Maclean, D; Grant, M; Granat, M; Dall, P
4th International Congress on Physical Activity and Public Health Australian Conference of Science and Medicine in Sport National Sports Injury Prevention Conference
Introduction: Many body-worn accelerometers provide an accurate measure for number of steps during walking, however the start and end point of those steps is often not reported, meaning the individual step duration cannot be determined. There has been recent interest in using cadence for measurement of walking intensity in large datasets. However, calculating an accurate value for cadence requires that the duration of walking is known as well as the number of steps taken and when a bout starts and ends. This study aimed to develop and validate an algorithm to identify the start and end points of a stride from the acceleration output of a body-worn sensor. Methods: The algorithm was developed on acceleration data collected from 25 healthy adults (15 females; mean±SD age 40±13years), walking for 0.2–1.5km at slow, normal, fast and variable self-selected speeds. Participants wore an activity monitor (activPAL™), and the 10Hz raw acceleration signal was examined to manually identify the occurrence of consistent points in the stride (approximating to heel strike). A separate validation data set was collected from 20 participants (12 females; 34.5±6.9years) walking for 1.5km at slow, normal and fast self-selected speeds. The number of steps identified (number of strides*2) for the validation data was compared to observation (criterion measure). Accuracy of the algorithm in identifying the start and end points of each stride was compared to manual identification. Results: The step count from observation (mean±SD) was 653±40 (slow), 608±44 (normal) and 579±41 (fast). The developed algorithms determined a step count of 656±41 (slow), 612±44 (normal) and 580±43 (fast). The percentage error between observational data and the algorithm output was 0.39±0.67 (slow), 0.45±0.84 (normal) and 0.09±1.17 (fast). This was comparable to the step count provided by proprietary activPAL™ algorithms. The accuracy of the algorithm in identifying the start and end of a stride for the validation data was 99.4%, with 0.4% overcount (algorithm identified non-existent points). Discussion: The algorithm developed, identified the start and end points of a stride with >99% accuracy, and was as accurate as proprietary algorithms in correctly identifying number of steps. The algorithm could be used to identify the start and end of a stride in a consistent manner allowing a precise measure of cadence or additional assessment of stride characteristics. In addition, accurate determination of strides would be useful for determining step characteristics to separate types of walking (e.g. stair climbing).Maclean, D; Grant, M; Granat, M; Dall, P Using a body-worm accelerometer to identify the start and end points of a stride during walking 4th International Congress on Physical Activity and Public Health Australian Conference of Science and Medicine in Sport National Sports Injury Prevention Conference 2012. http://sma.org.au/wp-content/uploads/2012/04/1389-SMA_ConferenceBOA_WEB_FA_150ppi.pdf.