Validity of a body worn sensor system as a measure of step count during walking in frail older adults

Stene, G; Taraldsen, K; Bjåstad, KG; Einarsen, E; Askim, T; Indredavik, B; Sletvold, O; Helbostad, JL

1st International Conference on Ambulatory Monitoring of Physical Activity and Movement

INTRODUCTION New technology has made it possible to objectively measure gait by use of small body worn sensors. So far such systems have only been validated in healthy persons and patient groups with slightly reduced walking capacity. Frail older adults are characterised with asymmetric and slow walking speed. The aim of this study was to test the recognition and accuracy of step count of a uni-axial accelerometer in frail older adults against video recordings. METHODS A cross sectional comparative study design was used. The sensor (ActivPAL®) was used to count steps in 10 participants (5 inpatients from geriatric unit and 5 from stroke unit). This was the first 10 out of a total of 45 participants (complete data analysis to be finalised in February 2008); 5 women: mean age 87 ±3,16 yrs and 5 men: mean age 72,2 ±5,17 yrs. The Active PAL sensor was attached to the participants’ right thigh. All participants used their usual walking aid during testing. 6 needed additional support. Participants walked back and forth on a 5m level surface at three instructed slow, preferred and fast walking speeds, in addition to three 4 steps and three 8 steps walking sequences. Step count derived from the ActivPAL sensor was compared with observations based on 2D video camera recordings. Absolute percentage of agreement was calculated using the Bland Altman method. Absolute percentage error of step count was calculated as ((sensor – observation)/observation) x 100). RESULTS Mean slow speed was 0,32 ± 0,06 m/s, preferred was 0,46 ± 0,86 m/s and fast speed was 0,66± 0,10 m/s. Table 1 and figure 1 demonstrate low agreement between video observations and step count from the ActivPAL sensor. The error was largest for the slowest instructed walking and the shortest sequences. CONCLUSION The results from this small sample indicate problems with using the ActivPAL sensor for step count measurement in frail older adults using walking aids while walking short distances. This population is characterised by walking short walking distances at a slow speed, hence it is important to develop robust methods for recognising gait in these individuals.

NA

Stene, G; Taraldsen, K; Bjåstad, KG; Einarsen, E; Askim, T; Indredavik, B; Sletvold, O; Helbostad, JL Validity of a body worn sensor system as a measure of step count during walking in frail older adults 1st International Conference on Ambulatory Monitoring of Physical Activity and Movement 2008. http://www.umass.edu/sphhs/documents/ConferencebookICAMPAM2008.pdf.