Comparison of the accuracy of the ActivPAL activity monitor, the Actigraph GT1M activity monitor and the Actigraph GT3X activity monitor during activities of daily living

Tracey, S

NA

Comparison of the accuracy of the ActivPAL activity monitor, the Actigraph GT1M activity monitor, and the Actigraph GT3X activity monitor during activities of daily living Sinead Tracey and Andrew Grainger Department of Physiotherapy, Queen Margaret University, Edinburgh Introduction: The aim of this study was to investigate if the activPAL activity monitor, the actigraph GT1M and the actigraph GT3X are accurate measures of step count, energy expenditure and activity detection during activities of daily living. Observation was used as the criterion measure for step count and activity detection. Energy expenditure was compared against the valid actigraph GT1M and predicted energy expenditure values. Methods: Eighteen healthy students, age ranging from 20-28 participated in the study. Participants attended one data collection session, which required the participant to complete an activity circuit while wearing all three activity monitors. The circuit involved lying, sitting, standing, walking on a treadmill, cycling and walking up and down stairs. Direct observation was used to tally the step count for the circuit and detect activity with the assistance of a camcorder. Upon completion of the circuit, data output was collected from each of the activity monitors and then analysed. All three activity monitors were compared against observation to measure step count. The actigraph GT3X and activPAL were compared against the actigraph GT1M and predicted energy expenditures to assess energy expenditure measurements. The actigraph GT1M and the activPAL were compared against observation to assess activity detection. Results: Results indicated the activPAL to be an accurate method of measuring step count in comparison to observation with a high correlation of r= 0.887 and a low mean percentage step count error of 5.53%. Results indicated that both actigraph monitors were not accurate against observation at measuring step count, with the GT1M and GT3X having mean percentage step count errors of 27.48% and 32.92% respectively. Energy expenditure results show that the activPAL (average met per min = 3.35) overestimated energy expenditure, while the actigraphs (GT1M = 0.987 Mets and GT3X = 0.898 Mets) underestimated energy expenditure compared to predicted energy expenditure results of 2.5 mets per min. The activPAL had low percentage errors when measuring time spent sitting (-7.25%), time spent standing (13.52%) and time spent stepping (-6.67%) in comparison to observation. The actigraph GT3X was unable to accurately detect positional information, and would be deemed unreliable at measuring inclinations according to the findings of this study. Conclusion: Overall the activPAL showed consistency at measuring step count and activity detection but further research is needed to assess energy expenditure measurements. Both actigraph monitors did not display accuracy at measuring step count, energy expenditure or activity detection and further research is required to identify the source of these errors.

NA

Tracey, S Comparison of the accuracy of the ActivPAL activity monitor, the Actigraph GT1M activity monitor and the Actigraph GT3X activity monitor during activities of daily living NA 2010. http://etheses.qmu.ac.uk/396/.