Kringen, Nina L.; Healy, Genevieve N.; Winkler, Elisabeth A. H.; Clark, Bronwyn K.
Measurement in Physical Education and Exercise Science
This study examined the accuracy of self-attachment of the activPAL activity monitor. A convenience sample of 50 participants self-attached the monitor after being presented with written material only (WMO) and then written and video (WV) instructions; and completed a questionnaire regarding the acceptability of the instructional methods. Participants positioned the monitor lower than the instructed position on the thigh (WMO −5.15 ± 2.75 cm, WV −4.16 ± 2.15 cm; p = .008 difference) and approximately 2 cm laterally from the thigh midline (WMO 1.90 ± 0.92 cm; WV 2.08 ± 1.24 cm). The orientation of the device was positioned correctly along the midline (within < 1° of vertical). Acceptability was high for both instructional methods although preference was shown for the WV instruction. In conclusion, participants consistently self-attached the activPAL close to the intended placement with either instructional method. The addition of video instruction produced a slightly more accurate attachment and was preferred by the participants.
Kringen, Nina L.; Healy, Genevieve N.; Winkler, Elisabeth A. H.; Clark, Bronwyn K. Accuracy of activPAL Self-Attachment Methods Measurement in Physical Education and Exercise Science 2016. http://www.tandfonline.com/doi/full/10.1080/1091367X.2016.1189916.