Fawole, Henrietta O.; Obiakalusi, C. A.; Idowu, O.A.; Adandom, I.I.; Osuji, P.O.; Nwabudike, C.O.; Ehiabhi, C.H.; Obode, D.O.; Ogedegbe, E.P.; Uwabor, A.; Imouokhome, O.A.; Osadiaye, O.A.; Eromosele, B.; Akinrolie, O.
ISBNPA 2026
Purpose: Affordable step-counting tools are vital for promoting physical activity in low- and middle-income countries (LMICs) where access to objective activity monitors is limited. This study compared the Omron pedometer and ActivPAL accelerometer against a criterion step count across walking speeds in obese and non-obese Nigerian adults to assess their validity for population-level monitoring in resource-limited settings. Methods: Thirty-two female university students (20 obese, 12 non-obese) completed treadmill trials at 1.9 m/s, 3.7 m/s, and preferred walking speed (PWS). Step counts (steps per minute, spm) from the ActivPAL accelerometer and Omron pedometer were compared against a criterion reference (mean of hand tally and video counts). Agreement between each device and the criterion was assessed using Bland-Altman analysis to estimate bias (mean difference), 95% confidence intervals, and limits of agreement (LOA) across walking speeds and BMI groups. Results: Participants (mean age = 22.1 ± 1.0 y; BMI = 32.0 kg/m², IQR = 11.3) were classified as obese (27.7-37.2 kg/m²) or non-obese (19.0-23.7 kg/m²). Bland-Altman analysis showed the ActivPAL consistently underestimated step counts across speeds with smaller, more stable errors than the Omron pedometer. At PWS, biases were -14.5 spm (95% CI: -17.4 to -11.6; LOA: -23.1 to -5.9) [non-obese] and -2.7 spm (95% CI: -8.8 to 3.4; LOA: -31.3 to 26.0) [obese] for the ActivPAL, versus +7.5 spm (95% CI: 4.9 to 10.0; LOA: -0.1 to 15.1) [non-obese] and +5.9 spm (95% CI: -4.2 to 16.0; LOA: -41.4 to 53.2) [obese] for the pedometer. Across speeds, pedometer biases were -24.5 spm (95% CI: -32.2 to -16.7; LOA: -61.0 to 12.1) at 1.9 m/s, -0.5 spm (95% CI: -6.8 to 5.9; LOA: -30.2 to 29.3) at 3.7 m/s, and +5.9 spm (95% CI: -4.2 to 16.0; LOA: -41.4 to 53.2) at PWS, demonstrating greater error variability than the ActivPAL. Conclusion: The ActivPAL showed more consistent agreement with the criterion across walking speeds and BMI groups, while the Omron pedometer exhibited greater variability, particularly among obese participants. These findings support the ActivPAL as a more reliable step-counting tool for research and public health applications in low-resource settings.
https://isbnpa2026.abstractserver.com/program/#/details/presentations/558
Fawole, Henrietta O.; Obiakalusi, C. A.; Idowu, O.A.; Adandom, I.I.; Osuji, P.O.; Nwabudike, C.O.; Ehiabhi, C.H.; Obode, D.O.; Ogedegbe, E.P.; Uwabor, A.; Imouokhome, O.A.; Osadiaye, O.A.; Eromosele, B.; Akinrolie, O. Validation of Step-counting Devices across Walking Speeds in Obese and Non-obese Nigerian Adults2026 – Program NA 2026. https://isbnpa2026.abstractserver.com/program/#/details/presentations/558.