Tang, K; Stansfield, BW; Spence, WD; Simpson, D; Maxwell, D
12th World Congress of the International Society for Prosthetics and Orthotics
INTRODUCTION Amputation causes physical disability and prosthetic devices are used to restore the mobility of the individual. Observations and gait analysis may be carried out in gait laboratory environment to determine gait quality; and questionnaires may be used to find amputees’ daily activity levels. However, there are a lack of monitoring devices for application in a free-living environment, which can quantify the prosthetic wearing times as well as amputee activity levels. A method of using a pressure monitor for quantifying the wearing time and activity levels for lower limb amputees using suction sockets was developed. The pressure monitor was produced by PALtechnologies Limited (Glasgow, UK), the activPAL pressure monitor comprises a piezoresistive pressure transducer, microprocessor, recording element, associated electronics and power supply. It was lightweight of approximately 20g with dimensions of 50x50x7mm. A range of sampling frequency 0-100Hz is available, and 10Hz was used for this study giving a maximum recording period in excess of one month. METHOD Subjects: Subjects, aged 45-65, with mature unilateral transtibial amputations. Apparatus: Suction sockets were custom made to fit each individual. The activPAL pressure monitor was attached to the suction valve of the socket. Procedures: The study was carried out at the gait laboratory, Bioengineering Unit at the University of Strathclyde, UK. Prior to data collection, ethical approval was granted through the University Ethics Committee. The subjects were asked to don their prosthesis in their usual manner and performed activities such as sitting,standing, walking on level ground, climbing up and down stairs and doffing the prosthesis. Data Analysis: Each session was video recorded and compared with the collected pressure profiles from the pressurePAL. RESULTS AND DISCUSSION Figure 1 shows an example of the pressure profile recorded by the pressurePAL connected to the suction valve of a transtibial socket while the subject performed different activities. The zero line represents atmospheric pressure and values below this line indicate the system was in vacuum and values above the atmospheric pressure indicate a positive pressure was being applied to the system. The results indicated that during the doff state, the pressure level remained at atmospheric pressure which was expected as there was no load inside the socket. During don, both large compression and suction values occurred as the subject tried to push all the air out of the socket. The data showed cyclical signals during the walking phases, and the number of steps corresponded to the number of cycles in the data with 95.6% accuracy for step detection. The double peaked waveforms during both the stance and swing phases were shown in some subjects, but not all due to the differences in the amputees’ gait patterns. Quiet periods of standing and sitting sometimes gave a constant signal similar to the doff state. The only way to identify these periods from the doff state was to identify if the prosthesis had been donned since the last doff instance. The continuous recording of pressure profiles allowed this analysis to be successfully conducted at the post-processing stage. CONCLUSION This study showed that a pressure monitor could be used to reliably quantify stepping activities. Further work is required to explore the potential for identifying other states (standing, sitting and doff) by characterising the typical pressure profile of each state.Tang, K; Stansfield, BW; Spence, WD; Simpson, D; Maxwell, D The quantification of lower limb prosthetic wearing times and amputees’ activity levels when using suction sockets 12th World Congress of the International Society for Prosthetics and Orthotics 2007. NA.