Ridley, K; Salmon, J; Ridgers, ND
3rd International Conference on Ambulatory Monitoring of Physical Activity and Movement
INTRODUCTION: Emerging evidence associating sedentary behaviour with health and academic outcomes has drawn attention to the time children spend sitting. Activity monitors are commonly used to measure MVPA in children, yet there are few studies investigating their validity when measuring sitting time, in particular the ability to distinguish between sitting, standing and stepping. As children spend a large proportion of their days in classrooms, school is a setting of interest. PURPOSE: The purpose of this study was to validate the ActivPAL (APal) and ActiGraph 3GTX (AG) activity monitors for measurement of sitting against a criterion measure of direct observation (DO). METHODS: 40 children in grades 5, 6 & 7 wore APal inclinometers and AG accelerometers while being video recorded during 2 school lessons (80 total observations; mean duration of lesson = 36.3 min). Teachers nominated two classroom lessons for observation, one typically involving a high prevalence of sitting, and another where more movement around the classroom was permitted. Teachers undertook normal practice in both lessons with no intervention from researchers. Videos were subsequently reviewed and continuous DO data collected using Dartfish event tagging software. APal and AG data were collected in 15 second epochs. Individual participant DO and APal data were recorded as periods of lying, sitting, standing and stepping then summed for each observed lesson. AG data were converted into minutes spent sitting using a cut point of below 25 counts per 15 sec, chosen to correspond to the commonly cited sedentary cut point of 100 counts per min. RESULTS: All three measures of sitting were highly correlated (DO vs APal: r = 0.90, p<0.001; DO vs AG = r = 0.76, p<0.001; APal vs AG = r = 0.72, p<0.001). Bland-Altman analyses of agreement (accounting for two observations per individual) revealed the APal and AGraph underestimated sitting time by 5.1% (bias = -1.85 min, 95% LoA = -8.96 to 5.26 min) and 8.8% (bias = -3.19 min, 95% LoA = -13.08 to 6.70 min) respectively. CONCLUSION: These analyses suggest the APal is more accurate than the AG, when using a cut-point of 100, for assessing sitting time in children in classroom settings where the prevalence and duration of sitting is high. Further studies should seek to validate the APal and AG in settings with greater inter- and intra-individual variation in movement patterns and also evaluate different AG cut-points for assessing sitting.Ridley, K; Salmon, J; Ridgers, ND Validation Of The Activpal And Actigraph For Assessing Sitting In A School Classroom Setting 3rd International Conference on Ambulatory Monitoring of Physical Activity and Movement 2013. http://www.umass.edu/sphhs/sites/default/files/ICAMPAM_Slide_Poster_Composite_6.6.pdf.