Mahendran, N
2nd Joint World Congress of ISPGR and Gait and Mental Function
BACKGROUND AND AIM: Many stroke survivors report difficulty ambulating outside the home. Accelerometers have been used to measure general physical activity after stroke, but are unable to separate walking activity completed within the home, from that performed in the community. Additional location information recorded by portable global positioning systems (GPS) may address this issue. However, as stroke survivors walk slowly and asymmetrically, the validity and reliability of these devices need to be confirmed in this group. This study aimed to determine the concurrent validity and retest reliability of two accelerometers (ActivPALTM and Sensewear® Pro2 Armband) and a GPS unit during tasks that reflect community walking and also concurrent validity during free-living community ambulation in people with stroke. METHODS: Fifteen community-dwelling stroke survivors attended 2 sessions and completed a 6-minute walk, treadmill walking at 3 speeds, and a 200 metre outdoor circuit over varied urban terrain while wearing the three devices. The devices collected measures of step counts, time spent walking, distance, energy expenditure and location. Investigators also simultaneously collected measures directly. Participants then wore the devices for four days, to measure free-living community ambulation, with time spent walking and location compared with a self-report activity diary. Intraclass correlation coefficients (ICC), Bland-Altman plots and absolute percentage of error (APE) were used to determine validity and reliability of all measures. RESULTS: ActivPALTM had excellent concurrent validity for time spent walking, (ICC > 0.997, APE <3.1%) and most episodes of step count (ICC >0.855, APE < 5.6%) and excellent retest reliability for step counts, time spent walking and energy expenditure (EE) measures during all walking tests (ICC > 0.872, APE < 6.5%). Sensewear had missing values for 21% of recordings and a high APE (>21.9%) for all measures. The GPS demonstrated excellent validity and reliability in time spent walking and step count (ICC > 0.926, APE < 8.5%) but was not accurate for distance (ICC = - 0.085, APE = 23.9%). During the outdoor circuit, the GPS was consistently accurate for start and stop location points, but not for the route taken. All devices had a high APE (> 44%) during free-living community ambulation, possibly due to poor accuracy of self-report activity diaries, except for GPS location data, which was accurate for 88% of all community walking trips. CONCLUSIONS: ActivPALTM and the GPS together appear appropriate to measure community ambulation after stroke. Further investigation of the accuracy of GPS to measure over longer distances is required. Sensewear algorithms specific to stroke may improve its accuracy for community ambulation measurement.Mahendran, N Validity and reliability of accelerometers and GPS to measure community ambulation after stroke 2nd Joint World Congress of ISPGR and Gait and Mental Function 2013. NA.