Comparison of Active style Pro HJA-350IT, ActiGraphTMGT3X+ and activPAL3c in assessing sedentary behavior

Kurita S, Yano S, Shibata A, Ishii K, Oka K

ISBNPA 2015: International Society of Behavioral Nutrition and Physical Activity, Edinburgh, UK 3 – 6 June 2015 (P3C.183, p 632)

Objective: Active style Pro HJA-350IT (ASP) is a relatively new accelerometer which has high validity for estimating low intensity physical activity including sedentary behavior. There is limited research comparing the ASP s output to other accelerometers used in the large number of previous studies to assess sedentary behavior. It is of interest to know whether the different accelerometers give similar information about volume and patterns of sedentary behavior. The purpose of the present study was to compare the outputs of ASP, ActiGraghTMGT3X+ (GT3X+), and activPAL3cTM (AP) in assessing sedentary behavior under freeliving conditions. Methods: Thirty four healthy workers (21 males and 13 females, 41.1 13.0 years old) wore ASP, GT3X+, and AP simultaneously more than 10 hours during waking time on a work day and a non-work day. Sedentary behavior was defined <100 counts/min in GT3X+, 1.5 metabolic equivalents/min in ASP and code of sitting/lying 1 or more minutes in AP. The difference and agreement in outputs of total sedentary time were analyzed by ANOVA, intra class correlation coefficients (ICC 2.1) and Bland-Altman plots. The outputs of AP were used as criterion. Results: Total sitting time on work day and non-work day measured by AP were 455.5 130.0 min and 543.5 163.3 min, respectively. Comparing outputs on work day, GT3X+ overestimated 46.5 min (95%CI=18.4, 74.7) but ASP underestimated 30.4 min (95%CI=- 56.1, -4.8). On non-work day, ASP and GT3X+ showed no significant differences compared with AP but GT3X+ measured 35.6 min (95%CI=14.3, 57.0) longer than ASP. The ICC between ASP and AP was higher than between GT3X+ and AP on both days (work day: 0.889 vs. 0.837; non-work day: 0.926 vs. 0.921). Bland-Altman Plots indicated proportional bias between GT3X+ and AP on work day (r=-.362, p=.039). Conclusions: The present study demonstrates that GT3X+ overestimates sitting time but ASP underestimates against AP. These tendencies, especially in GT3X+, are more obvious when standing time is relatively long. ASP is superior to GT3X+ in assessing total sedentary time probably because the ability of ASP to measure low intensity physical activity is high.

NA

Kurita S, Yano S, Shibata A, Ishii K, Oka K Comparison of Active style Pro HJA-350IT, ActiGraphTMGT3X+ and activPAL3c in assessing sedentary behavior ISBNPA 2015: International Society of Behavioral Nutrition and Physical Activity, Edinburgh, UK 3 – 6 June 2015 (P3C.183, p 632) 2015. https://www.isbnpa.org/files/annual_meetings/2015/06/10/16/attachments/557869344fefe.pdf.