Hawari NSA, McMichan L, Martin G, Wongpipit W, Gill JMR
BASES Conference 2014; J Sports Sci 32 (S2) : 28 – 32; Epub 14 November 2014
Accelerometers provide the potential for accurate objective measurement of physical activity, which is important for the epidemiological assessment of activity levels and the association with disease risk and for the quantification of changes in activity behaviour in response to interventions. Hip and thigh are commonly used locations for accelerometer placement. However, it is unclear whether these two locations are comparable in terms of measurement of stepping rate, speed and exercise intensity. The purpose of this study was to compare the effects of hip and thigh accelerometer placement on the measurement of stepping rate, speed and exercise intensity at a range of walking speeds. With ethical approval 23 apparently healthy adults (13 female), aged 19 42 years participated. ActivPAL accelerometers (Pal Technologies, UK) were affixed to the participants left thighs (10 cm above the knee) and left hips to record body accelerations. Participants walked on a treadmill for 5 min at each eight different speeds (1 8 km h?1). Expired air samples were collected for the determination of oxygen uptake, and these activities were video recorded to determine the actual stepping rates. ActivPAL professional software (v7.1.25) was used to calculate the stepping rates. The vector magnitude of sum of changes in raw accelerations in the x, y and z directions per second, smoothed over a 10-s interval, was used to summarise the acceleration profile for each speed. The hip-placed accelerometer was unable to count steps at 1 km h?1 (100 0% underestimation (mean s)) and underestimated stepping rate by 91 15% and 17 11% at 2 and 3 km h?1, respectively. For speeds ?4 km h?1, the hip-based accelerometer underestimated stepping rate by 7 10%. The thigh-placed accelerometer underestimated stepping rate by 49 28% at 1 km h?1, but at speeds ?2 km h?1 underestimated stepping rate by 4 11%. Quadratic regressions were used to quantify the relationship between acceleration profile and speed/oxygen uptake for the hip and thigh positions. Model fits were comparable for both the positions, with acceleration profile explaining ~99% of the variance in speed and oxygen uptake for both the hip and the thigh accelerometer placement. In conclusion, thigh-based accelerometer placement provides advantages over hip-based placement for the quantification of stepping rate at slow speeds. This may have implications for step counting during light incidental activities of daily living. However, when using raw acceleration profiles to quantify speed and exercise intensity, hip and thigh accelerometer placement was comparable.Hawari NSA, McMichan L, Martin G, Wongpipit W, Gill JMR Determining stepping rate, speed and exercise intensity using a triaxial accelerometer: effect of accelerometer position BASES Conference 2014; J Sports Sci 32 (S2) : 28 – 32; Epub 14 November 2014 2014. http://www.tandfonline.com/doi/full/10.1080/02640414.2014.968381#.VG4Bw3kqWUk.