Baer, G; O’Loughlin, H
World Congress of Physiotherapy
PURPOSE: This study aimed to investigate the levels of agreement between three clinical methods of measuring step count. The tools under investigation were a pedometer (Yamax Digiwalker SW-200), a new physical activity monitor (ActivPalTM) and video observation (used as the criterion standard). RELEVANCE: Regular physical activity is associated with improved physical and mental health. Measures of step count are commonly used to infer levels of physical activity. One commonly cited recommendation to ensuring an appropriate level of physical activity is taking 10,000 steps per day (Hatano et al 1993), however valid and practical methods of measuring physical activity can be problematic. The step count measurement methods require to be accurate and robust for routine clinical use over prolonged periods and for diverse activities. PARTICIPANTS: Twenty healthy subjects were recruited (4 male, 16 female, mean age 24.8 + 2.6 years). Ethical approval was received from Queen Margaret University College, Edinburgh. METHODS: Pilot work was undertaken to determine the study protocol and exact location of pedometers and activPal. Subjects wore two pedometers (one on each leg) and an activPal on the dominant (Dom) leg for one free-living day. During the day each subject participated in a 30 minute trial of treadmill walking at 2.5 kilometres per hour(km/h), 5 km/h and jogging at 7.5 km/h. The treadmill trial was video recorded to provide a criterion measure of step count. ANALYSIS: Data were checked for normality of distribution using Shapiro-Wilkes test. Levels of agreement between methods were assessed using the Bland & Altman method (Bland & Altman 1986), calculated as the difference in step-count between two methods plotted against the mean of both. Percentage errors in step count were also calculated for pedometer and activPal against criterion video observation. RESULTS: The pedometers demonstrated poor levels of agreement with observation and large error in step count at 2.5 km/h (mean error (ME) −21% non-dominant (non-Dom) leg, and ME −33 Dom). Pedometers showed very good levels of agreement with observation at both 5 km/h (ME +0.8% non-Dom, and ME +0.18% Dom) and at 7.5 km/h (ME = +0.03% non-Dom and ME −0.05% Dom). ActivPal had very good levels of agreement with observation at 2.5 km/h (ME −0.42%) and 5 km/h (ME −0.15%) but showed poor agreement with observation at the higher velocity of 7.5 km/h (ME +18.2%). CONCLUSIONS: Results indicated that the Yamax SW-200Pedometer is a suitable tool for measuring step count in populations that ambulate at >5 km/h or whose activities include regular jogging at 7.5 km/h. At velocities of 2.5 km/h and 5 km/h activPal appears a more appropriate means of measuring step count. Data obtained with the Yamax pedometer at a velocity equivalent to 2.5km/h and the activPal at velocity of 7.5km/h should however be viewed with extreme caution. IMPLICATIONS: When measuring step count as an indication of physical activity, therapists need to take into account likely walking speed and select the appropriate measurement tool for the population under investigation.Baer, G; O’Loughlin, H Stepping out: an investigation into the level of agreement between three measures of step count World Congress of Physiotherapy 2007. http://www.wcpt.org/abstracts2007/Abstracts/2849.htm.