Karason GG
American Academy of Orthotists and Prosthetists Annual Meeting, Orlando, Florida, USA March 2005, P15
It is imperative to measure the outcome of any orthotic or prosthetic treatment (1). This creates a foundation for monitoring progress and continuous improvement which should be the goal of all health professionals. The O&P profession needs to provide evidence of results from the treatment provided; it has become necessary to be able to back up any decision with documented data. The amount and mode of locomotion is a good indicator of a person’s general well-being, and this is obviously especially important for a lower limb amputee. The evaluation of amputee activity is currently most often done by subjective assessment of the clinician. Existing tools to aid in this assessment are mainly different types of questionnaires, as well as various methods or tests to measure the performance of the amputee. The questionnaires rely on the ability of the person to evaluate and report on own activities. The performance tests are normally conducted in the workshop and focus on measuring the ability of the amputee to perform certain tasks at that point in time. These tests do therefore not represent the actual activity of the amputee in every day live, but rather their ability to perform under the supervision of the clinician. These types of measurements do not always yield accurate and correct results (2-4). Several devices have been developed in recent years to address the need for an objective and accurate measurement of activity. A short description of some of these devices follows. Although this list should not be considered to be a complete list of all available devices, it should serve as an overview of what has been developed and used in the O&P industry. One of the latest developments is the Ossur Patient Activity Monitor1 (PAM). This device is based on a set of miniature accelerometers contained in a single housing with battery and LCD display. This is a small device that can be attached to the prostheses and collects information on the activities of the wearer for up to one week. The device uses continuous measurements of acceleration to detect steps taken with the prostheses, and is based on patented SpeedMax2 technology. By continuously measuring the position of the device it is possible to reconstruct the path of the prosthesis through space, and therefore collect relevant information for each and every step taken. As the length and speed of each step is measured it is not necessary to calibrate the device for each amputee, and the unit automatically takes into account varying step length, speed etc (5). The unit collects, calculates and displays the results on the incorporated LCD display, eliminating the need to post process the information on a PC, hence making it possible to get immediate results from measurement. Figure 1 shows the Ossur PAM attached to a prosthetic limb. What makes this device unique is the fact that it measures and calculates the speed and distance of each step, but this makes it possible to retrieve a range of variables and information that has so far not been available without the use of advanced and expensive gait laboratories. The unit is attached with a simple Velcro strap to the ankle of the person being measured. This makes it possible to fasten the unit directly to the prosthesis and thereby eliminates the need for the user to attach the unit each morning. A watertight and shockproof housing assures that the unit withstands use in the real lifesituation in the workshop, and a simple and straight-forward measurement procedure allows for the use of PAM as part of every day work routine rather than for research purposes only. After collecting measurements for up to one week the following variables are calculated and displayed: PAM Index Total time spent in Active mode [min/day] Total time spent in Locomotion mode [min/day] Total time spent in Idle mode [min/day] Total number of steps Total distance traveled [m] Mean Step Length [m] Mean speed [m/s] Mean cadence [steps/min] Impact [m/s2] Maximum sustained walking speed [m/s] The PAM Index is a weighed average of ten sub-indexes. This is a unitless number ranging from 0 to 100 which allows simple comparison of patients or measurements. A second device that can be attached to the prosthesis for measurements during everyday lifeis the StepWatch Activity Monitor (SAM)3. This is an advanced step counter that has been used and validated in several studies of amputee activity. The SAM is an ankle worn device that can be calibrated to accurately detect each step taken by the person being measured. The data collected is steps per selected unit of time, and the device can collect measurements for more than three months. A docking station is used to retrieve the data collected, and proprietary software package is used to both set up the unit for measurements and to process the data. There are multiple types of commercial pedometers and step counters available that can as well be used for amputees. These are generally very simple devices that count the number of times the vertical acceleration exceeds a preset value. An estimated average step-length is then used to approximate distance traveled and even energy expenditure. The problems with these devices is that their accuracy can vary greatly from one person to another (6), they do generally not account for varying types of gait, and the end result is often a single step-count number that does not reveal too much about the actual actions of the wearer. Examples of more advanced measurement equipment are the Dynaport ADL-Monitor4, activPAL Tracking System5 and the IDEEA (Intelligent Device for Energy Expenditure & Activity)6. All these devices are aimed at recording different modes of activity, i.e. they can identify whether the person is standing, sitting, lying or ambulating at each interval in time. These depend on varying number of sensors being placed on the person during measurement, and are generally more suited for research than for everyday clinical use. Different computer software suites are used to collect and analyze the information collected, and the amount of information collected allows for the generation of elaborate reports on the activities of the wearer. These devices can measure continuously for up to seven days or more. The activPAL is the simplest of these devices, has all sensors contained in one housing that is attached at the thigh of the person being measured. The position of the device allows for the detection of statue and locomotion, but it is limited to event detection and is unable to determine the details of each step as possible by the Ossur PAM. The last type of devices addressed here are the actigraphs. These are different types of wrist or hip-worn devices that measure acceleration and can thereby provide information on the activity of the wearer. These devices output either a raw acceleration measurement or counts exceeding a given threshold. Examples of such devices are the RT3 Tri-axial Research Tracker7, Vivago WristCare8 and Motionlogger Actigraph Systems9. All these devices are designed to measure general movement of the wearer, i.e. to detect sleep disorders or deviations from baseline activity. These do not collect data specifically related to gait or ambulation, and are thereby of limited interest for measuring lower limb amputees specifically. The possible outcome from different devices and their usefulness varies highly. The correct application of this type of technology is very useful to improve patient care and the information that becomes available gives added insight to the lifeof the patient. Correct measurement of patient activity is invaluable to be able to improve the patient’s quality of life through correct treatment.Karason GG Outcomes Objective Measurement of Patient Activity American Academy of Orthotists and Prosthetists Annual Meeting, Orlando, Florida, USA March 2005, P15 2005. NA.