McAloon, M
12th World Congress of the International Society for Prosthetics and Orthotics
INTRODUCTION During the last decades it has become clear that the functional consequences of a given disease or disorder were the key-elements that needed to be treated and not the medical diagnosis (Helders 2001). The measurement of function is therefore paramount and requires the development of valid and reliable instruments. A literature search has been carried out to reveal existing methods of activity monitoring and measuring outcomes used within cerebral palsy studies. A validation study for a novel activity monitor, the activPAL has been undertaken, with the intent that this may provide a reliable and valid tool for future research and increase evidence based practice within the area of CP For the small population within the pilot validation study it was found that the activPAL activity monitor was a suitable tool to be used with type 2 classification patterns (Winters T and Gage J 1987) of cerebral palsy METHOD Subjects: Children with type 2 hemiplegia gait patterns (Winters and Gage 1987) as a result of Cerebral Palsy. Apparatus: Hardware: activPAL activity monitor; Monitor docking station; Monitor ‘stickies’; Stop watch; Laptop; Digital video camera with on screen timer; Designated activity course area. Software: SPSS statistical software; activPAL data software; Microsoft excel software. Procedures: A method comparison study involved the direct comparison of readings taken by the activity monitor against observations analysed from a video recording taken at that time. The procedure adopted has been used in previous validation studies for activity monitoring devices (Walker et al 1997). Data Analysis: The processing of the data was carried out using SPSS statistical software. Correlation and t-tests were undertaken on all the activity data to determine reliability and validity. Intra rater results were carried out on the data obtained from the observers. RESULTS The activPAL activity monitor was found to be valid and reliable for the measurement of the number of steps taken, t(14)=-1.780, p<0.097; the time spent sitting, t(9)=0.429, p<0.678; the time spent standing, t(4)=-0.38, p<0.678; and the time spent walking, t(4)=-0.73, p<0.477. DISCUSSION The less developed cognitive skills of the child results in a lesser ability to effectively use self report questionnaires (Welk 2000). The activPAL monitor requires no reliance upon the subject’s cognitive skills and as such is suitable for children or other subjects where cognitive ability may be affected. Children with lower limb disabilities will potentially have a slower walking speed. Normal walking cadence is between 80 - 150 steps per minute (Whittle 2002). The results from the participants fall without these bounds, between 45.4 and 58.5 steps per minute. The resultant reduction in cadence that is present in the children with type 1 hemiplegia within this study has been shown not be a source of error when using the activPAL monitor and supports earlier unpublished data (Kenney L, Mickelborough J 2001) that the activPAL activity monitor is not affected to any great degree by reductions in the levels of cadence. Previous methods of measuring activity levels have had flaws within them that preclude them from measuring across the whole age range of children. The monitor does not exhibit any ceiling or floor effect as exhibited by the GMFM. The deployment of the activPAL monitor results in no such methodological weakness in this respect. Conventional activity assessments such as the CARS (Childrens Actvity Rating Scale) are costly due to the deployment of health care professionals as observers of activities. Lengthy and costly observation is not required from the healthcare professional when using the activPAL monitor. It may be used as a research tool and to provide data to facilitate outcome measurement within audit procedures. CONCLUSION The activPAL activity monitor was found to be a valid and reliable tool when measuring the activity of type 2 hemiplegic gate resultant from cerebral palsy.McAloon, M A pilot study to validate an activity monitor for use with cerebral palsy 12th World Congress of the International Society for Prosthetics and Orthotics 2007. NA.