Validation of activPAL™ Activity Monitor as a Measure of Step Count During the Timed Up-and-Go (TUG) and Ten-Metre Walk (TMW) Tests

January 2011

Choo, PL; Crowther, I; Richards, H; Sugavanam, T; F, van Wijck

2011 ICAMPAM

Introduction: The activPALTM is a commonly-used activity monitor, but there is a lack of published research establishing its validity in people with stroke. Prior to testing the validity of activPALTM in stroke, a pilot study with healthy participants was undertaken. Activities comprised sitting, standing and walking, as specified in the Timed Up-and-Go (TUG) and Ten-Metre Walk (TMW) test protocols, which are reliable and widely-used in stroke rehabilitation. The aim of the study was to evaluate the test-retest reliability and concurrent validity of activPALTM in measuring step count during TUG and TMW, using video observation as criterion standard. Methods: Fifteen healthy Queen Margaret University students (13 females, 2 males; age 22.7±2.1 years) were video-recorded in the laboratory undertaking six trials of TUG and TMW with activPALTM, which recorded continuously for the entire day’s data collection. Test order was randomised using electronic die and repeated the following week. Results: of independent video observation of step count by three researchers were compared to activPALTM data. Inter-observer and test-retest reliability were calculated using intraclass correlation coefficients (ICC) with standard error of measurement (SEM). Concurrent validity was determined using Bland and Altman 95% limits of agreement (LOA). Results: Inter-observer reliability of video observation was perfect (ICC(2,3)=0.99) with an acceptable level of precision for TUG (SEM=0.13) and TMW (SEM=0.17)[1]. For TMW, test-retest reliability of activPALTM was substantial (ICC(2,1)=0.77) with an acceptable level of precision (SEM=0.73 steps). Regarding concurrent validity, level of agreement was low between activPALTM and video observation: mean step count difference between activPALTM and observation was -3.34 steps (upper LOA=0.94 steps; lower LOA=-5.74 steps). For TUG, reliability and validity of activPALTM could not be determined as no step count was registered. Mean completion times for TUG and TMW were 9.33s and 11.87s respectively. Discussion: AND CONCLUSION The results from this study indicate that the activPALTM was not valid in measuring step count during TUG and TMW. Given that activPALTM requires a 10-second sampling period to register an activity, activPALTM data require interpretation with caution where activity durations approximate the sampling period. High reproducibility of data from video observation corroborates its use as criterion standard.

http://www.umass.edu/sphhs/documents/ConferencebookICAMPAM2011.pdf

Choo, PL; Crowther, I; Richards, H; Sugavanam, T; F, van Wijck Validation of activPAL™ Activity Monitor as a Measure of Step Count During the Timed Up-and-Go (TUG) and Ten-Metre Walk (TMW) Tests 2011 ICAMPAM 2011. http://www.umass.edu/sphhs/documents/ConferencebookICAMPAM2011.pdf.