Cox CP, Rafferty D, Dall PM
2nd International Conference on Ambulatory Monitoring of Physical Activity and Movement, Glasgow, Scotland 24 – 27 May 2011, (p 122)
INTRODUCTION Accelerometer-based activity monitors, which report their outcome as counts accumulated over a fixed time-period (epoch), are currently the most common form of measuring objective physical activity. More recently, accelerometer-based activity monitors which report outcome as time spent in postural and activity categories, have been used. These monitors report duration to a much finer resolution. The effect of epoch length on the reported duration of activity when comparing these two classes of activity monitors has not been explored. METHODS Eleven healthy adults (5 male, age 29 8 years, BMI 23.4 2.9kg.m-2) wore two activity monitors (Actigraph and activPAL) simultaneously during a short controlled series of activities [five short periods of walking (15s; 30s; 30s; 45; 60s) with periods of standing (15s-45s) between], and spending an hour away from the university campus as they wished (n=9). The Actigraph monitor (GT3X) was set to collect data in 1 minute epochs, and counts were categorised as not walking (<=760) or walking (>760). The activPAL activity monitor presents data as one of three postural categories (sit/lie; stand; walk) in durations to the nearest 0.1s. For the controlled tests, total duration of walking was compared to the known walking content of the test (1-sample t-test). For both tests, total duration of walking was compared between monitors (paired t-test). RESULTS In the controlled tests, the ActivPAL always recorded 5 separate walking events. Total duration of walking events 177 5s was not significantly different to the known value 180s (p=0.051), and no single walking event was more than 5s different from the values specified in the protocol. For the Actigraph the number of walking periods identified were fewer than those undertaken (1-4). The total duration of walking was 284 61s, which was significantly higher than the known value (p<0.001), and the activPAL (p<0.001). Outdoors, participants spent the majority of their time walking (38 10 minutes). The mean absolute difference in walking duration between the Actigraph and the activPAL was 4 1 minutes. The difference in duration between monitors was not significantm(p=0.6), but could represent up to a 24% difference on an individual basis. DISCUSSION AND CONCLUSION Despite the relatively low levels of walking recorded during the study, there were differences in the duration of walking recorded between the monitors of up to 24%. The difference between monitors was not statistically significant, but has the potential to be a threat to direct comparisons in the duration of walking over longer periods of monitoring.Cox CP, Rafferty D, Dall PM Effect of Epoch Length on the Total Reported Duration of Walking 2nd International Conference on Ambulatory Monitoring of Physical Activity and Movement, Glasgow, Scotland 24 – 27 May 2011, (p 122) 2011. https://www.umass.edu/sphhs/sites/default/files/Conference%20book%20ICAMPAM2011.pdf.