Rubin, Daniel Steven; Straczkiewicz, Marcin; Yamamoto, Emi; Madariaga, Maria Lucia L.; Ferguson, Mark; Brach, Jennifer S.; Glynn, Nancy W.; Lee, Sang Mee; Danilovich, Margaret; Huisingh-Scheetz, Megan
Digital Biomarkers
Background: Preoperative physical functional assessments (i.e., assessments that measure capability to perform physical activity) are integral to estimate perioperative risk for older adults. However, these assessments are not routinely performed in-clinic prior to surgery. Walking cadence, or the number of steps walked in a specified amount of time (i.e., steps/min), measures activity intensity and may be able to identify high-risk patients prior to surgery. Smartphones can measure walking characteristics and guide patients through remote functional assessments. Here we assess feasibility, acceptability and accuracy of Walk Test, a smartphone application designed to measure walking cadence.
Methods: We performed a prospective cohort study of older adults prior to abdominal surgery and enrolled them remotely to perform at-home usual and fast-paced walks with subsequent validation in-clinic. Each walk (usual and fast-paced) was 2-minutes in duration. Feasibility was assessed if 80% of patients could perform all study procedures, acceptability was measured using the Post-Study Survey Usability Questionnaire (PSSUQ); accuracy of our approach was assessed with Lin’s Concordance Coefficient (CCC). activPAL thigh worn accelerometer worn during the in-clinic walk served as a gold standard comparison. We used the CCC to compare the at-home and in-clinic walks as performed by Walk Test.
Results: We enrolled 41 participants (mean age 69±5 years, 26 (63%) female); 88% (36/41) successfully completed entire study protocol including independent installation of the application, walk tests (at-home and in-clinic) and questionnaires. Median (IQR) overall score of PSSUQ was 1 (1, 1) indicating strong acceptability and usability. The Lin’s CCC between the in-clinic activPAL and Walk Test for usual pace walk was 0.97 (95% CI: 0.96, 0.99, p <0.001) and for fast pact walks 0.96 (95% CI: 0.93, 0.98, p <0.001). The CCC between the at-home and in-clinic walks for usual pace walks was 0.70 (95% CI: 0.53, 0.86) and for fast-pace walks was 0.46 (95% CI: 0.21, 0.72).
Conclusion: We successfully demonstrated the feasibility, acceptability and accuracy of Walk Test to measure walking cadence. Future work is needed to standardize walk test performance at-home to ensure consistency between in-clinic and at-home measures.
Rubin, Daniel Steven; Straczkiewicz, Marcin; Yamamoto, Emi; Madariaga, Maria Lucia L.; Ferguson, Mark; Brach, Jennifer S.; Glynn, Nancy W.; Lee, Sang Mee; Danilovich, Margaret; Huisingh-Scheetz, Megan A smartphone application to measure walking cadence before major abdominal surgery in older adults. Digital Biomarkers 2025. https://doi.org/10.1159/000545982.