors: criterion validity of the SIP Method Society of Behavioral Medicine Annual Meeting, Washington 30 March – 2 April 2016; Ann Behav Med (2016) 50 (Suppl 1) : S76 2016. http://link.springer.com/10.1007/s12160-015-9766-4.