Personalised foot orthotics with embedded temperature sensing: proof of concept and correlation with activity

January 2012

Telfer, S; Munguia, J; Pallari, J; Dalgarno, K; Woodburn, J

ISPO UK MS 40th Anniversary Meeting

The ability to monitor physiological and mechanical parameters relating to the foot over extended time periods is of potential interest for a number of clinical conditions. For example, the ability to detect the early signs of plantar ulcer development in patients with peripheral neuropathies could be highly beneficial for this highly prevalent and difficult to treat problem. The in-shoe environment is however a challenging environment for long term repeated measurements, primarily because of a combination of cyclic high loading patterns and varying temperature and humidity levels [1, 2]. The aim of this study was to test a novel foot orthotic (FO) design featuring embedded temperature sensors and to determine if the measurements taken by the device could be correlated with activity levels. Ten healthy participants (5♀) gave informed consent to take part in this study. A pair of customised FOs were designed from weight bearing 3D surface scans of the participant’s feet using OrthoModel software (Delcam, Birmingham, UK). The designs were then modified to include attachment sockets for temperature sensors with built in data loggers, (Thermochron iButton®, Maxim Integrated Products, San Jose, CA, USA) positioned to measure plantar surface temperature under the medial arch, and below the FO to measure ambient shoe temperature. All devices were then manufactured in Nylon 12 via selective laser sintering (Peacocks Medical Group, Newcastle, UK). Participants wore the temperature sensor FOs and an activity monitor (ActivPAL; PAL Technologies Ltd, Glasgow, UK) over the course of four consecutive days. After collection, the data was randomly partitioned into equal sized training and validation sets and a threshold algorithm developed to identify time periods of high activity from temperature data. T-tests were performed for both datasets to compare energy expenditure levels at time periods identified as low and high activity. All FOs performed in a reliable manner over the course of the test period. The average energy expenditure during periods identified as high activity from the temperature data was 2.23 and 2.43 MET/hr for the training and validation datasets respectively, compared to 1.49 and 1.59 MET/hr for low activity time periods, with differences shown to be statistically significant (training set p<0.001, validation p<0.001, and overall p<0.001). These results provide preliminary evidence that FOs featuring embedded temperature sensing can be used to identify time periods of high activity in healthy individuals and may be useful as a tool for measuring compliance. Embedding sensors in an FO is an appealing option as these devices can be used in multiple sets of footwear without the requirement for any non-reversible modifications to the footwear itself. Further work is required to determine if the devices could be applied in a population with peripheral neuropathy, and ultimately as a measure to detect localised inflammation.

http://www.ispo.org.uk/pdf/ISPO UK 40th Compendium – Final Copy.pdf

Telfer, S; Munguia, J; Pallari, J; Dalgarno, K; Woodburn, J Personalised foot orthotics with embedded temperature sensing: proof of concept and correlation with activity ISPO UK MS 40th Anniversary Meeting 2012. http://www.ispo.org.uk/pdf/ISPO UK 40th Compendium – Final Copy.pdf.